ILX56-PBS
Setup
ControlLogix® Platform
User Manual
Page 16 of 87
Logix
The Logix configuration is shown in the following figure. The ILX56-PBS Logix configuration
window is opened by either double-clicking on the module in the tree, or right-clicking the
module and selecting
Configuration
.
Figure 3.8
– ILX56-PBS Logix configuration
The Logix configuration consists of the following parameters:
Parameter
Description
Logix Connections
The number of Logix (CIP) Connections (1 to 10) to be used in the exchange
with Logix.
Each backplane connection is configured with 500 bytes output and 496 byte
input and 0 byte configuration.
NOTE:
This value must match the same number of connections configured
in the Logix IO tree.
Controller Path
This is the CIP path to the Logix controller.
This path will be used for the Class 3 data exchanges for DPV1 objects and
alarms.
Response Timeout
The maximum time (ms) allowed for a Class 3 response from the Logix
controller.
Logix Base Tag A/B
This is the tagname of the ILX56-PBS used for the input and output assembly.
For example, if the module is in the local slot connected to a Logix controller
the base Logix tag will be local:x (where x is the slot number).
The base tagname is used when generating the Logix L5X file, which will
automatically map the required data.
NOTE:
Only Logix Base Tag A will be relevant.
Table 3.3 - Logix configuration parameters