5.6.3 Status
Group Register Content Description
Misc.
Status
6000
Program
Scan Count
This value is incremented each time a complete
program cycle occurs in the module.
6001,
6002
Product
Code
These two registers contain the product code of
"CAS"
6003,
6004
Product
Version
These two registers contain the product version for
the currently running software.
6005,
6006
Operating
System
These two registers contain the month and year
values for the program operating system.
6007,
6008
Run
Number
These two registers contain the run number value for
the currently running software.
6009
Port 1
Command
List
Requests
This field contains the number of requests made from
this port to slave devices on the network.
6010
Port 1
Command
List
Response
This field contains the number of slave response
messages received on the port.
6011
Port 1
Command
List Errors
This field contains the number of command errors
processed on the port. These errors could be due to a
bad response or command.
6012
Port 1
Requests
This field contains the total number of messages sent
out of the port.
6013
Port 1
Responses
This field contains the total number of messages
received on the port.
6014
Port 1
Errors Sent
This field contains the total number of error messages
sent out of the port.
6015
Port 1
Errors
Received
This field contains the total number of message errors
received on the port.
6016
Port 2
Command
List
Requests
This field contains the number of requests made from
this port to slave devices on the network.
6017
Port 2
Command
List
Response
This field contains the number of slave response
messages received on the port.
6018
Port 2
Command
List Errors
This field contains the number of command errors
processed on the port. These errors could be due to a
bad response or command.
6019
Port 2
Requests
This field contains the total number of messages sent
out the port.
6020
Port 2
Responses
This field contains the total number of messages
received on the port.
6021
Port 2
Errors Sent
This field contains the total number of message errors
sent out the port.