![Pulsar Measurement IMP Lite Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/pulsar-measurement/imp-lite/imp-lite_instruction-manual_1625416007.webp)
PULSAR MEASUREMENT
7
About the IMP Lite
Functional Description
The IMP Lite level monitoring system is a highly developed ultrasonic level
measurement system which provides non-contacting level measurement for
a wide variety of applications in both liquids and solids.
Easy calibration and maintenance free “fit and forget” means that you can
install the IMP Lite Level Monitoring System rapidly and with confidence.
The IMP Lite operates on the principle of timing the echo received from a
measured pulse of sound transmitted in air and utilises “state of the art”
echo extraction technology. The IMP Lite comes in three models:
•
Lite 3
with a range from 0.20m (0.66 feet) to 3.00m (9.84 feet).
•
Lite 6
with a range of 0.3m (0.98 feet) to 6.00m (19.69 feet).
•
Lite 10
with a range of 0.3m (0.98 feet) to 10.00m (32.81 feet).
The IMP Lite can show
level
,
space, distance
, on the display. There is an
isolated 4-20 mA output that can be connected to a remote chart recorder
or PLC, to monitor level, space or distance, dependant on the measurement
mode selected, and provides a ‘fault condition’ alarm of either 3.5mA or
22mA.
The IMP Lite lid has an integral LCD display and 4 buttons which are used for
programming purposes when in Program Mode and as hot keys providing
additional information whilst in Run Mode.
Содержание IMP Lite
Страница 1: ...IMP Lite Instruction Manual...
Страница 2: ...2...
Страница 9: ...PULSAR MEASUREMENT 9 EU Declaration of Conformity...