background image

 

 

PSCLB13830 

PSCLB 13,8V/3A buffer switch mode power supply unit  

 

 

 

 

 

                                                                                                                                                 

 

        PL 

               

                   Edition: 2 from 14.01.2020 

                     Supersedes edition: 1 from 29.03.2018 

                                                                                                                                                          EN

 

 

Features of the power supply unit: 

 

 

DC13,8 V/3 A uninterrupted  0,3 A battery 
charging current 

 

universal AC input voltage range 

90÷264 V  

 

high efficiency 85% 

 

battery charging and maintenance control 

 

deep discharge battery protection (UVP) 

 

battery output protection against short circuit and 
reverse polarity connection 

 

IP 67 case 

 

protections: 

 

SCP short-circuit protection 

 

overvoltage protection  (AC input) 

 

overload (OLP)  

 

warranty 

– 2 year from the production date 

 

1. Technical description. 
 

1.1. 

General description.

 

The buffer power supply is designed for uninterrupted supply of devices requiring stabilized voltage of 

12 V DC (+/-15%)

The PSU supplies voltage of 

13,8 V DC

 with current efficiency of 

I = 3 A + 0,3 A battery charging

. In the case of mains power 

failure,  the  unit  will  instantly  switch  to  battery  power.  The  power  supply  unit  is  protected  against  short-circuit,  overload  and 
overvoltage.  

During  normal  operation,  the  total  current  drawn  by  the  device  cannot  exceed  I=3  A.  The  maximum  battery 

charging current is 0,3 A. The total current of the rec battery is max. 3,3 A.

 

 

           

 

1.2. Specifications. 

Supply voltage 

AC 90÷264 V/50Hz 

Current consumption 

0,4 A@230 V max. 

Supply power 

45 W max. 

Efficiency 

85% 

Output voltage 

11 

V÷ 13,8 V DC – buffer operation  

 9 

V÷ 13,8 V DC – battery operation  

Output current  

3 A + 0,3 A battery charging 

Ripple voltage 

100mV p-p max. 

Battery charging current 

0,3 A max. 

Current consumption by PSU systems 

50mA/13,8 V DC 

Short-circuit protection SCP 

failure melting fuse in the battery circuit (requires fuse replacement) 

Overload protection OLP 

150-200% of power supply, automatic recovery 

Surge protection (AC input) 

varistor 

Deep discharge battery protection UVP 

U<9 V (+/- 0,5 V) 

– disconnection of the battery terminal 

Fuse 

F3,15 A/250 V, mounted using a positive battery cable (BAT+) 

IP protection class 

IP67 

Operation conditions                                            

temperature -10 

o

C÷40

 o

relative humidity  20%...90% without condensation 

Dimensions (LxWxH) 

178 x 56 x 34 [mm] 

Net/gross weight 

0,5kg / 0,6kg 

Protection class PN-EN 60950-1:2007 

II (second) 

Lenght of DC cable 

0,5 m + DC plug 5,5 / 2,1 female 

Lenght of AC cable 

0,4 m 

Storage temperature 

-

20ºC...+60ºC 

 

 

         Fig.1. Dimensions of power supply. 