Protec PRO-8-1000-MSP Скачать руководство пользователя страница 1

Dwg. No. 101022 

1000 PSI

Rev. C/2 

MEGA-SIDE PORT 

ENGINEERING DRAWING PACKET 

MODEL PRO-8-1000-MSP 

DESIGN PRESSURE at 120ºF   

1000 PSI 

MINIMUM OPERATING TEMP.* 

20ºF 

MAXIMUM OPERATING TEMP. 

120ºF 

FACTORY TEST PRESSURE   

1100 PSI 

BURST 

PRESSURE 

  6000 

PSI 

OPERATING pH RANGE 

 

3-11 

CLEANING pH RANGE  

 

2-12 

(less than 30 minutes) 

APPLICATION  

TYP.   SEAWATER 

 

 

INTENDED USE

The

 

PROTEC Model PRO-8-1000-MSP Pressure Vessel

 is 

designed for continuous use as a housing for membrane filtration 
elements to purify typical seawater waters at any positive 
pressure up to 1000 PSI. The 

PRO-8-1000-MSP

 will 

accommodate any make of eight-inch nominal diameter spiral-
wound element as well as many hollow fiber elements. The 
element interface hardware for the specified element is supplied 
with the vessel.

 

The Model 

PRO-8-1000-MSP

 has been designed to meet the 

standards of the American Society of Mechanical Engineers 
(ASME), Boiler and Pressure Vessel Code, Section X. At an 
additional cost, vessels can be inspected during fabrication by an 
ASME Authorized Inspector and Code stamped. 

The Model 

PRO-8-1000-MSP

 must be installed, operated and 

maintained using good industrial practice and following the 
precautions listed in order to help assure safe operation and a 
long service life.  Misuse, improper installation or operation may 
result in severe bodily harm or property damage and will void the 
vessel warranty. Therefore, review and follow the safeguards 
listed below 

before

 placing the vessels into service. 

The filament-wound reinforced plastic shell of this vessel must 
be allowed to expand under pressure. Any undue restraint at the 
support points or piping connections can cause non-repairable 
leaks to develop in the shell. This vessel must not be subjected 
to excessive stress caused by bending moments acting at the 
side ports in the fiberglass shell. 

The end closures and side ports of the vessel must be kept dry 
and free of corrosion at all times.  Failure to do so may result in 
deterioration that can lead to catastrophic failure of the vessel 
heads.  

When requested, Bekaert Progressive Composites will assist the 
purchaser in determining the suitability of this standard vessel 
design for their operating environment. However, the final 
determination including the evaluation of the materials of 
construction for use in the specific corrosive environment shall 
be the responsibility of the purchaser. Alternate materials of 
construction may be available on special order.  

Before using this engineering packet for system design or vessel 
installation, please verify that it is the latest revision by consulting 
the factory. Specifications are subject to change without notice. 

PRECAUTIONS 

Follow all instructions

.  

Failure to take every precaution listed will void the vessel 
warranty and may result in vessel failure. 

Mount shell using furnished hardware. 

Following the recommended span(s), mount the vessel on 
saddles provided.  Tighten straps to one ft-lb maximum. 

Align the side ports with the manifold

.  

Center each vessel with the manifold and correct the causes 
of misalignment for each and every vessel. 

Use flexible type groove-end pipe couplings

.  

Use Victaulic™ style 77 or equal couplings at each side port 
and allow a gap between each port /manifold connection as 
specified by coupling manufacturer. 

Maximize the connection flexibility

.  

Position the vessel and the piping so that the vessel can grow 
in length and diameter under pressure without any undue 
restraint.  

DIA = 0.012 in. (0.3mm) and 

L = 0.25 in. (6mm) 

for a length code –7 vessel. 

Provide overpressure protection

.  

Set the safety device at not more than 105% design pressure. 

Inspect end closures and side ports regularly

.  

Replace damaged or deteriorated components and correct the 
cause of any corrosion. 

Relieve system pressure before working on the vessel

Working on vessels that are under pressure may result in 
bodily harm and/or property damage.

 

Never support other components with the vessel

.  

Hanging piping manifolds or supporting other components with 
the vessel may result in vessel damage. 

Do not over tighten the Permeate Port connection

.  

Tightening the connection more than one turn past hand tight 
will damage the port. 

Ensure that the Thrust Cone is installed downstream

.  

Operating without thrust cone may cause membrane damage. 

Double check end closure installation

 

Ensure that retaining ring is in place and fully seated. 

Never operate the vessel in excess of its ratings

This practice will void the vessel warranty, shorten vessel life 
and could lead to bodily harm or property damage. 

Do not operate the vessel permeate port over 125 psi

.  

Permeate pressure in excess of 125 psi must be approved by 
the factory prior to operation. 

Some components in the vessel are not compatible with 

hydrocarbons.  Contact factory for alternate material options. 

 

Flush the vessel before system shut down

.  

Some feed waters may cause corrosion under static 
conditions. Flushing with non-corrosive permeate is 
recommended. 

Operate the vessel within the recommended pH range

The vessel is designed for continuous use at a pH of 3-11 and 
for intermittent cleaning (less than 30 min. at a pH of 2-12). 

Do not install the vessel in direct sun light.

 

*Please inform the factory when continuous operating temperature is less than 45°F. 

Lenntech

[email protected]

www.lenntech.com

 

Tel. 

 

+31-15-261

.

09

.

00

Fax. +31-15-261

.62.89

 

 
 

Содержание PRO-8-1000-MSP

Страница 1: ...st revision by consulting the factory Specifications are subject to change without notice PRECAUTIONS Follow all instructions Failure to take every precaution listed will void the vessel warranty and...

Страница 2: ...in the bearing plate to pull the head out It is recommended that you contact the factory for head removal tools or instructions SIDE PORT SEAL REPLACEMENT While it is possible to replace the side port...

Страница 3: ...ith each vessel Allow one concentrate manifold to float In some systems the manifold can be connected to the vessels and supported by the floor but allowed to float in the axial direction to provide r...

Страница 4: ...Lenntech info lenntech com Tel 31 152 610 900 www lenntech com Fax 31 152 616 289...

Страница 5: ...rmation at the bottom of the ordering page for each vessel configuration 6 Sign and date the ordering page before you send it in NOTE Two ports per end maximum diametrically opposed Ports 1 and 5 are...

Страница 6: ...0 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 Flow Rate gpm Velocity ft s 3 pipe 2 5 pipe Calculated Pressure D...

Страница 7: ...Option NPT female threads Option Probing Port Option Probing Port Option Auto Shim feed end only FEED CONCENTRATE PORT CONFIGURATIONS Standard 3 IPS pipe grooved ends with ports in line 1K5K position...