3.5
Configuring a Radio - Getting Started
This section describes how to set up RLX2-IHx series radios in a minimal configuration
before deploying them in the permanent installation. See Configuring a Radio - Detailed
Configuration (page 52) for a detailed description of all the configuration parameters
available for your radio.
3.5.1 Connecting to the Radio Configuration Interface
This section describes how to connect to the RLX2
Radio Configuration / Diagnostic
web
interface using a web browser such as Internet Explorer or Firefox on your PC or other
network-enabled device.
To connect to the Radio Configuration / Diagnostic web interface
Important: Your computer or other device must be connected to the same network as the RLX2-IHx series
radio.
1
Log into the web interface of the radio. You can do this in any of three ways:
o
In the IH Browser List view or Topography view, right-click the radio and then
click
C
ONNECT
.
o
In the IH Browser List view or Topography view, double-click the radio.
o
Open a web browser on your PC, and then in the address bar, type
http://
,
followed by the IP address for the radio, and then press
E
NTER
. For example,
http://192.168.6.10
.
The login screen appears in the web browser.
2
Enter the password and then click
L
OGIN
. The default password is
password
. If you
have lost the password for the radio, you can reset the radio to its default settings.
See
Resetting a RLX2-IHx series Radio
(page 180).