T•FOLD
User Guide
Page 29
3.3
Choosing a Place for the
T•FOLD
3.3.1
Installation Environment Requirements
Choose a place for
T•FOLD
installation following the requirements of the table below.
Installation space
1.5m
2
or more, 1.3m or more is required for the length
Floor loading capability
Up to 3000Pa (450kgf/m2) or more
Electrical
specifications
Voltage
AC 100 V - 120 V ± 10% or AC 200 V - 240 V ± 10% (NOT auto-
switching)
Frequency
50/60Hz ± 1Hz
Capacity
Up to 4A or more
Environmental conditions
Temperature
Humidity
Operation environment
18º C (64F) to 30ºC (86F)
20% to 80%, with no
condensation
Printing accuracy range
18ºC (64F) to 25ºC (77F)
40% to 60%, with no
condensation
Rate of change
2ºC per hour or less
5% per hour or less
Do not place the
T•FOLD
in a location under the following conditions. Doing so
may cause the product to fall over, become damaged, or cause serious injury:
•
Unstable or shaky surfaces.
•
Slippery, slanted or angled surfaces.
•
Locations that are subject to vibration from other products.
Do not stand, or lean, on the
T•FOLD
or place any objects on it. Doing so may
cause it to fall over, become damaged, or cause injury.
Do not cover any ventilation holes or slots of the
T•FOLD
with anything at all.
Doing so could prevent the
T•FOLD
from ventilating and cause fire.
Keep the
T•FOLD
away from damp, humid or dusty areas. Failure to do so may result
in electrical shock or fire.
WARNING
TABLE 3-2 INSTALLATION ENVIRONMENT REQUIREMENTS