Cleaning protocol

Caution

Only the use of accessories planned and provided for this chair by Promotal 

is allowed.

Caution

This chair is not intended to be cleaned in a washing tunnel.

Only the use of accessories planned and provided for this chair by Promotal 

is allowed.

Under no circumstances shall Promotal be held liable under warranty for 

any damage caused by non-compliance with the use instructions for a 

detergentdisinfectant.

Warning

Any manipulation must only be carried out after 

reading the instructions manual in full. The 

equipment should only be used for its intended 

purpose as described in our documentation. 

Assembly must only be carried out by qualified 

personnel.

PROMOTAL shall not be held liable for any 

damage resulting from non-compliance with these 

instructions.

Cleaning/Disinfecting

Thischair must be regularly cleaned using the appropriate detergent products and disinfected using 
bactericidal, virucidal and fungicidal disinfectants.
A mild detergent such as soapy water can be used for routine cleaning of upholstery, stainless steel, aluminium 
or painted surfaces, plastic parts and control components, followed by effective rinsing and thorough drying. 
Detergents and disinfectants designed for use with medical appliances, such as those containing quaternary 
ammonium compounds, hydrogen peroxide, ethanol, chlorine compounds, etc. can be used on our medical 
devices provided that:

• The concentration prescribed by the suppliers of such products are complied with;
• The application conditions (contact time, quantity used, temperature, rinsing, etc.) are complied with;
• The supplier’s instructions state that the detergent-disinfectant used is suitable for use with:
 

• PVC, ABS, Polyamide, Polyurethane, Polypropylene

 

• Epoxy-coated metal surfaces

 

• Stainless steel or aluminium metallic surfaces.

Warning :

• Solvents are strictly prohibited.
• The use of abrasive powders or any other abrasive product should be avoided.
• High-pressure cleaning is forbidden.

Содержание 73

Страница 1: ...User s Guide Laboratory Chairs 73 76 83 86 Model Shown 83 ...

Страница 2: ... internet www promotal com The descriptions and specifications contained in this Operating Manual are deemed correct at the time of printing Promotal however reserves the right to modify its models and its procedures or render them obsolete without notice Before any order we recommend that our customers consult a local sales manager ...

Страница 3: ...7 Cleaning Disinfecting 7 User s Guide Laborator Chairs 8 Intended use 8 Features 8 Dimensions 8 Assembling instruction 10 Installing the base with castors or the base with levellers 11 Using the Stool 12 Adjusting the height 12 Adjusting with hand controle 12 Adjusting the backrest tilt 12 Adjusting the depth of the backrest 13 Adjusting the height of the backrest 13 ...

Страница 4: ...he footrest 14 Service life of the chair 15 Obligatory specific maintenance 15 End of the furniture s useful life 15 Note 16 Maintenance notebook 18 Warranty Information 19 Warranty 19 Obligations 19 Exclusions 19 Exclusive Remedy 19 No Authorization 19 ...

Страница 5: ...r General safety sign Refer to the instruction manual brochure Manuel d utilisation 5 Important Information Safety symbols Warning sign The information marked with this symbol must be read and strictly followed Note Procedure practice or condition Warning The warning pictograms and signs installed by the manufacturer must not be removed The manufacturer s responsibility is cancelled if these signa...

Страница 6: ...polystyrene cardboard packaging Storage condition The following conditions must be observed when storing any material The area must be clean well ventilated and be of a normal temperature Store products away from the elements and away from direct sunlight The area must not be damp The products must not be subject to bumps or jolts Do not store in an area where people are likely to pass Articles mu...

Страница 7: ...etergent products and disinfected using bactericidal virucidal and fungicidal disinfectants A mild detergent such as soapy water can be used for routine cleaning of upholstery stainless steel aluminium or painted surfaces plastic parts and control components followed by effective rinsing and thorough drying Detergents and disinfectants designed for use with medical appliances such as those contain...

Страница 8: ...appliance must not be installed in domestic premises Patient weight capacity Features Shaped seat in high density foam Adjustable articulated backrest in height and depth Base Ø 60 cm Dimensions Laboratory chairs Stools on base 73 76 H mini 47 cm 57 cm maxi 66 cm 82 cm Laboratory chairs Stools on castors 83 86 H mini 59 cm 60 cm maxi 69 cm 85 cm 8 User s Guide ...

Страница 9: ...80 460 520 92 H 30 55 360 420 440 ø 600 ø 50 15 360 420 120 15 ø 50 440 ø 600 80 60 120 80 460 520 H 475 400 ø 50 ø 600 55 30 92 80 400 H 475 400 ø 600 ø 50 80 60 120 80 400 H Model on base Model on castors ...

Страница 10: ...ion These chairs are not designed for use in an operating theatre The chairs are supplied dismounted The unit contains A seat A gaz column A backrest A 5 branch base with castors Or a 5 branch base with levellers 10 User s Guide ...

Страница 11: ...er s Guide 11 Installing the base with castors or the base with levellers 1Insert the column in the base 2Place the seat on the column 3Insert the backrest in the seat and tighten the screw 4Overall view ...

Страница 12: ...e To raise Activate the handle L upwards until the desired position is reached To lower Sit on the seat and activate the handle L downwards until the desired position is reached Adjusting the backrest tilt Using the screw VS1 adjust to the desired position 12 User s Guide ...

Страница 13: ...VS3 VS2 User s Guide 13 Adjusting the depth of the backrest Using the screw VS2 adjust to the desired position Adjusting the height of the backrest Using the screw VS3 adjust to the desired position ...

Страница 14: ...Accessories The footrest reference 927 Incompatible with the models 922 22 923 22 and 926 22 Installing the footrest 14 User s Guide ...

Страница 15: ... bolts Check that the gas column is functioning properly Check the condition of the casters Note this information and the date in the maintenance notebook End of the furniture s useful life Your dealer is responsible for reclaiming and processing this furniture at the end of its service life Do not hesitate to contact Promotal if necessary We will suggest to you a solution to process this equipmen...

Страница 16: ...16 User s Guide Note ...

Страница 17: ...User s Guide 17 ...

Страница 18: ... the retailer or manufacturer please clean and disinfect the material Product Reference Serial number cf label Manufacturing date start date of warranty Date Name of technician Type of intervention corrective action Maintenance notebook 18 User s Guide ...

Страница 19: ... surges floods natural catastrophes impacts etc or to the presence of foreign objects 7 Damage caused by improper hook up or by the power supply damage caused by corrosion or by gradual deterioration of the product 8 Indirect damage related to loss of use and penalties generated by poor performance 9 Aesthetic damage incurred by the outside parts of the equipment which does not hinder proper opera...

Страница 20: ...PROMOTAL FRANCE www promotal com DIC83_0718EN ...

Отзывы: