Minox i Oxygen Transmitter User Manual
ProcessSensing.com
5
2.2 Connect Minox i
The Minox i oxygen transmitter is factory calibrated and will be ready to use when you unpack
it.
The oxygen transmitter operates from a two-wire industry-standard 4...20 mA loop-powered
supply, which you must be provide.
For flow-through connection, continue to "2.2.2 Flow-through process connection with dimen
2.2.1 KF-40 flange and tri-clamp process connections with dimensions
A suitable mating flange and seal/centering ringwill be required to install the KF-40 flange or
tri-clamp Minox i. These are not included in the pack.
Figure 4. Technical drawing of KF-40 flange and tri-clamp process connections
1. Place the seal/centering ring on the pipe where the Minox i will be installed.
2. Put the process connection end of the Minox i into the pipe.
3. Place your flange clamp or tri-clamp over the seal/centering ring and the Minox i where
they meet the pipe.
4. Fasten the flange or tri-clamp until finger-tight.
5. Continue to "2.2.3 Electrical connection" on page 7.
Electrical signal connector
KF-40 vacuum
flange fitting
Flange clamp
Seal/centering ring
53*
KF-40 base and pipe T-piece
*Height to suit depth of sensor
59
55
118.4
Ø37
39
54.8
47.7
10
BSPP 1/8 threaded
Dimensions are in mm unless otherwise stated.
Содержание PST-UM-2010-EN-02
Страница 1: ...Minox i Oxygen Transmitter User Manual PST UM 2010 EN 02 PST UM 2010 EN 02 ...
Страница 4: ...Minox i Oxygen Transmitter User Manual iv ProcessSensing com This page is intentionally blank ...
Страница 6: ...Minox i Oxygen Transmitter User Manual vi ProcessSensing com This page is intentionally blank ...
Страница 22: ...www ProcessSensing com ...