protech QM7410 Скачать руководство пользователя страница 1

1.Description

Compact Non-Contact Thermometer

QM7410

User Manual

Thank you for purchasing the QM7410. This product is capable of non-contact (infrared)

temperature measurements at the touch of a button. The built-in laser pointer increases target 

accuracy while handy push-buttons combine for convenien , ergonomic operation. The QM7410 

can be used to measure the temperature of objects with a surface that cannot be measured by

traditional contact thermometers. Proper use and care of this meter will provide years of usage.
2.Features

• Rapid Detection Function

• Precise Non-Contact Measurements

• Single Laser Sighting

• Unique Flat Surface, Modern Housing Design

• Automatic Data Hold

• “MAX/MIN” Function

3.Wide Range Application

Food preperation, safety and fire inspectors, plastic molding, asphalt, marine, screen printing,

measure ink and dryer temperature, HVAC/R, diesel and feet amaintenance, etc.

4.Safety

• Use extreme caution when the laser beam is turned on.

• Do not let the beam shine onto your or others eyes.

• Be careful not to let the beam reflect off of a surface and into your eyes.

• Do not allow the laser light beam impinge on any gas which can explode.

5.Distance & Spot Size

6.Specifications

Temperature Range:

-50 to 500°C (-58 to 932°F)

D:S:

12:1

Display Resolution:

0.1°C (0.1°F)

Emissivity:

Fixed at 0.95

Accuracy:

±3°C (5.4°F) at -50 to 20°C (-58 to 68°F),

±2.0% ±2°C (3.6°F) at 20 to 500°C (68 to 932°F)

Repeatability:    

±1°C (1.8°F)

Response Time:    

500ms

Spectral Response: 

8~14um

Over Range Indication: 

LCD will show “----”

Diode Laser: 

Output <1mW; Wavelength 630~670nm; Class 2 laser product

Operating Temperature:   0 to 50°C (32 to 122°F)

Storage Temperature: 

-10 to 60°C (14 to 140°F)

Relative Humidity:  

10% to 90%RH operating; <80%RH storage

Power:  

9V Battery (Included)

Note:

    Field of View: Make sure that the target is larger than the units spot size. The smaller the 

target, the closer you should be to it. When accuracy is critical, make sure the target is at 

least twice as large as the spot size. 

7.Panel Description

1-Laser

2-Infrared Sensor

3-Display Screen

4-°C/°F Button

5-Laser/Backlight Button

6-Max/Min Button

7-Power On/Measure Button (Automatic switch off after 10 seconds)

8-Battery Cover

ATTENTION

LASER RADIATION

DO NOTSTARE INTOTHE BEAM

LASER DIODE

Wavelength 630-670nm

Max. output power: <1mW  

CLASS 2 LASER PRODUCT  EN 60825-1:2014

Distance : Spot = 12:1

0.5in@6in 1.0in@12in

12.5mm@152mm

25mm@305mm

6

7

1

2

3

4

5

8

Distributed by:

Reduction Revolution Pty Ltd

 

www.reductionrevolution.com.au

Отзывы: