GTW1500HF Grid Inverter   

Operation Manual 

 

 

 

 

Содержание GTW1500HF

Страница 1: ...GTW1500HF Grid Inverter Operation Manual...

Страница 2: ...arranty or liability claims for all kinds are excluded in case of damages due to Inappropriate use of the product Operation of the product in an improper environment Operation of the product without c...

Страница 3: ...ct Please read these sections carefully in order to avoid any damages of the equipment and for optimal personal protection Note This symbol indicates information that is required for the optimal opera...

Страница 4: ...ace 13 4 3 4 Auto test display interface 14 5 Installation requirements 17 5 1 Installation requirements 17 5 1 1 Ambient conditions 17 5 2 Position 18 5 3 Installation 18 6 Electrical connection 20 6...

Страница 5: ...The GTW1500 HF is equipped with the ProVista grid guard This is a type of independent disconnection device It ensures that the GTW1500 HF complies with the IEC AS regulations for the connection and p...

Страница 6: ...electrician Hazardous and even lethal voltages can be encountered within the enclosure Before working on the GTW1500 HF with the lid removed the AC and DC voltages MUST be disconnected from the GTW15...

Страница 7: ...minute Beware of hot surface The inverter can become hot during operation Avoid contact during operation Caution risk of danger Observe all documentation that accompanies the inverter The inverter mu...

Страница 8: ...tem consists of PV arrays photovoltaic combiner box photovoltaic grid connected inverter metering devices and utility grid see figure 3 1 Figure 3 1 PV Grid connected system Note Need permission from...

Страница 9: ...ogy for maximum power point tracking MPPT 99 MPPT efficiency Wide input voltage range Efficient design of high frequency isolation transformer High efficiency at wide power range Advanced anti islandi...

Страница 10: ...rning if sufficient insolation is available and therefore if a certain minimum voltage is present in the inverter If as nightfall approaches the voltage drops below the minimum voltage value gird fee...

Страница 11: ...f inverter from these lights The states of each LED light signals are in the following table LED Color Status Green RUN means normal operation Yellow STARTING means start operation Red ALARM means ove...

Страница 12: ...go into the Checking LCD screen display as Menu 3 it also shows another if the progress is updated Menu 3 Checking Yellow LED display Checking 4 3 2 Operating parameters display interface About 2 sec...

Страница 13: ...7 display interface Menu 9 to Menu 15 it also shows another if the progress is updated Menu 9 RED LED display PV Array Voltage Out of range Menu 10 RED LED display DC Component Out of range Menu 11 RE...

Страница 14: ..._Grid Inverter Display Ver 1 10 Control Ver 1 10 Please beat the panel Auto Test Please beat the panel Auto Test Start Grid Volt High Protection 261V Grid Volt High Protec Max 262V Grid Volt High Prot...

Страница 15: ...High Protection 51 0Hz Grid Freq High Protection 50 9Hz Grid Volt Low Protection 187V Grid Volt Low Protection 188V Grid Volt Low Protection 230V Grid Volt Low Prote Pass 230V Grid Volt Low Protec Mi...

Страница 16: ...Low Prote Pass 50 1Hz Grid Freq Low Prote Time 40ms Test Finish Grid Freq Low Prote Min49 0Hz Grid Freq Low Protection 49 0Hz Grid Freq Low Protection 49 1Hz Grid Freq Low Protection 50 1Hz Grid Freq...

Страница 17: ...The GTW1500 HF should be installed in a place where it is not exposed to direct sunlight An increased ambient temperature can reduce the yield of the PV system Provide better ventilation for GTW1500 H...

Страница 18: ...sides 40cm In front 40cn 5 2 Position The GTW1500 HF is designed to be mounted on a vertical wall For an optimum energy yield and the most convenient operation vertical installation at eye level is p...

Страница 19: ...stallation position The space between every every holes is shown as below photo Keep drilling vertical to the wall and don t shake the drill to avoid holes tilting 2 Please fix the wall bracket on the...

Страница 20: ...ecifications Before installation please reference the wires recommended sizes as below table Wire Requirements AWG PV DC wire 12AWG PV DC wire 12AWG GND wire 12AWG Grid L wire 12AWG Grid N wire 12AWG...

Страница 21: ...diameter between 7mm and 12mm as below photo showing 4 Connect the individual conductors into the socket s terminals with correct polarity and position as below photo showing and make sure the wires a...

Страница 22: ...ocket is fully assembled 6 3 PV connection steps Warning Make sure the PV array to be negative grounding The PV generator strings are connected directly to the terminal in the connection box Connect t...

Страница 23: ...sure that no voltage is present at the cable Connection procedure 1 Parts of the positive plug 2 Proceed the cable as below photo showing 3 Connect the positive pin and rivet line together as below p...

Страница 24: ...o showing insert the cable with riveting pin pic2 into the main unit it is appropriate when you hear the sound after inserting please have a anti pull to double check if matched firmly 7 As the below...

Страница 25: ...he input side of inverter add an AC circuit breaker at the output side of inverter And the requirement models of breakers as table Breakers Requirement model DC Breaker 600VDC 16A AC Breaker 400VAC 10...

Страница 26: ...he maximum string voltage of 400 V DC Warning If the voltage of the PV modules the maximum input voltage of the inverter it can be destroyed by the overvoltage This will void all warranty claims Do no...

Страница 27: ...mation page 6 7 1 Opening the GTW1500 HF Follow the sequence below under all circumstances 1 Switch the line circuit breaker to the off position 2 Disconnect the PV generator from the GTW1500 HF 3 Wai...

Страница 28: ...the voltages between one DC plug connector of a string and earth potential Pay attention to the safety warnings Warning Dangerous high voltages may be present Danger of death 5 the measured voltages...

Страница 29: ...tors that affect all varistors in a similar way temperature age inductive overvoltages it is highly recommended that you replace both varistors not just the one that is obviously defective The varisto...

Страница 30: ...ltage Uac 200 260 V AC Nominal grid frequency 50Hz Operating range grid frequency f 49 51 Hz AU 47 5 50 2Hz Germany Total Harmonic Distortion 5 to Standard EMI compliant with CE AS4777 Standard All po...

Страница 31: ...r GTW1500 HF without express authorization and instructions 10 Contact In the case of complaints or faults we request that you contact the local supplier from whom you got this product installed They...

Страница 32: ...32 11 Appendix A Model Number Conversion Table Descriptions Model Number For Protronic use Model Name For provista use 1500W Grid Connected inverter SGA015 GTW1500HF...