Proteco Electric Lock & Interface Card Installation for Q71A & B
Components Required:
1 x Horizontal Lock
1 x MEL 56 Interface Card
1 x 2 core CAT5 / Alarm Cable
Installing the Lock onto the Gate
For Double Gates: Fit the horizontal lock on the leading edge of the
leaf that will be opening first and closing second. Fit the striker plate
onto the gate that opens second and closes first.
For Single Gates: Fit the horizontal lock on the leading edge of the
gate and fir the striker plate onto the post or pillar that the gate is
closing up to.
Dimensions of Horizontal Lock
Measurements in millimetre (mm)
Barrel length is 50mm long with a 25mm diameter