Page 23
Hazardous Area Installation
Not all MicroFlow models are ATEX certified, check label for approval details.
The ‘X’ in the certifications number indicates that certain special conditions apply.
This version must be supplied from apparatus that provides protection from
prospective short circuits up to 1500A. The fuse is fitted in the safe area end of
the cable.
Important Information
Below is an example of the wrap around label that is found on an ATEX
approved MicroFlow. If this information does not appear on the label of
your MicroFlow sensor it is not ATEX approved for hazardous area.
Ex mb Version
PSU
V
24VDC
+
-
PC
HAZARDOUS
AREA
SAFE AREA
Ex mb Version RS485
RS485
FlowCERT, Velocity Interface,
Ultimate, PC or Modbus master
100Ma FUSE BREAKING
CAPACITY 1500a PRE-FITTED
IN CABLE
Um=28V
PROSPECTIVE
SHORT CIRCUIT
CURRENT 1500A