background image

 

User Manual 

MASTER - 

PCH-0001 

 

 

 

Содержание PCH-0001

Страница 1: ...User Manual MASTER PCH 0001...

Страница 2: ...0 3 1 General features 10 4 Operating Instruction 11 4 1 Mechanical assembly 11 4 2 Electrical connection 11 4 3 Device configuration via APP 14 4 3 1 Dashboard 18 4 3 2 Insights 19 4 3 3 Notification...

Страница 3: ...3...

Страница 4: ...he connection point and secure it against reactivation Before carrying out any work disconnect the power supplies using an installed disconnect switch Make sure that all conductors to be connected are...

Страница 5: ...ection Overvoltage e g in the event of lightning can be transmitted via the network cables inside the building and to other devices connected to the same network Make sure that all devices on the same...

Страница 6: ...factured and tested in accordance with IEC 61010 CAT III 300V This instruction manual contains safety warnings that must be observed by all users for a correct and safe use of the device It is mandato...

Страница 7: ...tage is higher than 300V in CAT III Do not disassemble the device and or use it disassembled All the instructions described in this manual must be carried out by qualified personnel only A qualified p...

Страница 8: ...4 Symbol table DANGER Causes serious injury or death WARNING It can cause serious injury or death ATTENTION It can cause minor or moderate injuries NOTICE It can cause damage to property Information N...

Страница 9: ...9 2 Product drawing 1 Live in 2 Neutral in 3 Live out 4 Neutral out 5 STATUS LED 6 COM LED 7 Button 8 Ground...

Страница 10: ...ady Blinking red Device not connected Blinking violet Professional mode activated 3 Technical features 3 1 General features Nominal Voltage 110 230 V AC Frequency 50 60 Hz Consumption 1 5 W Max Curren...

Страница 11: ...ntil the PRY CAM Home Master is in place 4 2 Electrical connection DANGER Danger of death from electrocution Potentially lethal voltages are present in live components Switch off the voltage at the co...

Страница 12: ...imum section of 6mm e current capacity higer than maximum current available on the system Assembly sequence Connect the live conductor L and the neutral conductor N to the device Connect the earth con...

Страница 13: ...13 Example of connection in which the main switch represents the main protection of the system...

Страница 14: ...ovided the device will operate in reduced mode using the NB IoT connection if present Configuration sequence 1 Check the completion of the MECHANICAL ASSEMBLY and ELECTRICAL CONNECTION steps 2 Downloa...

Страница 15: ...15 6 In the dashboard tap on Add PRY CAM Home 7 Enter the data of the device the contractual power of your system the country in which the device was installed and set if present the Wi Fi...

Страница 16: ...16 8 Enter the device data Enter the contractual power and the average cost per kilowatt hour you can found this information in your latest electricity bill...

Страница 17: ...ccess Point connection to your Wi Fi connection or to the cellular network connection If the configuration is not successful make sure you have entered the Wi Fi data correctly and that you have not o...

Страница 18: ...device icon you can view in the dashboard In the center is diplayed the graph of the power adsorbed by the grid In the bottom of the screen is shown the instant energy consumption the power quality t...

Страница 19: ...19 4 3 2 Insights In this screen is shown the detail of every insight For each of them it s possible to see the live daily weekly or monthly trend of the graph...

Страница 20: ...20...

Страница 21: ...Estimate emission CO2 Kg CO2 The estimate is calculated by multiplying the estimate consumption kWh by the coefficient 0 43 KgCO2 kWh Frequency Hz Frequency Min Max Media Hz Phase neutral Voltage Min...

Страница 22: ...lectrical grid Disconnection from the electricity grid Your system has been disconnected from the electrical grid LOAD 2 Powered system A load connected downstream of the system is correctly absorbing...

Страница 23: ...disconnect some loads from the system to avoid disruptions Alert over DIFFS 6 Danger The system has detected a device connected to the system that disperses a differential current step higher than tha...

Страница 24: ...anger of death from electrocution Potentially lethal voltages are present in live components Switch off the voltage at the connection point and secure it against reactivation Make sure that all conduc...

Страница 25: ...elp save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local autho...

Страница 26: ...writing to Prysmian Electronics S r l Via Chiese n 6 20126 Milano Italia The e mail references in the contact section of www prycamhome com 8 Declaration of conformity Prysmian Electronics S R L decla...

Страница 27: ...27 Prysmian Electronics S r l Via Chiese 6 20126 Milano Tel 39 02 6449 1 www prysmiangroup com www pry cam com...