FPS300.246-036-104
FPS300.246-049-102
All parameters are specified at 24 V, 12.5 A, 230 Vac, 25 °C ambient and after a 5 minutes run-in time unless otherwise noted.
Apr. 2022 / Rev. 0.2 FPS300-EN
16 / 43
Efficiency and Power Losses
AC 100V
AC 120V AC 230V
Efficiency
typ.
93.6%
94.3%
95.7%
At 24V, 300W
Average
efficiency
*)
typ.
92.9%
93.5%
94.6%
25% at 80W, 25% at 150W, 25% at 220W, 25% at
300W
Power losses
typ.
2.7W
2.8W
2.2W
At 24V, 0W (no load)
typ.
10.7W
10.0W
8.3W
At 24V, 150W (half load)
typ.
20.5W
18.1W
13.5W
At 24V, 300W (full load)
*)
The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of
the nominal load for 25% of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal
load for another 25% of the time and with 100% of the nominal load for the rest of the time.
Fig. 9-1: Efficiency vs. output power at 24 V, typ.
Fig. 9-2: Losses vs. output power at 24 V, typ.
Fig. 9-3:
Efficiency vs. input voltage at 24 V, 300 W, typ.
Fig. 9-4:
Losses vs. input voltage at 24 V, 300 W, typ.
A
B
C
A
230Vac
C
100Vac
B
120Vac
Efficiency (%)
96
95
94
93
92
91
90
360
200
300
100
0
Output Power (W)
A
B
C
A
100Vac
C
230Vac
B
120Vac
Power Losses (W)
25
20
15
10
5
Output Power (W)
360
260
60
160
-40
Efficiency (%)
Input Voltage (Vac)
92,0
94,0
96,0
50
300
100
150
200
250
Power Losses (W)
Input Voltage (Vac)
10,0
20,0
15,0
25,0
50
300
100
150
200
250