background image

WARNING:

All persons engaged in, or in the immediate vicinity of asbestos
removal operations are required to observe all applicable sections of
O.S.H.A. regulation 1910.1001, as amended in the Federal Register.
Also observe all applicable local, state, federal E.P.A. regulations and
other regulations involving the removal of hazardous materials.

Use extreme caution when removing vacuum equipment from the
work site for transportation and/or storage. Surfaces of the pick-up
tools, wand, hose and canister may remain contaminated with fine
asbestos particles. It is RECOMMENDED that used equipment be
enclosed in sealed poly bag prior to removal from the work site.

Handle the can cap and filter assembly with care to avoid damage to
the vacuum sealing surfaces. Damage such as bending, denting, or
cracking will result in leaks and loss of system efficiency. such dam-
age is not covered by your warranty.

TO OPERATE:

The vacuum cleaner is designed to perform as a dry unit only.

With the HEPA Filter Assembly in place, the can cap securely clamped
and the crushproof hose with dusting brush tool attached, plug the
power cable into the proper outlet. The vacuum cleaner is ready for
use.

HEPA FILTER SYSTEM:

Component Description:

• The air seal gasket between the canister and the can cap forms a

positive air lock.

• The paper filter bag provides primary filtration.

• The cloth filter provides secondary filtration.

• The HEPA filter provides final filtration.

Save For Future Reference

CAUTION

This vacuum unit is for 

DRY PICK-UP ONLY.

Liquid pick-up may

damage the unit and will invalidate your warranty.

#30 ASB Bacpac Asbestos Vacuum

Operation & Care Instructions

This vacuum is a high performance asbestos clean-up system, designed to efficiently remove asbestos
debris and dust from contaminated areas. All parts used in the manufacturing of this vacuum have passed
rigid quality control standards prior to assembly, and an "each unit" final inspection prior to packaging is
your assurance of proper assembly. This vacuum was protectively packed to prevent possible damage in
transit. Should damage occur, please notify the transporting carrier immediately for loss and/or claim.

IMPORTANT SAFEGUARDS & OPERATIONS

INSTALLATION:

A. HEPA Filter - 

Carefully place the HEPA Filter into the vacuum can-

ister. Center the HEPA Filter so the rim of the canister is in con-
tact with the HEPA Filter’s gasket.

B. Cloth Bag - 

Place the cloth filter within the core of the HEPA fil-

ter. Seat the cloth filter’s gasket against the flange of the HEPA
filter.

C. Paper Bag - 

Attach the paper bag to the vacuum inlet on the

internal side of the can cap and fold the bottom of the bag length-
wise so it fits easily inside the cloth filter.

FILTER CARE & MAINTENANCE:

(Periodically inspect all filters)

A. The primary filter (paper bag) is not reusable. When the bag is

filled to the point where vacuum efficiency is reduced, it must be
replaced with a new one. Remove the paper bag, place in a spe-
cially marked plastic bag and dispose of properly. Install a new
primary filter (paper bag) as stated in “Filter Installation”. Do not
operate vacuum cleaner without the primary filter (paper bag) in
place.

B. The cloth secondary filter is placed within the core of the HEPA fil-

ter. The gasket sewn onto the cloth filter should seat against the
flange of the HEPA filter.

C. The final or H.E.P.A. filter is a sealed unit and cannot be cleaned.

Periodically make a visual inspection of this filter for excessive
amounts of debris. If the filter media appears to be clogged, has
a hole, or has changed color (should be white), indicating exces-
sive dirt build-up, replace with a new filter, making sure to install
secondary and primary filters. Place the used filters in the spe-
cially marked plastic bag, seal and dispose of properly.