Pulsar PG15KVTWB Скачать руководство пользователя страница 15

14 

OPERATION

 

AC Applications

 

Before connecting an appliance or power cord to the generator: 

Make sure that it is in good working order. Faulty appliances or Power cords can create a potential for electrical

shock.

If    an    appliance    begins    to    operate    abnormally,    becomes    sluggish,    or    stops    suddenly,    turn     it

off immediately. Disconnect the appliance, and  determine whether  the problem  is the appliance or  the  rated
load capacity of the generator has been exceeded.

Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed

the maximum power rating of the generator. Power levels between rated and maximum may be used for no more
than 30 minutes.

Substantial overloading will open the circuit breaker. Exceeding the time limit for maximum power operation or  slightly

 

overloading the generator may not switch the circuit breaker OFF, but will shorten the service life of the generator.

 

Limit operation requiring maximum power to 30 minutes. 
Maximum power is: 

60Hz   1

5

 kVA

 (GAS)

             1

 

3.5 kVA (LPG); 

For continuous operation (longer than 30 minutes), do not exceed the rated power. 

Rated power is: 
60Hz   1

2

 kVA

(GAS)

1

 

1 kVA (LPG); 

NOTICE

 

High Altitude Operation

At high altitude, the standard carburetor air/fuel mixture will be too rich. Performance will decrease, and fuel 

consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an 

altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions. 

High altitude performance can be improved by specific 

modifications to the carburetor. If you always operate your generator at altitudes above 5,000 feet 

(1,500 meters), have your dealer perform this carburetor modification. This engine, when operated at high altitude with 

the carburetor modifications for high altitude use, will meet each emission standard throughout its useful life. Even with 

carburetor modification, engine horsepower will decrease about 3.5% for each 1,000-foot (300-meter) increase in 

altitude. The effect of altitude on horsepower will be greater than this if no carburetor modification is made. 

Содержание PG15KVTWB

Страница 1: ...Model PG15KVTWB www pulsar products com Generator OPERATOR S MANUAL...

Страница 2: ...isfaction and will be pleased to answer your questions and concerns A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important And using this generator safely is an important res...

Страница 3: ...System 9 Ground Terminal 9 Fuel Gauge 9 VoltMeter 9 Hour Meter 9 BEFORE OPERATION 10 ARE YOU READY TOGET STARTED 10 Knowledge 10 IS YOUR GENERATORREADY TOGO 10 Check the Engine 10 Check the Battery 1...

Страница 4: ...NG 22 SPARKPLUG SERVICE 23 BATTERY SERVICE 24 BatteryRemoval 24 BatteryCharging 25 STORAGE 26 STORAGE RECAUTION 26 Cleaning 26 Fuel 26 STORAGE PROCEDURE 27 STORAGE PRECAUTIONS 28 REMOVALFROMSTORAGE 28...

Страница 5: ...e in wet conditions such as rain or snow or near apool or sprinkler system or when your hands are wet could result in electrocution Keep the generator dry If the generator is stored outdoors unprotect...

Страница 6: ...partially enclosed area the air you breathe could contain a dangerous amount of exhaust gas Never run your generator inside a garage house or near open windows or doors Do not connect to a building s...

Страница 7: ...Use the illustrations on these pages to locate and identify the most frequently used controls CONTROL PANEL LPG PORT THE FIRST STAGE REGULATOR THE SECOND STAGE REGULATOR HOUR METER CIRCUIT BREAKER ENG...

Страница 8: ...7 CONTROLS FEATURES CYLINDER CRANIUM AIR CLEANER OIL TANK CAP EMPTY FULL OIL GAUGE OIL LEVEL DIPSTICK BATTERY OIL DRAIN TUBE STARTER MOTOR...

Страница 9: ...ing and for restarting a warm engine EngineSwitch The engine switch controls the ignition system and it operates the electric starter FUEL VALVE LEVER CHOKE KNOB STOP Stops the engine The engine switc...

Страница 10: ...es that apply to the intended use of the generator Attention It is compulsorily to make protective earthing before operating the generator Protective earthing must correspond to Rules for Installing E...

Страница 11: ...ake care of any problem you find or have your servicing To prevent a possible fire keep the generator at least 1 meter away from building walls and other equipment during operation Do not place flamma...

Страница 12: ...Faulty appliances or power cords can create a potential for electric shock Make sure the electrical rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power...

Страница 13: ...release the key and wait at least 10 seconds before operating the starter again Using the electric starter for more than 5 seconds at a time will Overheat the starter motor and can damage it 5 If the...

