background image

31

Chapter 4 Data Editing

Introduction

This chapter describes how to add prefixes and suffixes.

• Default prefix = None. Default suffix = None.

• A prefix or suffix may be added or cleared from one symbologyor

all symbologies.

• You can add any prefix or suffix from the ASCII Conversion Chart

deplus Code I.D. and AIM I.D.

• Enter prefixes and suffixes in the order in which you want them to appear

on the output.

• When setting up for specific symbologies (as opposed to all

symbologies), the specific symbology ID value counts as an added prefix

or suffix character.

• The maximum size of a prefix or suffix configuration is 200 characters,

which includes header information.

Содержание ICS-1290

Страница 1: ...2D Proton ICS 1290...

Страница 2: ...ufacturer is not responsible for any loss or claim arising from theuse of this manual by a third party 5 Do not throw or drop the barcode scanner or subject it to strong impact Doing so can damage the...

Страница 3: ...ading 16 Defaults Setting 17 User defined Settings 17 Factory Default Setting 17 Delete User defined Settings 18 Chapter 2 Interface Type 19 Introduction 19 RS232 19 RS232 Baud Rate 20 RS232 Word Leng...

Страница 4: ...Return Suffix to All Symbologies 35 Clear Prefix or Suffix 35 Prefix Selections 36 Suffix Selections 36 Function Code Transmit 37 Intermessage Delay 37 Chapter 5 Data Formatting 38 Introduction 38 Ad...

Страница 5: ...Check Digit 58 Message Length 60 NEC 2 of 5 61 On Off 61 Check Digit 61 Message Length 63 Code 93 64 On Off 64 Message Length 64 Straight 2 of 5 Industrial three bar start stop 65 On Off 65 Message Le...

Страница 6: ...nda Separator 76 UPC E0 77 On Off 77 Expand 78 Addenda Required 78 Addenda Separator 78 Check Digit 79 Number System 80 Addenda 80 UPC E1 81 EAN JAN 13 81 On Off 81 Check Digit 82 Addenda 82 Addenda R...

Страница 7: ...95 On Off 95 Message Length 95 Aztec Code 96 On Off 96 Message Length 96 China Post Hong Kong 2 of 5 97 On Off 97 Message Length 97 Korea Post 98 On Off 98 Message Length 98 Check Digit 98 Chapter 7...

Страница 8: ...9 2D Symbologies 105 Postal Symbologies 106 ASCII Conversion Chart 107 Sample Symbols 111 Programming Charts 114...

Страница 9: ...rted in thismanual 1 Chapter 2 Interface Type 2 Chapter 3 input and output settings Good Read Delay 3 Chapter 5 Data Formatting 4 Chapter 6 Symbologies code 39 Full ASCII UPC E1 The barcode scanners a...

Страница 10: ...fix suffix Chapter 5 Data Formatting Introduce the addition and editing of data formats Chapter 6 Symbologies Introduce all the code systems and configurations supported by barcode scanners Chapter 7...

Страница 11: ...t packaging perform the followingsteps Remove the scanner and its accessories and inspect for damageduring shipment Make sure the items in the carton match your order If there are any damaged or missi...

Страница 12: ...your computer 1 Connect the device interface RJ45 connector of the USB cableto the device 2 Connect the host interface USB interface of the USB cable to the host 3 The barcode scanner is humming 4 Ver...

Страница 13: ...interface end PS 2 interface of the PS 2 data cable to the host 3 Connect the PS 2 cable to the power adapter if needed 4 If necessary connect the normal keyboard to the PS 2 datacable host interface...

Страница 14: ...to the scanner 2 Connect the host interface RS 232 interface of the RS 232 cable to the host 3 The barcode scanner is humming 4 Verify the operation by scanning the Sample Symbols at the end ofthis ma...

Страница 15: ...anner is closer to the code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mi...

Страница 16: ...have been set and you want to change a setting by simply scanning the new settings to overwrite the old ones For example if you have saved the beep sound volume to low as user defined and decided to...

Страница 17: ...ave changed some settings and want to restore the barcode scanner to the factory defaults first scan the Delete User defined Settings barcode and then scan Load Factory Defaults barcode This will rese...

Страница 18: ...d RS232 interface types and lists their related configurations RS232 Connect RS232 interface you need to scan the RS232 barcode the serial port related configuration is 115200 baud rate 8 data bits no...

Страница 19: ...he data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115200 8310030 300 8310031 600 8310032 1200 8310033 2400 8310...

Страница 20: ...bits and you must set the terminal to the same data bit as the barcode scanner to communicateproperly Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking ch...

Страница 21: ...8310064 7 Data 2 Stop Parity Even 8310061 7 Data 2 Stop Parity None 8310065 8 Data 1 Stop Parity Even 8310068 8 Data 1 Stop Parity Odd 8310067 7 Data 2 Stop Parity Odd 8310062 8 Data 1 Stop Parity No...

