DPX Series 

Gas Control Panel  

User Manual 

DPX (4 / 8 32 / 64 / 128) 

 

 

 

 

Prosense Teknoloji San. Ltd. Şti.

 

Cumhuriyet Mah. Mermer sok. No:16 

34876 Kartal/İstanbul

 

Tel: (90) 216 306 77 88 Faks: (90)216 473 81 29 

www.prosense.com.tr

 

 

 

Содержание DPX 128

Страница 1: ...17 11 2021 PROSENSE DPX Series Gas Control Panel User Manual DPX 4 8 32 64 128 Prosense Teknoloji San Ltd ti Cumhuriyet Mah Mermer sok No 16 34876 Kartal stanbul Tel 90 216 306 77 88 Faks 90 216 473 8...

Страница 2: ...it could fail to perform as designed and persons who rely on this product for their safety could suffer severe personal injury or death The warranties made by Prosense with respect to this product ar...

Страница 3: ...ates 25 6 3 Warm up Status 25 6 4 Fault Status 26 6 5 Overrange Status 26 6 6 Alarm Status 27 7 Programming 28 7 1 Panel Configuration 29 7 1 1 Setting Up Network Parameters 29 7 1 2 Setting Up Passwo...

Страница 4: ...21 7 7 What to Do In Case Of Alarm 46 7 8 Failure Codes 47 8 Declaration 49 9 Appendix A Prosense Gas No Index 50 10 Warranty statement 52 10 1 Exclusions 52 10 2 Warranty Limitation and Exclusion 52...

Страница 5: ...med for Overrange can be optionally adjusted to alarm status Prosense DPX Series Panel is configured in 5 different configurations DPX4 4 x 4 20mA Analogue Channels DPX8 8 x 4 20mA Analogue Channels D...

Страница 6: ...ible Output Siren 24VDC 2A Network Output Ethernet RJ45 MODBUS over Ethernet optional MODBUS Output RS485 MODBUS RTU Output for external device communication Backup battery 2 x 12V 7A h Optional Opera...

Страница 7: ...anel Dimensions Panel dimensions are different for DPX4 and other models DPX4 panel dimensions are explained in Diagram 2 Diagram 2 Dimensions mm DPX8 DPX32 DPX64 DPX128 Panel dimensions are explained...

Страница 8: ...remove the panel door assembly Please take care and remove the connectors on the electronic card while removing the cover Fix the panel on to the wall via using 4 screw holes in each corner after rem...

Страница 9: ...ands to the holes you made it Make sure you are using an adequate IP66 rate cable gland to assure the box ingress protection is not compromised The panel box is modular and can be used with different...

Страница 10: ...c screw Diagram 7 Panel body Plastic screws Backup battery connectors and fuse Power supply N L G V V Wall mounting hole Wall mounting hole Main power entry and fuse Space for backup batteries Power s...

Страница 11: ...ain building blocks of the panel PCB are pointed with letters on picture Their meaning and details are as follows A MODBUS and Siren Outputs B Analogue Channel Inputs C Relay Outputs D MODBUS Channel...

Страница 12: ...ent in to fault or alarm status In case of alarm or fault user can disable this output temporarily via pressing the MENU button Panel waits five minutes and perform control again If there is still ala...

Страница 13: ...able Panel channels supply 24VDC power to detector and read the output signal of detector from S port Thus connections should be made correctly to do not cause any damage on the detectors Detector con...

Страница 14: ...ed 3 cores plus screen 90 coverage suitably mechanically protected copper cable with a suitable explosion proof gland or NPT steel conduit depending on the distance between signal received or control...

Страница 15: ...RELAY 1 This relay will be activated when any of the detectors in the system is in fault status ALARM1 RELAY 2 This relay will be activated when any of the detectors in the system will exceed the pro...

Страница 16: ...tor power on Line 1 RS485 B MODBUS Line 1 GND Ground for MODBUS connection A A Line for MODBUS communication B B Line for MODBUS communication VOUT B Power Output Line 2 V to supply detector power on...

Страница 17: ...put RS485 port A B input RS485 port B Table 9 Connection pin definitions The wiring for detectors utilized with RS485 board should be done by using connection cable EIA RS485 2 core wires with section...

Страница 18: ...ne Otherwise control panel may not communicate to all some or none of the detectors 5 5 Power Inputs DPX series Gas Control Panel has internal switching power supply The connections between switching...

Страница 19: ...L input Phase Gnd input Ground N input Neutral V output 24VDC Only for panel and detectors do not use for any other device V output VDC Table 10 Main power connection details 5 5 2 Backup Battery Conn...

Страница 20: ...has two input ports to connect analogue detectors and connects them as Modbus detector Module converts measurement signal coming from detectors to MODBUS data and performs MODBUS communication with t...

Страница 21: ...put port to detector V 24VDC RELAY OUT FAULT Fault relay output ALARM1 Alarm1 relay output ALARM1 Alarm2 relay output Table 12 Analogue Module connection descriptions Power input and detector output p...

Страница 22: ...on For Configuration Function For Display Operation MENU Enter to panel configuration menu Disable Buzzer and siren UP Go to upper menu option during configuration In normal operation scroll through t...

Страница 23: ...screen will be updated with fault summary screen in case of any fault The screen provides number of failures and their short summary Panel screen will be updated with alarm summary screen in case of...

Страница 24: ...cted to analogue input channel The example below shows Z1 CH1 meaning that detector is connected to analogue channel number 1 and assigned to Zone1 If detector is connected to Modbus channel it will b...

