Specification 

Power   

450 W 

Voltage 

230V / 50Hz 

No load speed 

0-16000 rpm 

Air Voltage 

2.3m

3

/min 

Accessories 

1 x Air flow tube    / 1x Dust bag 

Dimensions 

24 cm x 18 cm x 17 cm 

Weight 

1.4Kg 

Important! – Safety instructions for all tools 

Warning:

  When  using  electric  power  tools,  important  safety 

precautions must always be adhered to

 

in order to reduce the risk of 

fire, electric shock and personal injury. 

Safety Instruction 

1.

 

Keep work area clean. Untidy benches and work areas cause

 

injuries. 

2.

 

Consider work area environment. Do not use power tools in 

damp or wet locations. Do not expose power tools to rain. Keep 

work areas well lit. 

3.

 

Guard against electric shock. Prevent body contact with 

grounded surfaces. E.g. radiators, pipes, refrigerator enclosures 

4.

 

Keep children away. All visitors must be kept away from the work 

area. Do not let visitors come into contact with the tool or 

extension cord. 

5.

 

Store idle tools. When not in use, tools must be stored in a dry 

place, out of reach of children. 

6.

 

Dress properly. Do not wear loose clothing or jewelry, as these 

can be caught in moving parts. Gloves and non-skid footwear are 

recommended when working outdoors. Wear protective head 

cover to contain long hair. 

7.

 

Use safety glasses. Also use face and dust mask to guard against 

dust. 

8.

 

Do not abuse the cord. Never carry the tool by the cord or pull 

the cord to disconnect the tool. Keep the cord away from heat, oil 

or sharp objects. 

9.

 

Do not overreach. Keep proper footing and balance at all times. 

10.

 

Maintain tools with care. Keep tools clean for better and safer 

performance. Follow instructions for lubricating and changing 

accessories. Keep hands dry, clean and free from oil and grease. 

11.

 

Disconnect tools. When not in use, before servicing and when 

changing any accessories. 

12.

 

Remove adjusting keys and wrenches. Have the habit to check 

and see that keys and adjusting wrenches are removed from the 

tool before turning on. 

Operation Safety 

1. 

Don’t input voltage exceed the 230V± 5% 

2. 

Don’t  operate  blower  if  the  unit  broken  crack  or  running  with 

abnormal  sound,  smell.  Operate  blower  before  running  one 

minute without any abnormal. 

3. 

Blower is running in high speed when operated, don’t insert any 

thing into blower prevent fan or housing damage. Stop to use 

when cause any abnormal sound. 

4. 

Move the item to out side before clean it use blower or open all of 

windows, if item can’t be moved using vacuum clean function, to 

prevent dust flying to every where. 

5. 

Stop  to  use  in  following  situation,  Insulation  damage,  cable 

jacket damage cause power poor contact, strong spark and so 

on. 

6. 

Clean the outlet and port after using for ensure the air in and out

 

smooth 

Application 

Suitable for clean computer CPU fan, power supply fan and chassis, 

TV, monitor, speakers, etc.

 

Operation instructions 

Assemble Nozzle to blower 

When apply blower that assemble the nozzle to outlet, 

When apply Vacuum Cleaner that assemble the nozzle to port and 

assemble dust bag to outlet.   

Align groove in outlet with projection on nozzle and slide the nozzle 

onto the outlet.   

Rotate the Nozzle to lock it into place, then tighten the clamp band. 

 

 

 

 

 

 

 

 

 

 

 

 

 

               

     

 

Switch on/off

 

Pressing the switch button, the unit started. Loosing the switch 

button is stopped. When lock button is pressed after unit is stared, 

the unit can continually work and press the switch button again unit 

can be stopped. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance 

Always  switch  off  and  disconnect  the  plug  from  power  source 

before maintenance. 

***Cleaning   

Clean outside of blower by cloth dampened in soapy water. Never 

clean by gasoline or any solution. 

***Replace carbon brushes 

Check  the  carbon  brushes  at  regular  intervals.  It  is  must  be 

replaced with new brushes when it’s shorter than 6mm. Remove 

brush covers and brushes by screwdriver, then insert new brushes 

and screwing the cover. Please replace both brushes at same time. 

     

 

 

 

 

 

 
 

 

Troubleshooting 

Trouble 

Reason 

Troubleshooting 

Switch on but 
no running. 

1.

 

Power plug 
disconnect. 

2.

 

Switch poor 
connector.   

3.

 

Armature or stator 
coil damage. 

4.

 

Coil wire is break. 

1.

 

connect plug to 
power source 

2.

 

Replace power 
switch 

3.

 

Replace armature 
or stator coil 

4.

 

Solder the break 
wire 

Blower power 
on with 
abnormal 
sound or not 
running or 
running 
slowly. 

1. Contactor of switch is     

damaged. 

2. Mechanical stuck 

foreign body inside of 
blower cause motor 
over load 

3. Armature shorted or 

open   

1. Replace switch 
2. Check and clean 

machine or 
Armature 

3. Repair or replace     

armature 

Housing 
Surface 
overheat 

1. Motor wet 
2. Assemble incorrect 
3. Power low voltage 

1. Dry the motor 
2. Check and clean 

machine or 
Armature 

3. Check power 

voltage 

Commutator 
running with 
fire or sparks   

1. Armature shorted or 

open 

2. Commutator surface 

not smooth or 
unclean 

1. Fix armature or 

replace motor. 

2. Clean commutator 

or make the 
surface smooth 

Blowing Cleaner 

Vacuum Cleaner 

 

Отзывы: