User’s Manual 

 

 
 
PTS-G5K13M 

RF Generator 5kW / 13MHz 

 
 
 
 
 
 
 
 
 

 

PTS co.,Ltd. 

68-1, Sangdeok-ro, Idong-myeon, 
Cheoin-gu, Yongin-si, Gyeonggi-do, 
#17126, Korea 
Tel. 031-321-5670 
Fax. 031-332-5670 

Содержание PTS-G5K13M

Страница 1: ...User s Manual PTS G5K13M RF Generator 5kW 13MHz PTS co Ltd 68 1 Sangdeok ro Idong myeon Cheoin gu Yongin si Gyeonggi do 17126 Korea Tel 031 321 5670 Fax 031 332 5670...

Страница 2: ...ents 1 Safety Precautions 2 System Standard 3 Dimensions 4 RF Generator System Overview 5 Installation 6 A D Interface 7 RS232C Communication 8 Handy Controller Remote Operations 9 Interlock and Alarm...

Страница 3: ...ated on the diagrams contained in this manual Ground the Equipment To prevent electrical shock by the AC power source please make sure that the equipment is securely connected to ground If the product...

Страница 4: ...we are not responsible under any circumstances This equipment should not be inspected by one person only Make sure that the person who operates the RF Generator is always around Do not change parts or...

Страница 5: ...ult in serious injury or worse It warns that there is a potential risk A symbol shows a care that should be taken to avoid danger or mistakes It tells you potential activities to reduce serious damage...

Страница 6: ...PTS G5K13M PTS Co Ltd 6 This symbol is asked to refer to the Manual for reliable equipment operation This symbol indicates the position where one has to connect Ground for reliable equipment operation...

Страница 7: ...trol by CPU Cooling Method Water Cooling Forced Air Water 7 min 0 5Mpa 10 35 PH7 8 Air 1 5 min Remote Terminal Analog Control D Sub 25Pin RS 232C Control Option Ambient Temperature range 5 40 Output M...

Страница 8: ...Via RS 232C terminal Device Net Selectable on the rear of Generator Power Control can be controlled 2 4 Installation site Please maintain the ambient temperature to 5 40 when the generator is in oper...

Страница 9: ...PTS G5K13M PTS Co Ltd 9 3 Dimensions...

Страница 10: ...play LED POWER It displays the main power input status It lights when power is turned on INT L External interlock light turns on when normal RF ON LED Light turns on when RF On is on ALARM Light turns...

Страница 11: ...g input RC 3 8 Water Cooling output RC 3 8 Input and Output Pulse input connector RF control pulse at the output by an external pulse signal BNC R Pulse output connector Analog Interface D SUB connect...

Страница 12: ...the circuit breaker is OFF connect the coaxial cable to the output terminal of the Generator Make sure the cooling water is inflow before you switch on the RF power output 5 1 Cable Connection Power C...

Страница 13: ...hing Unit and Generator Output is are connected using coaxial cable Control Connection Analog Interface Analog Voltage Control Connect a Control Signal to the Analog Interface Terminal D Sub 25pin Con...

Страница 14: ...F On Status output Analog RF on Status Max 30V 100mA 4 ALARM Output Analog ALARM Max 30V 100mA 5 INT EXT STAT Output Analog INT EXT Status Max 30V 100mA 6 NC 7 RF Set Input Analog RF Set Voltage 0 10V...

Страница 15: ...itor Return 24 NC 25 NC Please use D GND and remove A GND Analog Interface Connector Pin Functions RF On Off RF power On Off Signal Pin 1 14 Open while RF off and Close while RF On INT L Interlock Sig...

Страница 16: ...Ltd 16 Pin 7 Set RF to a 0 10V RF Output Power Set 0 3 000W to 20 A GND Pf Moni FWD Power Monitor 7 RS232C Communication 7 1 Communication Specification Baudrate 57 600bps Data width 8bits Parity Even...

Страница 17: ...TS Co Ltd 17 7 2 Communication Protocol Length SM LEN ID CMD DATA CRC EM CRC Name Size Function SM 1 Start Marker 0x05 LEN 1 Length ID 1 ID CMD 1 Command DATAn n DATA field CRC 1 CRC XOR calc EM 1 End...

Страница 18: ...04 80 04 XX 0A 12 get slow up time 05 02 80 44 XX 0A 13 respond slow up time 05 04 80 C4 XX 0A 14 get arc cut count 05 02 80 45 XX 0A 15 respond arc cut count 05 04 80 C5 XX 0A 16 get pwr 05 02 80 46...

Страница 19: ...0 000 0x0000 0x2710 15 14 null not assignment read data is 0 id null cprr 0x80 13 0 pr power monitor NOTE current pf power unit is W cmd 0xC3 0 10 000 0x0000 0x2710 15 14 null not assignment read data...

Страница 20: ...xC6 6 0 id 0x80 15 7 0xC5 id cmd null 0 100 0x0000 0x0064 arc cut count null acr cmd 45 32 pr power monitor 0 10 000 0x0000 0x2710 NOTE cmd 0xFF id not assignment read data is 0 0x80 0 power output st...

Страница 21: ...andy Controller may a cause problem Display Area Liquid crystal display W 62 0 H 44 0 Resolution 128 64 Buttons A D Buttons and mini tact switch are used Key top is a panel sheet film Software determi...

Страница 22: ...unction displayed next to the corresponding button Functions correspond to A D Buttons from top to bottom EXT maintenance Mode Analog I O Control INT Internal Control State RS232 Communication Control...

Страница 23: ...le RF ON USET POWEr 1 is displayed when you press D button UFUNCU 2 it goes to power SETUP Screen 1 2 In the function setting screen select U OPERATEU 3 to move to U Operate Screen 3 From UOPERATE Scr...

Страница 24: ...he SLOWUP Screen 7 to move to Slow up setup screen 7 Slow up down setting can be operated using A button and B button 8 Press once to increase the setting to 50 Press once to decrease the setting to 5...

Страница 25: ...of the equipment Internal Control during Operation RF Output Method From USET POWER screen by pressing the Internal control button OUTPUT 9 The RF output confirmation screen is displayed 9 Confirmatio...

Страница 26: ...G5K13M PTS Co Ltd 26 10 11 Alarm Confirmation The error status on alarm confirmation screen of the RF power can be checked If an error occurs error checking screen is displayed Error confirmation scr...

Страница 27: ...rnal temperature rises and Temp sensor fail Check water flow and air flow around the rear of the generator and start again Water flow Temp Err Cover Err While generator is under operation if the Cover...

Страница 28: ...ccurrence or Analog Interface INT L is Open 9 2 Reflected Power Control The RF generator has a built in functionality to protect against Reflect Power 9 3 Maximum Output Control The RF Generator has e...

Страница 29: ...roducts delivered in South Korea Additionally repairs for failures due to the following will be require payment for service from the customer even within the warranty period 10 1 Cases of Warranty Exc...