PULSAR MEASUREMENT
53
When a signal is received, the Green square indicator will move down from
90 on the vertical axis. The further the Green indicator moves from 90, the
larger the strength of the received signal. During flow condition, the Green
indicator will normally be within the range of 30 to 70.
When flow is detected, the Red circle indicator will move horizontally to
indicate flow detection. The Red indicator should always be within 80 to 90
on the vertical axis, under both flow and no-flow conditions. On the
horizontal axis, the Red indicator should stay at 0 under no-flow and move
along the horizontal axis when flow is detected.
Under flow condition, the line should still approach and flat-line at signal
index 90.
If the trace remains flat or the indicators struggle to remain stable during
flow, then increase the Sensitivity setting.
Refer to the High Noise Environment section if unusual observations are
seen on the diagnostic trace.
PC-over-RS485
In addition to the RS232 port, FlowPulse can also be interfaced to the PC via
the RS-485 connection. A standard USB to RS485 converter is required.
While using PC over RS-485, the Modbus RTU protocol will not be available.
Follow these steps to use PC over RS-485:
•
If PC-over-485 is already enabled, then skip to Step 3otherwise
connect over RS232 and use FlowPulse PC to set the RS485 mode to
PC-485. Alternatively, if Modbus RTU is running on RS485, set
register 51 to a value of 3.
•
Once the mode is saved or the register set, the change will take
effect immediately. Therefore, current connection of FlowPulse PC
over RS232 or Modbus will be terminated.
•
Remove the USB to RS232 converter, and connect the USB to RS485
converter to FlowPulse.
To restore, set RS485 mode to Off or Modbus RTU (register 51 to 0 or 1). Set
the baud rate on FlowPulse PC back to 57600 when using the RS232 port.