PULOON Technology Inc.
LCDM-1000
27
- Is DIV SENSOR 1 / 2 normal?
- Is GAP between SHAFT DIVERTER ASS’Y and SHAFT
ASS’Y CASH FEED proper?
- Is idle roller rotation in GUIDE CASH FEED 5 ASS’Y normal?
Check
Point
- JAM at DIV Sensor
- Purge error(JAM at DIV Sensor)
Meaning
- Try again after checking above situation.
- In case of interference between SHAFT DIVERTER ASS’Y
&
SHAFT ASS’Y CASH FEED 3, Adjust location of SOLENOID
PIN( Please refer to below picture)
- Replace ASS’Y in case of idle roller rotation problem in
GUIDE
CASH FEED 7 ASS’Y.
Action
36H, 4EH
CODE
Solenoid and
Solenoid pin should
be adjusted in
arrow direction
TABLE 4