Running Redundancy Check (CLU)
Redundancy Check is a maintenance procedure for logical drives in fault-tolerant disk arrays that
ensures all the data matches exactly.
To run Redundancy Check:
1.
Main Menu
>>
Logical Drive Management
2. Highlight the logical drive you want and press
Enter
.
3. Highlight
Background Activities
>>
Start Redundancy Check
The redundancy check parameters appear.
•
Auto Fix
– Corrects inconsistencies automatically
•
Pause On Error
– Pauses the Redundancy Check when an error is found
To change a parameter, highlight it and press the backspace toggle between
Yes
and
No
.
4. Highlight
Start
and press
Enter
.
If necessary, you can pause and resume or stop and restart the Redundancy Check. You can
use the logical drive while Redundancy Check is running.
For Redundancy Check rate, see
“Making Background Activity Settings (CLU)” on page 152.
Locating a Logical Drive (CLU)
This feature helps you identify the physical drives assigned to the logical drive you are working with
in the CLU. To locate a logical drive:
1. Main Menu >> Logical Drive Management
2.
Highlight the logical drive you want and press Enter.
3.
Highlight Locate Logical Drive and press Enter.
The drive carrier status LEDs flash for one minute.
150
Vess A2000 Series NVR Storage Appliance
Promise Technologies
Содержание Vess A2600
Страница 277: ...3 Click the Driver tab to see the driver version 271 Product Manual Driver Installation and Update...
Страница 315: ...4 Select Custom and click Next 5 Click the Add Items button 309 Product Manual Windows System Recovery...
Страница 330: ...12 Click the Finish button 13 Click the Close button 324 Vess A2000 Series NVR Storage Appliance Promise Technologies...
Страница 363: ...Illustrated Connection Vess A2200 Illustrated Connection Vess A2600 357 Product Manual IO Terminal Board Information...