Страница 22: ...des you must power cycle thecash register 881001128 USB IBM SurePos USB Handheld Scanner Interface 881001129 USB IBM SurePos USB Tabletop Scanner Interface USB PC Keyboard Scan one of the following co...

Страница 23: ...Serial 881001131 USB HID BarCode Scanner Scan the following code to program the scanner to emulate a regular RS232 based COM Port 881001130 USB Serial Note No extra configuration e g baud rate isnece...

Страница 24: ...button Startup Beeper The scanner can be programmed to beep when it s started up Default Startup Beeper On 8410130 Startup Beeper Off 8410131 Startup Beeper On Trigger Click Beeper To hear an audible...

Страница 25: ...Off in response to a good read Default Good Read Beeper On 8410010 Good Read Beeper Off Good Read Beeper Volume 8410011 Good Read Beeper On The beeper volume codes modify the volume of the beep thesca...

Страница 26: ...dium 2400 Hz 8410064200 High 4200 Hz Good Read Beeper Duration The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal 8410020 Normal Error Read Beeper...

Страница 27: ...8 8410073250 Medium 3250 Hz 8410074200 High 4200 Hz Good Read LED The LED indicator can be programmed On or Off in response to a good read Default On 8410081 Good Read LED On 8410080 Good Read LED Off...

Страница 28: ...Short Delay 750 ms 8510060 No Delay 851006750 Short Delay 750 ms 8510061000 Medium Delay 1 000 ms Manual Trigger Mode 8510061500 Long Delay 1 500 ms When in manual trigger mode the scanner scans until...

Страница 29: ...r scanner is optimized to read barcodes from mobile phone or other LED displays However the speed of scanning printed barcodes may be slightly lower when this mode is enabled 801031 Hand Held Scanning...

Страница 30: ...d any prefix or suffix from the ASCII Conversion Chart deplus Code I D and AIM I D Enter prefixes and suffixes in the order in which you want them to appear on the output When setting up for specific...

Страница 31: ...anual or scan 9 9 for all symbologies Step 4 Determine the hex value from the ASCII Conversion Chart for the prefix or suffix you wish to enter Step 5 Scan the 2 digit hex value from the Programming C...

Страница 32: ...mbology Charts for code 128 Step 3 Scan 6 3 from the Programming Chart inside the back cover of this manual Step 4 Determine the hex value from the ASCII Conversion Chart for the CR carriage return St...

Страница 33: ...34 800002 Save...

Страница 34: ...prefixes and suffixes for singlesym bologies you can use Clear One Prefix Suffix to delete a specific char acter from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for...

Страница 35: ...36 Prefix Selections 889002 Add Prefix 889003 Clear All Prefixes Suffix Selections 888002 Add Suffix 888003 Clear All Suffixes 889004 Clear One Prefix 888004 Clear One Suffix...

Страница 36: ...s increments may be placed between each scan transmission Scan theIntermessage Delay barcode below then scan the number of 5ms delays and the Save barcode using the Programming Chart inside the back c...

Страница 37: ...output Default Data Format None Normally when you scan a barcode it gets outputted automatically howeverwhen you create a format you must use a send command Data Format Editor Commands within the for...

Страница 38: ...for an PC Keyboard Note The wildcard for all terminal types is 099 Step 4 Code I D In the Symbology Charts find the symbology to which you want to apply the data format Locate the Hex value for that...

Страница 39: ...can the three digital barcodes in the appendix ofthis manual Scan the 1 3 0 barcodes to indicate USB serial Step 4 Select the code 128 to add the data format In the Symbology Charts find the hexadecim...

Страница 40: ...e Programming Chart Step 7 Scan Save to save your data format or Discard to exitwithout saving your changes Step 8 Scan the selected data format Data Format 1 barcode forthe configuration to take effe...

Страница 41: ...ne symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or3 depending ontheformatyou...

Страница 42: ...formatchanges 886004 Clear One Data Format 800002 Save Terminal ID Table 886003 Clear All Data Formats 800000 Discard Terminal IBM Model s PC AT and compatibles Terminal ID 003 USB SurePOS Handheld S...

Страница 43: ...Command format E9nn nn 00 99 the length of the lastcharacter not output Outputs all characters from the right side of the cursor to the front of the last nn characters left side The cursor moves to t...

Страница 44: ...between these formats Your primary data format is saved under 0 Other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the barcodes below 8850010 Prim...

Страница 45: ...he barcode typesthatwill notbe used toimprovetheperformanceofthebarcodescanner This programming section contains the following menuselections AllSymbologies Codabar Code39 Interleaved 2 of5 NEC 2 of5...