Страница 25: ...status AL2 will be reported for related detectors ALARM 2 LED will be lit on related zone Alarm 2 Relay RELAY 3 is energised Alarm 3 Alarm status AL3 will be reported for related detectors ALARM 3 LED...

Страница 26: ...state The FAULT Relay will be activated at same time Fault relay is normally energised and it will be de energised when any of the internal fault detection measures detects a fault The Fault LED will...

Страница 27: ...connected detector measurement reaches defined Alarm 1 threshold level Panel will show AL1 symbols for the related detector on display and also activate alarm LED on related zone Alarm 2 relay and LE...

Страница 28: ...ected detectors define zones adjust the alarm levels for each detector and adjust relay parameters Each detector should be defined independently to related detectors measurement unit and scale as well...

Страница 29: ...menu options 7 1 1 Setting Up Network Parameters DPX Series Gas Control Panel provides MODBUS and Ethernet connectivity Panel can directly connected to a device that can understand MODBUS communicatio...

Страница 30: ...y as L1 and L2 Level 1 L1 security password is used to enable menu access Level 2 L2 security password is used to enable detector configuration menu Select 2 Passwords option from Configuration menu t...

Страница 31: ...You can increase or decrease the value via using up and down keys Once desired value has been set press MENUbutton to confirm and move to the next digit to set Once all set press MENU button The displ...

Страница 32: ...on panel will continue operation in case power lost If panel is started while main power lost user must press the battery operation button to start battery 7 2 Detector Settings DPX Series Gas Control...

Страница 33: ...login To change password please see section Changing Passwords 3 Once the L2 password provided panel will display detector settings options Select 4 Analog Detector option 4 Analogue detector setting...

Страница 34: ...n parameters Channel No is pointing the analogue channel number that detector is connected DPX Series Gas Control Panel can have either 4 or 8 analogue channels DPX4 model have 4 channels while DPX8 h...

Страница 35: ...enu Panel program will display a table to set each alarm The cursor on Channle number will be blinking User must first set the number of channel that wanted to set the alarm and than select which alar...

Страница 36: ...ranges for each state are given in table XX State Default Minimum Maximum Fault 2 0mA 1 0mA 3 5mA Warm Up 3 0mA 1 0mA 3 5mA Calibration 3 0mA 1 0mA 3 5mA Inhibit 3 0mA 1 0mA 3 5mA Over Range 22 0mA 2...

Страница 37: ...as Control Panel can read detector configuration details through MODBUS communication from Prosense Gas Detectors To start communication between detector and panel detector must be set on through pane...

Страница 38: ...onnected to panel Zone No is the logical segment that user want to assign this detector If Zone No is set to zero 0 detector will be disabled even it is connected to panel 7 2 5 MODBUS Detector Alarm...

Страница 39: ...r MODBUS connected detectors will be same all the time 7 2 6 MODBUS Detector Calibration DPX Series Gas Control Panel can initiate calibration operation for detector connected to MODBUS channels This...

Страница 40: ...t status of the detector once the calibration operation completed User should always follow the instructions given in detector user manual as all related details are detector specific Panel is just pr...

Страница 41: ...ay settings select 2 Relay Settings from main menu Relay parameters will be listed on display for user to select relay number to change Program will also guide user to update each parameter For relay...

Страница 42: ...ns DPX Series Control Panel provides artificial testing option to user to control connections and event generation scenarios without using real gas To run tests select 4 Test option from main menu Pan...

Страница 43: ...energized or de energized 7 5 Information DPX Series Control Panel keeps event records To see recorded events select 5 Information option from main menu Panel program will display event groups for use...

Страница 44: ...on provides latest recorded event for detectors connected to MODBUS channels User should set first detector MODBUS address that desired to see event via using MENU and UP and DOWN keys Once address se...

Страница 45: ...ub menu Enter the menu and select 6 Reset option to execute reset operation Panel program will re scan all channels and detectors and update their current status It will display Successful message on...

Страница 46: ...control unit if it is in the same room If the gas concentration reading on the control unit does not fall below the level of alarm and the reason for the gas leak is not immediately apparent and or c...

Страница 47: ...GE ERROR Main power failure low or high 30 VOLTAGE OUT ERROR 31 CHNA VOLTAGE ERROR MODBUS RS485 A channel voltage failure 32 CHNB VOLTAGE ERROR MODBUS RS485 B channel voltage failure 33 CHNC VOLTAGE E...

Страница 48: ...interface level 19 NET_ERROR_SOCKET_FAILURE an error in interface level 20 NET_ERROR_OUT_OF_SOCKET no more available socket open failed 21 NET_ERROR_CLOSE_SOCKET error while closing socket 22 NET_ERR...

Страница 49: ...49 PRS UM DP X EN Rev1 0 17 11 2021 8 Declaration...

Страница 50: ...43 Iso propanol 44 Carbon monoxide 45 Acetone 46 Methylethylketon 47 Ethyl acetate 48 Ammonia 49 Ethylene 50 Acetic acid 51 Butyl acetate 52 Cyclo hexane 53 Cyclo pentane 54 Dioxane 55 Ethane 56 Buty...

Страница 51: ...JP8 74 Formaldehyde 75 HCN 76 Hydrogen peroxide 77 Nonane 78 Acetaldehyde 79 Hydrogen Chloride 80 TVOC 81 VOC 82 Ozone 83 HF 84 Phospine 85 Isobutylene 86 Silane 87 Diborane 88 Arsine 89 Germane 90 Ai...

Страница 52: ...uch inspection indicate that the gas sensor has been expended rather than failed prematurely this limited warranty shall not apply to the Product This limited warranty does not cover consumable items...

Отзывы: