background image

 

 

 

PSP24010 

PSP 24V/1A PoE desktop power supply 

 

 

               

 Edition: 1 from 28.12.2011 

 

EN 

 

 

Features of the power supply unit: 

 

 

power output 24VDC/1A 

 

universal input  voltage range 

90÷264VAC 

 

 

high efficiency 75

%

 

 

Data and Power carried over one Ethernet 
Cable 

 

LED optical signalization  

 

protections: 

 

SCP short-circuit protection 

 

overvoltage protection  (AC input) 

 

overload (OLP) 

 
1. Technical description. 

 

1.1. General description. 

        Stabilized  DC  power  supply  is  intended  for  supply  any  LAN  devices  through  Ethernet  Cable,  which  require 
stabilized  voltage  of  24  V  DC.  The unit  provide  power  through  4/5pins(+)  and  7/8pins(-)  in  Ethernet  cable  that 
according to the Ethernet standard are not  used to transmit  data (data communication is made  using  pairs: 1/2 and 
3/6). The Power supply can’t be used in Gigabit Ethernet! The unit is protected against short-circuit and overload. 

 

1.2.  Technical parameters. 

Supply voltage 

90 ÷ 264 V AC 50Hz 

Current consumption 

0,25A@230VAC max. 

Supply power 

24W max. 

Efficiency 

75% 

Output voltage 

24V DC 

Output current 

1,0 A 

Output current t

AMB

<30°C 

1,0 A - refer to graph 1. 

Output current t

AMB

=40°C 

0,7 A - refer to graph 1. 

Ripple voltage 

100mV p-p max. 

Short-circuit protection SCP 

electronic, automatic recovery 

Overload protection OLP 

105-150% of power supply, automatic recovery 

Optical signalization 

Power – presence of DC voltage, changing color over approx. 
80% of nominal output current 
LAN – presence of LAN network 

Operation conditions                                            

temperature 0 

o

C÷40

 o

relative humidity  20%...90%, without condensation 

Dimensions (LxWxH) 

88 x 57 x 34 [mm] 

Net/gross weight 

0,13kg / 0,16kg 

Protection class PN-EN 60950-1:2007 

II (second) 

Length of detachable AC cable 

1,5m + mains plug 

Storage temperature 

-20ºC...+60ºC 

 

 

 
 
Graph 1.

 

 

Relation between output current and ambient 
temperature. 

Fig.1. Dimension of power supply. 
 

          

 

2. Installation.  

2.1. Requirements. 
The  power  supply  shall  be  mounted  by  the  qualified  installer  having  appropriate  (required  and  necessary  for  a 

given country) permissions and qualifications for connecting (operating) low-voltage installations. The power supply shall 