www.pulsar.pl
DSOP24V
19
5.4.6. The current failures „FLc”
In the event of abnormal electrical parameters during operation, the power supply will indicate a failure by
illuminating the corresponding LED on the panel and activating the acoustic indication (if not disabled).
The power supply unit can simultaneously signal several failures at the same time. In such a case, all failure
codes and their priority can be viewed in the
FLc
menu. While in the menu, each time you press the "OK" button on
the panel, the next error code that caused the failure is displayed. If several failures occur simultaneously, pressing
the "OK" button again will display the next code. The order of failure display is arranged according to priority. The
failures that are displayed first are of the highest priority.
The section 5.4.7 summarizes all failure codes that may appear during the power supply operation. The
individual codes are accompanied by appropriate optical signaling on the panel, acoustic signaling and the
activation of a dedicated technical output.
-
Use the „<” or „>” buttons in order to display the "FLc" parameter
-
Press „OK”
- The number 1, indicating the failure number (highest priority) in the memory,
will be displayed
Then, after 1s., the error code will be automatically displayed
-
Press „OK”
- The number 2, indicating the failure number in the memory, will be displayed
Then, after 1s., the next error code will be automatically displayed
- If there are more failures in the memory, press the "OK" button to display the next codes
- The "- -" parameter on the display indicates the end of the failure list