FLOWCERT LITE (UL) INSTRUCTION MANUAL
56
U-Throated Flume
Absolute
If the flow calculation is to be
absolute
P702
=
1
the flow will be calculated
using the formula: q = (2/3)
1.5
g
n
0.5
C
u
C
v
C
d
bh
1.5
Where:
q = flowrate
g
n
= gravitational acceleration (nominal value = 980.66 cm/s
2
)
h = head
C
u
=
shape coefficient
calculated by FlowCERT Lite (P724)
C
v
=
velocity coefficient
calculated by FlowCERT Lite (P721)
C
d
=
discharge coefficient
calculated by FlowCERT Lite (P722)
b
=
throat width P711
Ratiometric
If the flow calculation is to be
ratiometric P702 = 2
the flow will be
calculated using the formula:
q= q
cal
(C
v
/C
vcal
)(C
d
/C
dcal
)(C
u
/C
ucal
)(h/h
cal
)
1.5
Where:
q = flowrate
q
cal
=
flowrate at maximum head P705
Cv
=
velocity coefficient
calculated by FlowCERT Lite (P721)
Cv
cal
= velocity coefficient at maximum head
Cd
=
discharge coefficient
calculated by FlowCERT Lite (P722)
Cd
cal
=
discharge coefficient at maximum head
Cu
=
shape coefficient P724
Cu
cal
= shape coefficient at maximum head
h = head
h
cal
=
maximum head P704