PS Engineering
PAC24 Series Audio Selector Panel and Intercom System
Installation and Operator’s Manual
200-240-0010
Page 1-3
Rev. 29, Sept. 2021
Specifications, Continued.
POWER REQUIREMENTS (Including Internal Lighting):
Voltage
:
11 to 33 VDC
Maximum Current
:
2.5 Amp (Externally protected by a 3 Amp circuit
breaker.)
Typical operating current
:
Speaker off:
Speaker on, 28V, full radio volume
350 mA
1.5 A
Audio Selector Specifications
Audio selector panel input impedance
:
510
Input Isolation
:
-60 dB (min.)
Speaker Muting
:
-60 dB (min.)
Speaker Output
(into 4
) with no clipping
14 VDC:
28 VDC:
3 Watts (min.)
10 Watts (min.)
Receiver Inputs
:
10
(Com 1, Com 2, Com 3, Com 4, Com 5, Nav 1,
Nav 2, ADF, DME, MKR)
Unswitched Inputs
:
2
(examples: GPS WPT, Value, Autopilot Discon-
nect, Altimeter DH)
Transmitter Selections
:
5
(Com 1, Com 2, Com 3 Com 4, Com 5)
Speaker Impedance
:
4 – 8
Headphone Impedance
:
150 – 1000
Headphone Output
:
38 mW each headset, no clipping <1% THD
120 mW each headset with < 10% THD into
150
Microphone Impedance
:
150 - 600
Intercom Specifications
Intercom Positions
:
Minimum of 5 places (with individual
Intelli
Vox® cir-
cuits)
Music Input
:
1 (Monaural)
Music Muting
:
>-30 dB "Soft Mute" when Com or intercom active.
Distortion:
<1% THD @ 38 mW into 150
<10% THD @ 120mW into 150
Mic Freq. Response, 3 dB:
300 Hz - 6000 Hz
Music Freq. Response, 3 dB
:
100 Hz - 18kHz
1.6
EQUIPMENT SUPPLIED
1 ea. of the following units:
Model
Description
Part Number
PAC24
PAC24 Audio Control Panel with intercom
050-240-0100
PAC24 Observer
PAC24 Audio Control Panel for Observer installation (3
rd
Transmit seat)
050-240-0400
PAC24 Vertical
PAC24 Audio Control Panel with intercom, Vertical Orientation
050-240-0500
PAC24 Special
PAC24 Audio Controller, Special Mission Version, Vertical
050-240-0503
PAC24 /NVG
PAC24 Audio Control Panel with intercom
050-240-8100
PAC24 Observer /NVG
PAC24 Audio Control Panel for Observer installation (3
rd
Transmit seat)
050-240-8400
PAC24 Vertical /NVG
PAC24 Audio Control Panel with intercom, Vertical Orientation
050-240-8500
Observer (-0400 & -8400) units
must
be dual installations, and
cannot be mixed with other part
numbers.