Страница 46: ...nner will issue an error tone You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length barcode data This helps reduce the chances of amisread EXAMPLE...

Страница 47: ...Start Stop characters identify the leading and trailing ends of the barcode Youmay either transmit or not transmit Start Stop characters Default Don t Transmit 9000061 Transmit Check Character 9000060...

Страница 48: ...haracter at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read Codabar barcodes printed with a check character but will not transmit the che...

Страница 49: ...a symbol having a D stop character In this case the two mes sages are concatenated into one with the D charactersomitted A 1 2 3 4 D D 5 6 7 8A Select Require to prevent the scanner from decoding a si...

Страница 50: ...des below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 900005 Minimum Message Lengt...

Страница 51: ...ettings Code 39 On Off 9010011 On 9010010 Off Start Stop Characters Start Stop characters identify the leading and trailing ends of the barcode You may either transmit or not transmit Start Stop chara...

Страница 52: ...heck Character is set to Validate and Transmit the scanner only reads Code 39 barcodes printed with a check character and will transmit thischaracter at the end of the scanned data Default No CheckCha...

Страница 53: ...54 901007 Maximum Message Length...

Страница 54: ...buffers Code 39 barcodes until it reads a Code 39 barcode that does not have the append trigger The data is then transmitted in theorder in which the barcodes were read FIFO Default Off 9010021 On Ex...

Страница 55: ...56 Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used byItal ian pharmacies This symbology is also known as PARAF 9010051 On 9010050 Off...

Страница 56: ...R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8 H H X X h H...

Страница 57: ...ut a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads Interleaved 2 of 5 barcodes printed with a check digit but will not transmit the check digit with the scanne...

Страница 58: ...59 9020012 Validate and Transmit 9020011 Validate but Don t Transmit...

Страница 59: ...odes below to change the message length Refer to Message Length Description for additional information Minimum and Maximumlengths 2 80 Minimum Default 4 Maximum Default 80 902004 Minimum Message Lengt...

Страница 60: ...a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads NEC 2 of 5 barcodes printed with a check digit but will nottransmit the check digit with the scanned data When...

Страница 61: ...62 9030022 Validate and Transmit 9030021 Validate but Don t Transmit...

Страница 62: ...odes below to change the message length Refer to Message Length Description for additional information Minimum and Maximumlengths 2 80 Minimum Default 4 Maximum Default 80 903004 Minimum Message Lengt...

Страница 63: ...9040021 On 9040020 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 0 80 Minimum Defau...

Страница 64: ...Industrial three bar start stop Settings On Off 9050011 On 9050010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional informati...

Страница 65: ...TA two bar start stop Settings On Off 9060011 On 9060010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum...

Страница 66: ...s On Off 9070011 On 9070010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Mini...

Страница 67: ...00 Default All Code 11 Settings On Off 9080021 On 9080020 Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11barcodes Default Two Check Digits 3110280 One...

Страница 68: ...des below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 908004 Minimum Message Lengt...

Страница 69: ...70 Code 128 Default All Code 128 Settings 909000 Default All Code 128 Settings On Off 9090011 On 9090010 Off ISBT 128 Concatenation 9020051 ISBT 128 On 9020050 ISBT 128 Off...

Страница 70: ...des below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 909003 Minimum Message Lengt...

Страница 71: ...9100011 On 9100010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Defau...

Страница 72: ...9110011 On 9110010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 60 Minimum Defau...

Страница 73: ...ings 9120031 On 9120030 Off Note When UPC A Off is scanned UPC A barcodes are transmitted as EAN 13 Check Digit This selection allows you to specify whether the check digit shouldbe transmitted at the...

Страница 74: ...the unit can be programmed so itwill not transmit it Default On 9120051 On Addenda 9120050 Off This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5...

Страница 75: ...denda You must then turn on a 2 or 5 digit addenda Default NotRequired 9120061 Required Addenda Separator 9120060 Not Required When this feature is on there is a space between the data from the barcod...

Страница 76: ...ult All UPC E0 Settings On Off Most U P C barcodes lead with the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1number system use UPC E1...

Страница 77: ...ed When Required is scanned the scanner will only read UPC E barcodes that have addenda Default Not Required 9140031 Required Addenda Separator 9140030 Not Required When this feature is On there is a...

Страница 78: ...79 9140040 Off Check Digit Check Digit specifies whether the check digit should be transmitted atthe end of the scanned data or not Default On 9140051 On 9140050 Off...

Страница 79: ...rogrammed so it will not transmit it To prevent transmission scan Off Default On 9140061 On Addenda 9140060 Off This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for b...

Страница 80: ...es that lead with the 1 number system use the UPC E1 On selection Default Off 9140091 UPC E1 On 9140090 UPC E1 Off Default All EAN JAN Settings 915000 Default All EAN JAN 13 Settings On Off 9150011 On...

