![PRÜFTECHNIK VIBXPERT II Скачать руководство пользователя страница 170](http://html.mh-extra.com/html/pruftechnik/vibxpert-ii/vibxpert-ii_operating-instructions-manual_1621896170.webp)
6-20
VIBXPER
T II 05.2012
Module
Operat. mode
Measurement type
Remarks
Basic
,
Default registration
Multimode
• Overalls - vibration (a, v, s)
• Overalls - user (current / voltage, each
in AC / DC)
• Bearing condition
• Rotational speed
• Temperature
• FFT spectrum (v)
FFT spectrum:
1. two factory-set tasks*
2. only main cursor, no postprocessing
3. Option ‘New task’ not available
E-Registration
(1-channel)
VIB 5.318-E
Multimode
Route
• FFT spectrum (a, v, s, AC)
• Envelope spectrum
• Time waveform (a, v, s, AC)
• Multi task
In Route mode only:
• TrendingSpectrum
• Envelope TrendingSpectrum
• Order spectrum
• Manual input
• Visual inspection
MultiTask:
Only with registered measurement tasks
Route :
Only with registered measurement tasks
1-channel
VIB 5.311
Multimode
Route
Machine templates
• FFT spectrum (a, v, s, AC)
• Envelope spectrum
• Time waveform (a, v, s, AC)
• Multi task
In Route mode only:
• TrendingSpectrum
• Envelope TrendingSpectrum
• Order spectrum
• Manual input
• Visual inspection
Special analyses:
• Phase measurement
• Coast-down/ Run-up (overalls, phase,
spectrum)
• Shaft centerline plot
• Impact test
MultiTask:
Only with registered measurement tasks
Route / template :
Only with registered measurement tasks
2-channels
VIB 5.311-CH2
--
• 1+1 measurement
• 2-channel measurements for Overalls,
Time waveform, Spectrum
• Phase measurement, 2-channel
• Phase measurement, cross-channel
• Orbit, filtered / unfiltered
• Cepstrum
--
Modal analysis
VIB 5.319-ODS
--
• Impact test with impulse hammer
• ODS
1-channel and 2-channel module must be
registered
Recording
VIB 5.315-REC
--
• Recording function
• Time waveform recorder for longterm
data collection
For Time waveform recorder the 1-channel
meas. or the E-Registration module is required
Balancing
VIB 5.316-BAL
Multimode
Balancing
Diagnosis, Balancing:
• Phase measurement, 1-/ 2-channel
• FFT spectrum (v)
• Time waveform (v)
• Rotational speed
• Overalls - vibration (v)
Balancing in one or two planes
*Factory-set tasks in the 'Basic' module:
Velocity spectrum / 2-400Hz / 1600 lines / df=0,25 Hz
Velocity spectrum / 2-1600Hz / 1600 lines / df=1 Hz
VIBXPERT Firmware modules
Appendix - firmware modules
Содержание VIBXPERT II
Страница 175: ......