Diaphragm Motor-Driven Dosing Pump

Sigma X Control Type - Sigma/ 1 S1Cb

Operating instructions

EN

Original operating instructions (2006/42/EC)

Part no. 982568

BA SI 078 07/18 EN

Please carefully read these operating instructions before use. · Do not discard.

The operator shall be liable for any damage caused by installation or operating errors.

The latest version of the operating instructions are available on our homepage.

Содержание Sigma 1 S1Cb

Страница 1: ...rating instructions 2006 42 EC Part no 982568 BA SI 078 07 18 EN Please carefully read these operating instructions before use Do not discard The operator shall be liable for any damage caused by inst...

Страница 2: ...to the cor rect operation of the device or is intended to make your work easier Safety notes Safety notes are identified by pictograms see Safety Chapter At the time of going to press these operating...

Страница 3: ...6 7 1 Installation hydraulic 26 7 1 1 Basic installation notes 30 7 2 Installation electrical 31 7 2 1 Control connectors 32 7 2 2 HMI operating unit 39 7 2 3 Pump power supply 40 7 2 4 Other units 41...

Страница 4: ...data 84 16 2 Viscosity 85 16 3 Shipping weight 85 16 4 Wetted materials 85 16 5 Ambient conditions 85 16 5 1 Ambient temperatures 85 16 5 2 Media temperatures 86 16 5 3 Air humidity 86 16 5 4 Degree...

Страница 5: ...ut bleed valve with valve springs 2 with bleed valve FPM without valve springs 3 with bleed valve FPM with valve springs 4 with relief valve FPM without valve springs 5 with relief valve FPM with valv...

Страница 6: ...ult indi cating pacing relay 24V 100mA Control version 0 Manual external contact with PulseControl timer 1 Manual external contact with PulseControl analogue 2 Manual external contact with PulseContro...

Страница 7: ...X Control Type Sigma 1 S1Cb DE German EN English ES Spanish FR French FPM fluorine rubber Pump without HMI control unit Standard with tube nozzle in the bypass Threaded connection on request Identity...

Страница 8: ...ftware setting Diaphragm rupture Error and if the operator takes appro priate safety measures n Only pumps with the design F Physiological safety with regard to wetted materials are approved for use w...

Страница 9: ...employment in the relevant field of work Electrical technician An electrical technician is able to complete work on electrical systems and recognise and avoid possible dangers independently based on...

Страница 10: ...ety data sheets are available and that they are kept up to date as well as for producing an associated hazard assessment for the workstations affected CAUTION Warning of feed chemical spraying around...

Страница 11: ...In exactly the same way plug all relays modules and options into the hood if available Only remove them when the operating instructions request you to do so In the event of an electrical accident dis...

Страница 12: ...rial damage The device can be damaged by incorrect or improper storage or transportation The unit should only be stored or transported in a well packaged state preferably in its original pack aging Th...

Страница 13: ...trol unit 2 Frequency converter 3 Drive unit 4 Stroke length adjustment wheel 5 Drive motor 6 Liquid end 7 Diaphragm rupture sensor 1 2 P_SI_0088_SW_2 Fig 3 Sigma control elements 1 Bleed valve option...

Страница 14: ...luetooth active display blue 8 Fault indicator red 9 Warning indicator yellow 10 Operating indicator green P_SI_0193_SW 6 7 5 4 3 2 1 8 Fig 5 Connector cover control elements 1 Relay and mA output opt...

Страница 15: ...tion and adjustment of the pump by providing different information and identifiers 120 120 12000 Dosing monitor CONTACT memory l h CAN open h h 12000 ANALOGUE h h Input signal 4 mA Input signal 4 mA i...

Страница 16: ...pump is in ANALOGUE operating mode The Curve linear type of processing is set The pump is in ANALOGUE operating mode The Curve Upper side band type of processing is set AUX The pump is currently pump...

Страница 17: ...Move back to a continuous display Priming press Priming Priming Clickwheel press Start batch only in Batch operating mode Acknowledge errors Move to next menu option or a continuous display Confirm en...