Страница 81: ...nd of the scanned data or not Default On 9150021 On 9150020 Off Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 DigitAddenda 9150...

Страница 82: ...9150050 Not Required Addenda Separator When this feature is On there is a space between the data from the barcode and the data from the addenda When turned Off there is no space Default On 9150061 On...

Страница 83: ...84 9150070 Off...

Страница 84: ...011 On 9160010 Off This selection allows you to specify whether the check digit should betransmitted at the end of the scanned data or not Default On 9160021 On 9160020 Off Addenda This selection adds...

Страница 85: ...denda Off 9160041 5 Digit Addenda On 9160040 5 Digit Addenda Off Addenda Required When Required is scanned the scanner will only read EAN JAN 8 barcodes that have addenda Default Not Required 9160051...

Страница 86: ...87 When this feature is On there is a space between the data from the barcode and the data from the addenda When turned Off there is no space Default On 9160061 On 9160060 Off...

Страница 87: ...88 MSI On Off 9170011 On Default All MSI Settings 917000 Default All MSI Settings 9170010 Off...

Страница 88: ...end of the scanned data When Check Character is set to Validate MOD 10 but Don t Transmit the unit will only read MSI barcodes printed with the specified type check character s but will not transmit...

Страница 89: ...90 917003 Maximum Message Length...

Страница 90: ...ar Omnidirectional Settings 918000 Default All GS1 DataBar Omnidirectional Settings On Off 9180011 On GS1 DataBar Limited 9180010 Off Default All GS1 DataBar Limited Settings 919000 Default All GS1 Da...

Страница 91: ...ed Settings On Off 9200011 On 9200010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths...

Страница 92: ...011 On Message Length 9240010 Off Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 2750 Minimum Default...

Страница 93: ...QR Code and Micro QR Code 9280011 On Message Length 9280010 Off Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum...

Страница 94: ...ettings 9300011 On Message Length 9300010 Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 3116 Minimum...

Страница 95: ...f 9310011 On Message Length 9310010 off Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 3832 Minimum D...

Страница 96: ...g Kong 2 of 5 Settings On Off 9360011 On 9360010 Off Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maxi...

Страница 97: ...the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 937003 Minimum Mess...

Страница 98: ...99 at the end of the scanned data Default Don t Transmit 9370041 On 9370040 Off...

Страница 99: ...100 Chapter 7 Utilities Show Software Revision Scan the barcode below to output the current software revision unit serialnumber and other product information 809005 Show Revision...

Страница 100: ...s garbled it may be that the data reception speed of the device does not match the output speed of the barcode scanner Problem Barcode scanner does not decode some barcodes possible reason 1 The barco...

Страница 101: ...r with poor paper quality for a long time it willdamage the surface finish of the window and affect the reading effect ofthe barcode scanner 2 The outer shell of the barcode scanner can be wiped with...

Страница 102: ...68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3...

Страница 103: ...t Hong Kong 2 of 5 X0 Q 51 Interleaved 2 of 5 Im 0 1 3 e 65 Matrix 2 of 5 X0 m 6D NEC 2 of 5 X0 Y 59 Straight 2 of 5 IATA Rm 0 1 3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 g 67 Telepen Bm t...

Страница 104: ...e Code Han Xin Code X0 H 48 Codablock A O6 0 1 4 5 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirect...

Страница 105: ...ian Post X0 A 41 British Post X0 B 42 Canadian Post X0 C 43 Symbology AIM ID Possible Modifiers m ID Hex China Post X0 Q 51 InfoMail X0 2c Intelligent Mail Barcode X0 M 4D Japanese Post X0 J 4A KIX Ne...

Страница 106: ...Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK N...

Страница 107: ...2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sig...

Страница 108: ...Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket 5e 94 Caret Circumflex 5f 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j...

Страница 109: ...110 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete...

Страница 110: ...111 Sample Symbols UPC A 01234567890 Interleaved 2 of5 Code 128...

Страница 111: ...112 Code 93 123456 9 Straight 2 of 5Industrial 123456 Matrix 2 of 5 6543210 GS1DataBar PDF417 0100123456789012 Codabar...

Страница 112: ...113 Data Matrix QRCode Numbers Aztec MaxiCode Test Message TestSymbol Micro PDF417 Test Message...

Страница 113: ...114 Programming Charts S0S 0 S2S 2 S4S 4 S6S 6 S1S 1 S3S 3 S5S 5 S7S 7...

Страница 114: ...115 S8S 8 S9S 9...

Страница 115: ...0002 Save SBS B SDS D SFS F 800000 Discard Note If an error occurs while scanning a letter or number before scanning the Save barcode scan the Discard barcode rescanthe correct letter or number and th...