CS20.241, CS20.241-A1
C-Series
24V,
20A,
S
INGLE
P
HASE
I
NPUT
Preliminary
9.
E
FFICIENCY AND
P
OWER
L
OSSES
AC 100V
AC 120V
AC 230V
Efficiency
typ.
92.0%
92.7%
94.0%
at 24V, 20A
typ.
91.6%
92.4%
94.0%
at 24V, 24A (Power Boost)
Average efficiency *)
typ.
91.3%
92.0%
93.3%
25% at 5A, 25% at 10A,
25% at 15A. 25% at 20A
Power losses
typ.
6.8W
3.2W
3.2W
at 24V, 0A
typ.
21.1W
20.1W
17.0W
at 24V, 10A
typ.
41.7W
37.8W
30.6W
at 24V, 20A
typ.
52.8W
47.4W
36.8W
at 24V, 24A (Power Boost)
*) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25%
of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100%
of the nominal load for the rest of the time.
Fig. 9-1
Efficiency vs. output current at 24V,
typ
Fig. 9-2
Losses vs. output current at 24V, typ.
Efficiency
4
6
8 10 12 14
18 20
24A
86
87
88
89
90
91
92
93
94%
100Vac
120Vac
230Vac
Output Current
16
22
Power Losses
0 2
6 8
12 14
24A
10
0
20
30
40
60W
18 20
50
4
10
16
Output Current
22
120Vac
100Vac
230Vac
Fig. 9-3
Efficiency vs. input voltage at 24V,
20A, typ.
Fig. 9-4
Losses vs. input voltage at 24V, 20A,
typ.
Efficiency
120
180
230
264Vac
89
90
91
92
Input Voltage
93
94
95%
100
Power Losses
120
180
230
264Vac
20
25
30
35
Input Voltage
40
45
50W
100
Jan. 2012 / Rev. 0.5 DS-CS20.241-EN
Preliminary
All parameters are specified at 24V, 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
9/25