background image

The symbol is used to indicate that some hazardous live terminals are 
involved within this apparatus, even under the normal operating conditions, 
which may be sufficient to constitute the risk of electric shock or  death.

The symbol is used in the service documentation to indicate that specific 
component shall be replaced only by the component specified in that 
documentation for safety reasons.

Protective grounding terminal

Alternating current/voltage

Hazardous live terminal

ON:

 Denotes the apparatus is turned on

OFF:

 Denotes the apparatus is turned off.

WARNING:

 Describes precautions that should be observed to prevent the danger 

                    of injury or death to the operator.

CAUTION:

 Describes precautions that should be observed to prevent danger of 

                   the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

·

Read these instructions.

·

Keep these instructions.

·

Heed all warning.

·

Follow all instructions.

Water & Moisture

·

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

IMPORTANT SAFETY SYMBOLS

The apparatus should be protected from moisture and 
rain, can not used near water, for example: near bath-
tub, kitchen sink or a swimming pool, etc.

·

Heat

The apparatus should be located away from the heat source such as radiators, 
stoves or other appliances that produce heat.

PMX Series Mixer

18

Physical

PMX1204FX

Dimensions (H x W x D)

251 x 324 x 89 mm
3.5 kg

weight (net)

PMX1404FX

Dimensions (H x W x D)

312 x 324 x 102 mm

5.5 kg

weight (net)

PMX1604FX

Dimensions (H x W x D)

365 x 324 x 102 mm

5.8 kg

weight (net)

PMX1804FX

Dimensions (H x W x D)

418 x 324 x 102 mm

6.4 kg

weight (net)

    Output Power

THD+N   +A

    2 x 100W
    2 x 300W
    2 x 300W

PMX1204FX
PMX1404FX
PMX1604FX
PMX1804FX

    2 x 300W

PMX1204FX
PMX1404FX
PMX1604FX
PMX1804FX

    0.5%
    0.1%
    0.1%
    0.1%

S/N   +A

PMX1204FX
PMX1404FX
PMX1604FX
PMX1804FX

> 80 dB

Frequency

    20Hz-20KHz (+0, -1dB)

Measuring conditions:

1:  1kHz rel.to 0 dBu; 20 Hz - 20 kHz, line input; main output; unity gain.

2:  20Hz - 20kHz; measured at main output. Channels 1 - 4 unity gain: EQ flat; all channels on main mix; 
     channels 1/3 as far left as possible, channels 2/4 as far right as possible. Reference = +6 dBu. 

> 80 dB
> 80 dB
> 80 dB

Содержание PMX-1804FX

Страница 1: ...rotect the environment in which we all live CE All specifications and appearances are subject to change without notice All information was correct at time of printing Musikhaus Kirstein GmbH does not guarantee for the accuracy or completeness of any description photograph or statement contained in this manual Printed colors and specifications may vary slightly from product Products from Musikhaus ...

Страница 2: ...OT OPEN IMPORTANT SAFETY SYMBOLS The apparatus should be protected from moisture and rain can not used near water for example near bath tub kitchen sink or a swimming pool etc Heat The apparatus should be located away from the heat source such as radiators stoves or other appliances that produce heat PMX Series Mixer 18 Physical PMX1204FX Dimensions H x W x D 251 x 324 x 89 mm 3 5 kg weight net PM...

Страница 3: ... any servicing other than those means described in the manual Refer all servicing to qualified service personnel only Only use accessories attachments or parts recommended by the manufacturer Warning Please remember the high sound pressure do not only temporarily damage your sense of hearing but can also cause permanent damage Be careful to select a suitable volume Objects do not fall into and liq...

Страница 4: ...e 12 2 4 3 AMP output 13 2 4 4 Heat removal system 13 5 SPECIFICATIONS 16 1 PMX Series Mixer 16 5 SPECIFICATIONS Mono inputs Microphone inputs XENYX Mic Preamp Type XLR electronically balanced discrete input circuit Mic E I N 20 Hz 20 kHz 0 Ω source resistance 50 Ω source resistance 150 Ω source resistance 134 dB 135 7 dB A weighted 131 dB 133 3 dB A weighted 129 dB 130 5 dB A weighted Frequency r...

Страница 5: ...rophone preamps including phantom power as an option Balanced line input and a powerful effects section The mixing consoles in the MX Series are optimally equipped for live and studio applications Owing to state of the art circuitry your MX console produces a warm analog sound that is unrivalled With the addition of the latest of both analog and digital technology digital technology these base in ...

Страница 6: ...nd connectors will be discussed in detail PMX Series Mixer 3 PMX Series Mixer 14 This also goes for mixing effects signals with the monitor mix The main difference is that the mix radio is adjusted using the FX TO MON control Of course a signal has to be fed into the ef fects processor via the FX control in the channel strip for both applications You can select the effect preset by turning the PRO...

Страница 7: ...pectively The mid band is configured as a peak filter with a centre frequency of 2 5kHz Fig 3 1 Digital effects module PROGRAM PUSH PHONES FX FOOTSW 2 4 BIT MULTI FX PROCESSOR 00 SMALL HALL 03 MID HALL 06 BIG HALL 09 CHURCH 10 SMALL ROOM 13 MID ROOM 16 BIG ROOM 19 CHAPEL 20 PLATE 27 SPRING 30 GATED REV 36 REVERSE 40 EARLY REFL 44 AMBIENCE 48 STADIUM 49 AMBIENCE FX 50 DELAY 59 ECHO 60 CHORUS 66 FLA...

Страница 8: ... routing controls L R PAN 1 MUTE ALT 3 4 1 dB 10 MUTE CLIP 0 10 15 20 25 30 40 60 8 SOLO PMX Series Mixer 12 Fig 2 14 Main mix outputs Alt 3 4 outputs and control room outputs 2 4 Rear view of PMX1204FX PMX1404FX PMX1604FX PMX1804FX 2 4 1 main mix outputs Alt 3 4 outputs and control room outputs MAIN OUTPUTS The MAIN outputs carry the MAIN MIX signal and are on balanced XLR connectors with a nomin...

Страница 9: ... left and the right channels when using separate equalizers 2 2 2 Equalizer stereo channels 2 2 4 routing switch solo and channel fader The function of the BAL ANCE control corresponds to the PAN control in the mono channels The balance control determines the relative proportion between the left and right input signals before both signals are routed to the main stereo mix bus The MUTE ALT 3 4 swit...

Страница 10: ...output link 2 TRACK TO MAIN POWER The blue POWER LED indicates that the device is switched on LEVEL METER The high procision level meter accurately displays the appropriate signal level 48V The red 48V LED lights when the phantom power supply is switch on The phantom power supply is necessary for condenser microphones and is activated using the switch on the rear of the device Please do not connec...

Страница 11: ...plifier of your monitor system to AUX SEND 1 The AUX SEND 1 master control determines the volume of the monitor mix PMX Series Mixer 9 You can now use the STEREO AUX RETURN MON control to adjust the level of the effects signal routed to the monitor mix The STEREO AUX RETURN 2 control determines the level of signals fed into the AUX RETURN 2 connectors which are routed to the main mix STEREO AUX RE...

Отзывы: