The 

ChromaBank IP

 contains state of the art, high brightness, high 

efficiency Red, Green and Blue LEDs.  These three primary colours 
can be mixed together to make an incredible palette of 16.7 million 
colours. 
They are IP65 rated fixtures and therefore suitable for outdoor or 
indoor use. They are powered directly from 100-240 Volts AC and 
have full remote DMX control of RGB levels or can function in Stand 
Alone Mode.  Numerous chases and sequences are built in, enabling 
superb lighting effects without complicated programming. 

These impressive fixtures are ideal for the architectural and 
entertainment markets to give an unlimited colour palette that can 
enhance building facades, water features and focal displays or to 
providing stunning dynamic colour in shows, conferences, concerts 
and themed environments. 

Like the 

ChromaBank,

 the 

ChromaBank IP

 contains a 

PULSAR 

ChromaZone

 controller and can therefore also operate in 3, 6, 9, 10, 

36, 42 or 46 Channel Modes. 
The 

ChromaBank IP 100

 may be configured as 

Fixture 1 of 2

 or 

Fixture 2 of 2

, displaying the LED segments 1-6 of 12 or 7-12 of 12.  

So, two 

ChromaBank IP 100

s may emulate a 

ChromaBank IP 200

Please see the 

Channel Assignments Tables 

sheet for details of 

the different modes. 

The 

ChromaBank IP

 has numerous chases and effects built in, 

making it possible to achieve fantastic effects without programming.  
These internal effects can be selected via the 

User Interface 

Module

 (UIM) on the rear of the units whilst in Stand Alone mode, or 

from a controller using a digital 

PMX

  (

P

ulsar 

M

ultiple

X

) or 

DMX

 

(

D

igital 

M

ultiple

X

) signal. 

Please see the 

Menu Selection Overview

 sheet for a pictorial 

representation of the menu functions. 

The 

ChromaBank IP

 has a stand and mounting brackets making it 

ideal for floor, wall, ceiling or rig mounting. 

The 

ChromaBank IP

 has a colour code letter. This signifies the 

finished colour of the fixture e.g. B = Black, S = Silver. 

The 

ChromaBank IP

 has a thermal management system. This 

progressively reduces the power to the LEDs if the internal 
temperature exceeds limits set by the software. 
Excess temperature will occur if the units are exposed to high 
ambient temperatures or inadvertently covered. It is therefore 
important for maximum performance that they have good ventilation 
on all sides. 

NB - Patents applied for 

Mains Supply

 - The 

ChromaBank IP

 works correctly on any mains 

voltage from 100-240 VAC, 50-60Hz, (self adjusting).  Power 
consumption is 100, 200 or 300 Watts max. 
A 5m, bare ended, mains cable is provided.  The bare end of the 
cable should be fitted with a suitably approved and rated mains plug.   
Note: in some countries it is a requirement that such a plug be fitted 
by a qualified electrician. 

CABLE COLOURS

 

Green/Yellow =  

Earth / Ground 

Brown = Live / Phase / Hot 

Blue = Neutral 

WARNING - THIS APPLIANCE MUST BE EARTHED 

For safety we recommend the use of a Residual Current Circuit 
Breaker.  An RCCB MUST be used when powering a 
ChromaBank IP in wet environments. 

PMX/DMX In/Thru 5 Pin XLR Connectors

 

Digital Control Signals:

 Two 5 pin XLR connectors on 5m cables 

(in/thru) are provided.  The pin connections of the sockets are: 

PMX (RS232/423) SIGNAL 

DMX SIGNAL 

Pin 1 = Screen / Chassis Earth 

Pin 1 = Screen / Chassis Earth 

Pin 2 = Signal 

Pin 2 = Signal 

-

 

Pin 3 = Signal Earth 

Pin 3 = Signal 

+

 

Pin 4 = no connection 

Pin 4 = no connection 

Pin 5 = LVS (male only) 

Pin 5 = LVS (male only) 

Wet / Damp Environment Use

 – these products are IP65 

rated.  However, the cable connections 

must

 also be 

contained in a dry, low humidity, environment as water and 

vapour will travel inside the cables from the connection joints into the 
fixture.  A waterproof connection box, or properly fitted IP68 rated 
connectors, are essential for cable connections in such 
environments.  Suitable connectors are available from Pulsar. 

Failure to take these precautions invalidates the guarantee.

 

CONNECTIONS 

SPECIFICATION 

CHROMABANK IP 100 

CHROMABANK IP 200 

Содержание CBankIP100

Страница 1: ...ing or rig mounting The ChromaBank IP has a colour code letter This signifies the finished colour of the fixture e g B Black S Silver The ChromaBank IP has a thermal management system This progressively reduces the power to the LEDs if the internal temperature exceeds limits set by the software Excess temperature will occur if the units are exposed to high ambient temperatures or inadvertently cov...

Страница 2: ...6 or 12 way using the or keys When the required chase pattern way number shows in the display press the Yes key to save changes or X Back key to restore the previous settings Channel 10 may be set as a Grand Master for the 36 RGB channels only OR as a Global Grand Master for the 36 RGB channels the ALL Red Green and Blue and the Chase Levels To set the required Ch 10 mode of operation press the or...

Страница 3: ...0 300 Chase patterns 12 CBankIP100 12 CBankIP200 300 Channel 10 Grand Master for the 36 RGBs only Input Smoothing ON Low Voltage Supply ON DMX Line Termination OFF If NoSignal use Stand Alone Mode Stand Alone Settings Ch 1 3 0 bits 0 Ch 4 Chase 1 Select Auto Chase Ch 5 Chase 1 Speed 128 bits 50 Ch 6 Chase 1 Level 255 bits 100 Ch 7 46 0 bits 0 Failure of the internal ChromaBank IP 5 Amp 5x20mm Powe...

Страница 4: ......

Страница 5: ...e Fixture 1 of 2 Fixture 2 of 2 1 6 as 6 Channel Mode 1 6 as 6 Channel Mode 1 6 as 6 Channel Mode 7 Red 1 25 Red 1 7 Fixture 1 Red 1 8 Green 1 26 Green 1 8 Fixture 1 Green 1 9 Blue 1 27 Blue 1 9 Fixture 1 Blue 1 22 Red 6 40 Red 6 40 Fixture 1 Red 12 23 Green 6 41 Green 6 41 Fixture 1 Green 12 24 Blue 6 42 Blue 6 42 Fixture 1 Blue 12 46 Channel Mode ChromaBank IP 100 18 Channels Fixture ChromaBank ...

Страница 6: ...rd Use Channel1 14 89 228 Rainbow Strobe 13 86 220 White Any Colour Strobe Channels 1 2 3 set colour 83 212 White Any Colour Crossover Channels 1 2 3 set colour 12 80 204 Blue Yellow Wave Reverse 77 196 Blue Yellow Wave Forward 73 188 Green Magenta Wave Reverse 11 70 180 Green Magenta Wave Forward 67 172 Red Cyan AnyCol Op Col Wave Forward Channels 1 2 3 set colour All 3 at 0 Red Cyan 10 64 164 Re...

Страница 7: ...No Sig Chan Levels DMX Address n Receiving t X Change X Restore If NoSignal use t Stand Alone Sett ings View Change ChromaZone Mode nn Channels 3 6 9 10 36 42 46 18 CBankIP100 36 CBankIP200 1or2 of 2 CBankIP100 1 of 1 CBankIP200 6 Way 12 Way CH10 36xRGB GM CH10 Global GM ON Gentle Smooth OFF Fast Video ON OFF ON OFF Stand Alone Mode Last DMX Packet Channel Assignments Tables and Chase Select Table...

Страница 8: ......

Страница 9: ...suitably qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped DO NOT block any of the ventilation openings Install the apparatus as specified in the In...

Страница 10: ......

Отзывы: