PT PT200M Скачать руководство пользователя страница 1

Innovative Measurement Electronics

...better value by design!

R

PT200M

Digital Indicator

Operator Manual

Содержание PT200M

Страница 1: ...Innovative Measurement Electronics better value by design R PT200M Digital Indicator Operator Manual...

Страница 2: ...ucts contained in this manual in order to improve design performance orreliability The information in this manual is believed to be accurate in all respects at the time of publication but issubject to...

Страница 3: ...4 3 1 User Interface Display and Controls 4 3 2 Operation Keys 5 3 3 Stability Considerations 7 3 4 Annunciators 8 4 BASIC WEIGHING 9 4 1 Normal Weighing 9 4 2 Using Tare 9 5 SPECIAL FUNCTIONS 10 5 1...

Страница 4: ...e versions only NSC approval 4000 divisions at 0 8 V division NMI approval 4000 divisions at 0 8 V division C tick approved and CE approved 1 2 Features Zero and Tare functionality as well as battery...

Страница 5: ...ed to the environmental conditions of use Pluggable equipment must be installed near an easily accessible power socket outlet To avoid the possibility of electric shock or damage to the instrument alw...

Страница 6: ...Operator Manual Rev 2 0 Page 4 003R 619 200 3 Basic Operation 3 1 User Interface Display and Controls...

Страница 7: ...ment cannot be turned off from the front keypad Battery Operation When using batteries the backlight will automatically turn off to conserve power after a short period of inactivity A short press of t...

Страница 8: ...sed to temporarily set the scale to zero such as cancelling the weight of a carton before performing a filling operation The display will show the Net weight and the Net annunciator will be lit The TA...

Страница 9: ...PRINT key will print the total The total weight is then cleared automatically FUNCTION The FUNCTION key is program mable to suit customer requirements A label identifying the special function will be...

Страница 10: ...not stable 1 Output 1 Visible when the output 1 is active 2 Output 2 Visible when the output 2 is active ZERO BAND Visible when the displayed weight is within the zero dead band setting The zero band...

Страница 11: ...rm Read the weight display 4 2 Using Tare The indicator displays zero with Zero annunciator lit Place the container on the weigh platform Press the TARE key The indicator will show the displayed zero...

Страница 12: ...d Place the sample pieces to be counted on the weigh platform Press and hold the COUNT key for two seconds The default number of pieces in the sample will be displayed Use the GROSS NET and PRINT keys...

Страница 13: ...g if it is currently being displayed 5 5 Peak Hold Press the PEAK key to show the largest absolute weight either positive or negative eg 30 is larger than 25 The instrument compares the current weight...

Страница 14: ...or ZERO key to clear any residual weight and return the scale to the zero state or Move the animal on to the weigh platform Once the weight moves outside the zero dead band the instrument begins to ca...

Страница 15: ...eight is too large to display in six digits the weight is shown in two sections labelled with the upper six digits displayed before the lower six digits Press and hold the PRINT key to cause the total...

Страница 16: ...The A TARE key is pressed to activate and deactivate the automatic tare mode Press and hold the A TARE key for two seconds The automatic tare threshold weight will be displayed Use the GROSS NET and P...

Страница 17: ...t 1 weight for editing Use the GROSS NET and PRINT keys to alter the setpoint 1 target weight and Press Set Pt The setpoint 1 target weight will be stored SETPT 2 will be displayed followed by the tar...

Страница 18: ...may damage mechanical scale elements Check the condition of load cell connections Check for damaged load cell ZERO ERROR The weight reading is beyond the limit set for Zero operation The operation of...

Страница 19: ...ust be spaced by at least 2 of full scale from each other RES LO The scale build is configured for less than 100 graduations Check the resolution count by and capacity settings RES HIGH The scale buil...

Страница 20: ...ibration information has been lost Re calibrate E0300 All setup information has been lost Enter setup and calibrate E0400 The factory information has been lost Return for Service E0800 The EEPROM memo...

Страница 21: ...Operator Manual Rev 1 0 003R 619 200 Page 19 Notes...

Страница 22: ...Operator Manual Rev 2 0 Page 20 003R 619 200 Notes...

Страница 23: ...Notes...

Страница 24: ...better value by design R Innovative Measurement Electronics http www pt global com...