![Pulsar Measurement FlowCERT Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/pulsar-measurement/flowcert/flowcert_instruction-manual_1625413060.webp)
FLOWCERT LITE (UL) INSTRUCTION MANUAL
60
Ratiometric
If the flow calculation is to be
ratiometric P702 = 2
the flow will be
calculated using the formula: q= q
cal
C
e
/C
ecal
(h
e
/h
ecal
)
1.5
Where:
q = flowrate
q
cal
=
flowrate at maximum head P705
Ce
=
discharge coefficient
calculated by FlowCERT (P723)
Ce
cal
= discharge coefficient at maximum head
he = effective head
he
cal
= effective head at maximum head
BS3680 V-Notch Weir
Absolute
If the flow calculation is to be
absolute
P702
=
1
the flow will be calculated
using the formula: q = C
e
8/15tan(theta/2)(2gn)
0.5
h
2.5
Where:
q = flowrate
Ce
=
discharge coefficient
calculated by FlowCERT Lite (P723
)
theta = V-notch angle
gn = gravitational acceleration (nominal value = 980.66 cm/s
2
)
h = head
The FlowCERT Lite pre-sets the angle (theta) on selection of the chosen
device this angle is
90°
for a BS 3680
full 90°V notch
weir,
53° 8 minutes
in
the case of the BS3680
half 90°V notch
weir and
28° 4 minutes
in the case
of the BS3680
quarter 90°V notch
.
Ratiometric
If the flow calculation is to be
ratiometric P702 = 2
the flow will be
calculated using the formula: q = q
cal
C
e
(h)/C
e
(h
cal
)(h/h
cal
)
2.5
Where:
q = flowrate
q
cal
=
flowrate at maximum head P705
Ce(h) = discharge coefficient for head
Ce(h
cal
)
=
discharge coefficient for maximum head
h = head
h
cal
=
maximum head P704
Содержание FlowCERT
Страница 1: ...FlowCERT Lite UL Instruction Manual...
Страница 2: ...2...
Страница 14: ...FLOWCERT LITE UL INSTRUCTION MANUAL 14 EU Certificate of Conformity...
Страница 142: ...FLOWCERT LITE UL INSTRUCTION MANUAL 142 NOTES...