Страница 14: ...sconnect the appliance and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded Substantial over loading may damage the generator Marginal ov...

Страница 15: ...to 30 minutes Maximum poweris 60Hz 15 kVA GAS 13 5 kVA LPG For continuous operation longer than 30 minutes do not exceed the rated power Rated poweris 60Hz 12 kVA GAS 11 kVA LPG NOTICE High Altitude O...

Страница 16: ...trician and must comply with all applicable laws and electrical codes In some areas generators are required by law to be registered with local utility companies Check local regulations for properregis...

Страница 17: ...emperature operation or use it in dusty conditions consult your servicing dealer for recommendations applicable to your individual needs anduse Remember that your servicing dealer knows your generator...

Страница 18: ...NCESCHEDULE NOTE Replace the paper element only 1 Service more frequently when used industry areas 2 These items should be serviced by your servicing dealer unless you have the proper tools and are me...

Страница 19: ...fuel is not covered underwarranty NOTE Gasoline spoils very quickly depending on factors such as light exposure temperature and time In worst cases gasoline can be contaminated within 30days Using co...

Страница 20: ...fuel from an unfamiliar station try to find out If the fuel contains alcohol if it does confirm the type and percentage of alcoholused If you notice any undesirable operating symptoms while using a g...

Страница 21: ...ible with the environment We suggest you take it in a sealed container to your local service station or recycling center for reclamation Do not throw it in the trash pour it on the ground or pour it d...

Страница 22: ...vice category are on the API label on the oil container AIR CLEANERSERVICE 1 Release four latch tabs from the air cleaner cover and remove the cover 2 Foam airfilter a Remove the foam air filter from...

Страница 23: ...nance Schedule 1 Clean the foam air filter in warm soapy water rinse and allow to dry thoroughly or clean in non flammable solvent and allow todry 2 Dip the foam air filter in clean engine oil then sq...

Страница 24: ...plug wrench commercially available 3 Inspect the spark plugs Replace them if the electrodes are worn or if the insulator is cracked chipped or fouled 4 Measure the spark plug electrode gap with a wir...

Страница 25: ...p or other container for at least fifteen minutes Water under pressure can damage the eye Immediately call aphysician Skin Remove contaminated clothing Flush the skin with large quantities of water Ca...

Страница 26: ...f the battery s ampere hour rating 1 Connect the battery charger following the manufacturer sinstructions 2 Chargethebattery 3 Clean the outside of the battery and the battery compartment with a solut...

Страница 27: ...l tank with fresh gasoline If only partially filled air in the tank will promote fuel deterioration during storage If you keep a container of gasoline for refueling be sure that it contains only fresh...

Страница 28: ...engine and place it in a suitable container c Loosen the carburetor drain screw d Drain the gasoline from the carburetor into the container e Tighten the carburetor drain screw securely 2 Change the...

Страница 29: ...valve lever in the OFF position to reduce the possibility of leakage Place the generator on a level surface Tilting can cause fuel or oil leakage With the engine and exhaust system cool cover the gene...

Страница 30: ...tem can burn you and can ignite some materials Keep the generator level when transporting to reduce the possibility of fuel leakage Move the fuel valve lever to the OFF position When using ropes or ti...

Страница 31: ...Gap or replace spark plug p 23 Spark plug wet with fuel floodedengine Dry and reinstall sparkplug 5 Take generatorto an authorized THIS servicing dealer or refer to shop manual Fuel filter restricted...

Страница 32: ...on afterstarting Switch circuit breaker ON 2 Check the powertool or appliance at a known good AC powersource Faulty power tool orappliance Replace or repair power tool or appliance Stop and restart th...

Страница 33: ...difications to the carburetor If you always operate your generator at altitudes above 1 500 meters have your authorized THIS servicing dealer perform this carburetor modification Even with carburetor...

Страница 34: ...ximatly 1 6L Fuel TankCapacity 40L Spark Plug F7TC NHSPLD Battery 12V 21AH Generator Model Single phase AC output Rated voltage 120V 240V Rated frequency Rated Ampere 100A 50A Rated output 12kW GAS 11...

Страница 35: ...34 TECHNICAL INFORMATION WIRING DIAGRAM...

Страница 36: ...components parts and labor Year 2 Limited coverage on generator engine components parts only Personal use means personal residential household use or recreational use by the retail consumer Commercia...

Страница 37: ...e United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under thi...