Diagnostics and Troubleshooting
MVI46-S3964R
♦
SLC Platform
Siemens 3964R Protocol
ProSoft Technology, Inc.
Page 37 of 74
Press
[Esc]
to restart the module and force all drivers to be loaded. The module
will use the configuration stored in the module's Flash ROM to configure the
module.
4.1.4 Database
View
Menu
Press
[D]
from the Main Menu to open the Database View menu. Use this menu
command to view the current contents of the module's database. Press
[?]
to
view a list of commands available on this menu.
M = Main Menu
D = Database Menu
P = Previous Page
– = Back 5 Pages
0 – 3 = Pages 0 to 3000
F = Float Display
D = Decimal Display
H = Hexadecimal Display
N = Next Page
+ = Skip 5 Pages
A = ASCII Display
M = Main Menu
Goes up one level to main menu
Goes back one page of data
Goes back five pages of data
Selects page 0, 1000, 2000 or 3000
Displays data in decimal format
Goes forward one page of data
Goes forward five pages of data
Displays data in text format
Displays data in floating point format
Displays data in hex format
S = Show Again
Redisplays last selected page of data
? = Display Menu
Redisplays (refreshes) this menu
Viewing Register Pages
To view sets of register pages, use the keys described below:
Command Description
[0]
Display registers 0 to 99
[1]
Display registers 1000 to 1099
[2]
Display registers 2000 to 2099
And so on. The total number of register pages available to view depends on your
module's configuration.
April 17, 2008