4-5
VIBXPER
T II 05.2012
Results
Left:
Time signal in circular plot
Right:
Signal postprocessing
d
elta
: Show/hide delta cursor
Press 'Enter' to switch over between main and delta cursor. In
this case the measurement can only be repeated via the MENU
key (MENU - 'Remeasure')! The cursor coordinates indicate the
distance to the main cursor. The data field specifies the frequency
which corresponds to the distance between the main and delta cur-
sor (see below).
s
ideBands
: Show/hide sideband cursor
Select the number of sidebands. The spacing of the sidebands is set
by moving the outer cursor*. The position of the entire group can
be changed by moving the middle (main) cursor.
Cartesian / circular plot
By default, the time waveform is displayed in a Cartesian plot (XY
diagram). However, you can change the display to a circular plot. This
is useful when the gear mesh in a gear stage is to be emphasized, for
example. In this type of display, the measured time interval is pro-
jected on a circle, so that the start and end times are directly adjacent
to one another. If the shaft rotates by 360° within the measured time
interval, the circular diagram shows the signal for one complete rota-
tion of the shaft.
• Press the F key to toggle the two diagram types (see below).
Signal post processing
Calculating the characteristic overall values from the signal
The following overall values can be calculated:
- Maximum / minimum amplitude,
- Arithmetic mean, p-p value, RMS value, Crest factor.
• Press the MENU key in the result screen.
• Select ‘Postprocessing’ and click on ‘Compute overall values’.
* press 'Enter' to switch between the
main and the outer cursor.