background image

 

 

 

MPSB12 

                                                                v.1.0

 

PSB 13,8V automation module 

 

               

 Edition: I (08 Mar2012)  

EN

*

 

 

Features: 

 

 

battery status control 

 

works with PSB 13,8V power supply units 

 

LED indication 

 

FAC technical output indicating AC power 
collapse – OC and relay type 
 

  FPS technical output indicating power supply 

module’s failure 

  FLB technical output indicating low battery 

voltage 
 

 
1. Technical description. 
 

1.1 General description 

MPSB12 automation module is intended for indicating the operating status of buffer power supplies PSB 13,8V type. 
The PCB board features LEDs that indicate PSU operating status (presence of AC voltage, presence of DC voltage, 
battery voltage). The module is also equipped with technical outputs of: AC power loss, PSU failure, low battery 
voltage. 

1.1. Description of the module’s components and connectors (fig1, tab.1) 

Table 1 

Element 

no. 

Description 

[1] 

LED indicating presence of 230VAC voltage 

[2] 

LED indicating presence of DC voltage at the PSU output 

[3] 

LED indicating correct battery voltage 

[4] 

FAC- technical output indicating AC absence – relay type 

[5] 

FAC- technical output indicating AC absence – OC  type 

[6] 

FPS- output indicating DC absence/PSU failure - OC  type 

[7] 

FLB- output indicating low battery voltage - OC  type 

[8] 

Indication connector 

[9] 

+BAT- battery connector 

[10] 

+V –13,8V supply 

 

 

 

 
 
                                                               

Fig. 1. The view of the module. 

 
 
 

Содержание MPSB12

Страница 1: ...te PSU operating status presence of AC voltage presence of DC voltage battery voltage The module is also equipped with technical outputs of AC power loss PSU failure low battery voltage 1 1 Description of the module s components and connectors fig1 tab 1 Table 1 Element no Description 1 LED indicating presence of 230VAC voltage 2 LED indicating presence of DC voltage at the PSU output 3 LED indica...

Страница 2: ...y 20 90 without condensation Storage temperature 20ºC 60ºC Table 3 Dimensions 110 x 44 x 55 LxWxH mm 2 Fixing M3 screws mounting plate adjusted for PSB13 8V series power supplies Connectors Ф0 41 1 63 AWG 26 14 Net gross weight 0 1 0 13 kg 2 1 Requirements The module is to be mounted by a qualified installer holding relevant permits and licenses applicable and required for a given country for 230V...

Страница 3: ...BLE It can cause a device failure or an electric shock 7 Connect load loads to proper output connectors of the power supply positive pole is marked as V negative pole as V 8 Connect the battery in accordance with the signs colours 9 Once the tests and operation control have been completed the enclosure cabinet can be locked Fig 2 Diagram of connecting the module to the PSB power supply unit Fig 3 ...

Страница 4: ...ccepted the manufacturer is obliged to provide warranty repairs at the earliest convenience however not later that within 14 days from the delivery to the service centre of the manufacturer 7 The repair period mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms b...