Microcontroller-controlled temperature difference controller for solar thermal systems

Operating manual

Sunny Scout 1328

Содержание Sunny Scout 1328

Страница 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Sunny Scout 1328...

Страница 2: ...7 1 2 Thermostat 8 7 1 3 RPM control 8 7 2 Protective functions 8 7 2 1 Anti freeze protection Jumper on 8 7 2 3 System protection 8 7 2 3 Pump blocking protection 8 8 System monitoring 9 8 1 Sensor...

Страница 3: ...onnection box Immersion sleeves 2 Safety instructions Always completely disconnect the device from the operating voltage before performing installation or wiring work on the electrical equipment Never...

Страница 4: ...nductor terminals N are electrically connected and are not switched The switching output A1 is electronic 230V N O contact If potential free contacts are required the appropriate corresponding accesso...

Страница 5: ...side of the housing using a suitable tool Briefly pressing the button switches the controller from the Info menu to the Basic Setup menu Here you can scroll through and select the variables and infor...

Страница 6: ...nge Factory setting Current setting max 65 C Storage tank Maximum permissible tempe rature 15 95 C 60 C dT max 7 K Storage tank Switch on difference 3 40K 10K dT min 3 K Storage tank Switch off differ...

Страница 7: ...Mains phase N Neutral conductor mains and outputs A1 Solar circuit pump switching output 1 Sensor connections S1 Collector sensor S2 Lower storage tank Switch positions Temp diff controller all off H...

Страница 8: ...he output A1 can be operated using an RPM control Minimum 30 7 2 Protective functions The controller is equipped with the following protective functions 7 2 1 Anti freeze protection This function must...

Страница 9: ...s that are automatically detected by the controller and therefore can be displayed using error messages Faults that the controller cannot detect 9 1 Faults with error messages LED s Display Meaning Me...

Страница 10: ...230V compo nents for short circuits Defect device Contact the supplier Output is not switched on Switch on condition is not fulfilled Wait until switch on condition is satisfied Pump symbol rotates b...

Страница 11: ...cording to EN 60730 DIN VDE 0631 IEC 60664 IEC Output Voltage Power switching output 230V 1A approx 230VAfor cos 0 7 1 0 Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fuse Misc...

Страница 12: ...itory action reduction of price is excluded Warranty claims may only be submitted by the customer and are non transferable If a defect occurs during the warranty period please contact the supplier ins...