VessJBOD 1000 Series Quick Start Guide
12
Task 4: Making Data and Management Connections
You can configure your VessJBOD as:
•
JBOD Expansion to a VessRAID subsystem
•
Drive enclosures for a SuperTrak RAID controller
JBOD Expansion to a VessRAID Subsystem
Configuring a Data Path
To establish the data path:
1.
Connect the SAS HBA card in the Host PC to the SAS IN ports (with a circle
icon) on the VessRAID controller. See page 13, Figure 12.
2.
Connect the SAS Expansion port (with a diamond icon) of the VessRAID
controller to the SAS IN port (with a circle icon) on the I/O module of the first
VessJBOD.
3.
Connect the SAS OUT port (with a diamond icon) of the VessJBOD I/O
module of the first VessJBOD to the SAS IN port (with a circle icon) on the
I/O module of the second VessJBOD.
4.
Connect the remaining VessJBOD units in the same manner.
Be sure to connect circle icon to diamond icon and vice versa.
All SAS ports have SFF-8088 connectors.
Configuring a Management Path
VessRAID subsystems have one RAID controller. The controller has an Ethernet
(RJ45) Management Port connector that enables you to monitor the VessJBOD
subsystems over your network using the WebPAM PROe software.
To establish the management path:
1.
Connect the Management port on each VessRAID controller to your network
switch. See Figure 12.
2.
Connect the Host PC’s or Server’s NIC to your network switch.
Direct Management of VessJBOD
A management connection directly to the VessJBOD uses a serial connection to
the Host PC. See pages 16 and 19 for more information.
Содержание VessJBOD 1730
Страница 119: ...手順 1 VessJBOD の開梱 119 図 6 VessJBOD 1830 背面図 LED に関する説明は 130 ページを参照してください I O モジュール 電源装置 外付けファン ...
Страница 138: ...VessJBOD 1000 系列快速啟動指南 138 圖 6 VessJBOD 1830 後視圖 如需 LED 的說明 請參閱第 149 頁 I O 模組 電源供應器 熱抽換風扇 ...
Страница 156: ...VessJBOD 1000 系列快速入门指南 156 图 6 VessJBOD 1830 背面视图 有关 LED 指示灯的描述 请参阅第 167 页 输入 输出模块 电源设备 热交换风 ...
Страница 175: ...작업 1 VessJBOD 포장 풀기 175 그림 6 VessJBOD 1830 후면 모습 LEDs 에 대한 설명은 186 페이지를 참조하십시오 I O 모듈 전원 공급 장치 외부 팬 ...