MS-C005I Dust Blowing & Vacuum Cleaner
吹吸塵機
Specification
Power
450 W
Voltage
230V / 50Hz
No load speed
0-16000 rpm
Air Voltage
2.3m
3
/min
Accessories
1 x Air flow tube / 1x Dust bag
Dimensions
24 cm x 18 cm x 17 cm
Weight
1.4Kg
Important! – Safety instructions for all tools
Warning:
When using electric power tools, important safety
precautions must always be adhered to
in order to reduce the risk of
fire, electric shock and personal injury.
Safety Instruction
1.
Keep work area clean. Untidy benches and work areas cause
injuries.
2.
Consider work area environment. Do not use power tools in
damp or wet locations. Do not expose power tools to rain. Keep
work areas well lit.
3.
Guard against electric shock. Prevent body contact with
grounded surfaces. E.g. radiators, pipes, refrigerator enclosures
4.
Keep children away. All visitors must be kept away from the work
area. Do not let visitors come into contact with the tool or
extension cord.
5.
Store idle tools. When not in use, tools must be stored in a dry
place, out of reach of children.
6.
Dress properly. Do not wear loose clothing or jewelry, as these
can be caught in moving parts. Gloves and non-skid footwear are
recommended when working outdoors. Wear protective head
cover to contain long hair.
7.
Use safety glasses. Also use face and dust mask to guard against
dust.
8.
Do not abuse the cord. Never carry the tool by the cord or pull
the cord to disconnect the tool. Keep the cord away from heat, oil
or sharp objects.
9.
Do not overreach. Keep proper footing and balance at all times.
10.
Maintain tools with care. Keep tools clean for better and safer
performance. Follow instructions for lubricating and changing
accessories. Keep hands dry, clean and free from oil and grease.
11.
Disconnect tools. When not in use, before servicing and when
changing any accessories.
12.
Remove adjusting keys and wrenches. Have the habit to check
and see that keys and adjusting wrenches are removed from the
tool before turning on.
Operation Safety
1.
Don’t input voltage exceed the 230V± 5%
2.
Don’t operate blower if the unit broken crack or running with
abnormal sound, smell. Operate blower before running one
minute without any abnormal.
3.
Blower is running in high speed when operated, don’t insert any
thing into blower prevent fan or housing damage. Stop to use
when cause any abnormal sound.
4.
Move the item to out side before clean it use blower or open all of
windows, if item can’t be moved using vacuum clean function, to
prevent dust flying to every where.
5.
Stop to use in following situation, Insulation damage, cable
jacket damage cause power poor contact, strong spark and so
on.
6.
Clean the outlet and port after using for ensure the air in and out
smooth
Application
Suitable for clean computer CPU fan, power supply fan and chassis,
TV, monitor, speakers, etc.
。
Operation instructions
Assemble Nozzle to blower
When apply blower that assemble the nozzle to outlet,
When apply Vacuum Cleaner that assemble the nozzle to port and
assemble dust bag to outlet.
Align groove in outlet with projection on nozzle and slide the nozzle
onto the outlet.
Rotate the Nozzle to lock it into place, then tighten the clamp band.
Switch on/off
Pressing the switch button, the unit started. Loosing the switch
button is stopped. When lock button is pressed after unit is stared,
the unit can continually work and press the switch button again unit
can be stopped.
Maintenance
Always switch off and disconnect the plug from power source
before maintenance.
***Cleaning
Clean outside of blower by cloth dampened in soapy water. Never
clean by gasoline or any solution.
***Replace carbon brushes
Check the carbon brushes at regular intervals. It is must be
replaced with new brushes when it’s shorter than 6mm. Remove
brush covers and brushes by screwdriver, then insert new brushes
and screwing the cover. Please replace both brushes at same time.
Troubleshooting
Trouble
Reason
Troubleshooting
Switch on but
no running.
1.
Power plug
disconnect.
2.
Switch poor
connector.
3.
Armature or stator
coil damage.
4.
Coil wire is break.
1.
connect plug to
power source
2.
Replace power
switch
3.
Replace armature
or stator coil
4.
Solder the break
wire
Blower power
on with
abnormal
sound or not
running or
running
slowly.
1. Contactor of switch is
damaged.
2. Mechanical stuck
foreign body inside of
blower cause motor
over load
3. Armature shorted or
open
1. Replace switch
2. Check and clean
machine or
Armature
3. Repair or replace
armature
Housing
Surface
overheat
1. Motor wet
2. Assemble incorrect
3. Power low voltage
1. Dry the motor
2. Check and clean
machine or
Armature
3. Check power
voltage
Commutator
running with
fire or sparks
1. Armature shorted or
open
2. Commutator surface
not smooth or
unclean
1. Fix armature or
replace motor.
2. Clean commutator
or make the
surface smooth
Blowing Cleaner