Страница 18: ...d Every metering profile is ineffective below the switch over frequency for Start Stop mode Normal 0 s s a 180 360 0 b 180 360 P_PL_0009_SW Fig 8 Stroke movement at a maximum stroke length and b reduc...

Страница 19: ...ough the suction valve 1 into the dosing head One cycle is thus completed 4 2 1 5 3 13 Fig 9 Cross section through the liquid end 1 Suction valve 2 Diaphragm 3 Discharge valve 4 Dosing head 5 Backplat...

Страница 20: ...hragm With the visual diaphragm rupture sensor the lowered red cylinder 6 springs forward beneath the transparent cover 7 so that it then becomes clearly visible Fig 11 With the electrical diaphragm r...

Страница 21: ...ol type SxCb pumps with Can connector or Supplementary instructions for delta DLTa and Sigma SxCb with PROFIBUS 5 6 Functions The following functions can be selected using the Settings menu Calibrate...

Страница 22: ...r tripped level switches the fault indicating relay connects to complete an electric circuit for control panel etc In addition to the fault indicating relay the pacing relay can be used to make a cont...

Страница 23: ...ormal bus mode green flashing Bus status PRE OPERA TIONAL currently no measured value com munication wait briefly Disconnect HMI then reconnect red any Bus error no meas ured value transmission Check...

Страница 24: ...tained pumps Danger can arise from a poorly accessible pump due to incorrect operation and poor maintenance Ensure that the pump is accessible at all times Adhere to the maintenance intervals Positio...

Страница 25: ...ered with the wall mounting the HMI can be mounted directly on a wall Install the HMI in the immediate vicinity of the pump If not provided for fit a circuit breaker there refer to the Installation el...

Страница 26: ...ppropriate safety pre cautions WARNING Warning of feed chemical reactions to water Feed chemicals that should not come into contact with water may react to residual water in the liquid end that may or...

Страница 27: ...f the system CAUTION Warning against rupturing of suction or discharge lines Hose lines with insufficient pressure rating may rupture Only use hose lines with the required pressure rating CAUTION Unco...

Страница 28: ...liquid end do not represent absolutely leak tight closing elements Use a shut off valve a solenoid valve or a vacuum breaker for this purpose CAUTION To check the pressure conditions in the piping sy...

Страница 29: ...legal positive pressure using other mechanisms CAUTION Warning of feed chemical spraying around If no overflow line is connected to the integral relief valve or the integral bleeder valve feed chemica...

Страница 30: ...Screw the enclosed diaphragm rupture sensor into the liquid end CAUTION Warning of unnoticed diaphragm rupture Only above approximately 2 bar system back pressure is a signal generated in the event o...

Страница 31: ...A standard installation B with pulsation damper 1 Main line 2 Storage tank Symbol Explanation Symbol Explanation Metering pump Foot valve with filter meshes Injection valve Level switch Multifunctiona...

Страница 32: ...fect If the universal control wire the external pacing cable or the level monitoring cable is shortened below 1 20 m the pump does not detect that it is connected Conse quently a warning message for e...

Страница 33: ...be reprogrammed in the Relay menu The relay can be retrofitted and is operational once it has been plugged into the relay board Data Value Unit Maximum contact load at 230 V and 50 60 Hz 8 A resis tiv...

Страница 34: ...100 mA Minimum mechanical service life 200 000 switching operations Data Value Unit Residual voltage max at Ioff max 1 A 0 4 V Maximum current 100 mA Maximum voltage 24 VDC Closing time 100 ms Pin ass...

Страница 35: ...rent range 4 20 mA Ripple max 80 A ss Load max 250 Data Value Unit Residual voltage max at Ioff max 1 A 0 4 V Maximum current 100 mA Maximum voltage 24 VDC Closing time 100 ms To pin VDE cable Contact...

Страница 36: ...activation 1 brown Pause 2 white Contact 4 black GND 3 blue Analog 5 grey Auxiliary External activation 1 brown Pause 2 white Contact 4 black GND 3 blue Analog 5 grey Auxiliary External activation GND...

Страница 37: ...approx 5 V Input resistance 10 k Control n Potential free contact approx 0 5 mA n Semiconductor switch residual voltage 0 7 V min contact duration 20 ms Max pulse frequency 25 pulses s 3 Analogue inp...

Страница 38: ...3 white NO pacing relay Fault indicating and Pacing relay VDE cable Empty signal 2 brown C pacing relay 1 white NO 4 brown C 1 yellow NO fault alert 4 green C fault alert 2 green NC fault alert 3 bro...

Страница 39: ...Auxiliary External activation 1 brown Pause 2 white Contact 4 black GND 3 blue Analog 5 grey Auxiliary External activation GND GND Function External Contact ProMinent universal control wire 5 core Pa...

Страница 40: ...to a proper grounding type recep tacle WARNING Danger of electric shock In the event of an electrical accident it must be possible to quickly disconnect the pump and any electrical ancil laries which...

Страница 41: ...the pump to a zero volts state independently from the entire installation e g for repair use an electrical isolating device in the mains supply cable e g a mains switch or a plug socket combina tion C...

Страница 42: ...Makro operating mode Information Menu German English Language Language German Menu Information Path derived Language Language English German Save Menu Information Path operating instructions Language...

Страница 43: ...hanging from one figure to its initial figures b Changing the figure c Returning from the last figure to the complete figure to correct a wrong figure for example Changing a complete number Turn the C...

Страница 44: ...a continuous display shows different information which cannot be adjusted in the secondary display see Continuous displays and secondary displays overview in the appendix You can access secondary dis...

Страница 45: ...Menu is sub divided as follows 1 Information 2 Operating mode 3 Settings 4 Timer 5 Service 6 Language 9 1 Information Menu Information You can find out different information about your pump in the In...

Страница 46: ...f strokes figures 1 to 99 999 You can trigger the strokes using the Clickwheel if you have already switched to the Push continuous display You can also trigger them via a pulse using the External cont...

Страница 47: ...ted the pump adds up the remaining strokes which could not be processed up to the maximum capacity of the stroke memory of 99 999 strokes If this maximum capacity is exceeded the pump goes into fault...

Страница 48: ...executed per 1 pulse With a factor of 0 5 1 stroke is executed after 2 pulses With a factor of 0 1 1 stroke is executed after 10 pulses With a factor of 0 75 1 stroke is executed once after 2 pulses t...

Страница 49: ...The symbol Linear curve appears on the LCD screen You can enter any pump stroke rate behaviour proportional to the current signal You can enter the curve points I and F in the Curve points menu You d...

Страница 50: ...ve You can enter the curve points I and F in the Curve points menu Everything functions according to the Lower side band type of the pro cessing Curve points To define the above curves enter any two p...

Страница 51: ...e stage With Metering Pressure stage you can reduce the nominal pressure of the pump via the pressure stages refer to the Functional description chapter When selecting a pressure stage you are simulta...

Страница 52: ...ming if the suction hose is empty 1 Record the level in the measuring cylinder 2 Select the Menu Information Settings Calibrate menu and press the Clickwheel The Start calibration PUSH menu item appea...

Страница 53: ...activated via the External control terminal If the Auxiliary frequency is present then the identifier AUX appears on the LCD screen Refer to the Hierarchy of Operating Modes Functions and Fault Status...

Страница 54: ...closed in normal mode and opens with a triggering event normally open NO The relay is open in normal mode and opens with a triggering event 9 3 4 3 Relay2 optional Menu Information Settings Inputs ou...

Страница 55: ...iliary frequency Under Signalling you can set whether the control is to trigger an error or a warning when the tolerance is exceeded 9 3 4 6 Diaphragm rupture Menu Information Settings Inputs outputs...

Страница 56: ...s also set to its own hemisphere of the world 9 3 7 Date Menu Information Settings Date You can set the date in the Date menu 9 4 Timer Menu Information Timer The process timer can do the following to...

Страница 57: ...nds entered n Change only if commands entered n Clear only if commands entered n New Use New to create a new command 9 4 2 2 Init Initial conditions Use Init to specify initial conditions at the start...

Страница 58: ...ction Value Manual Strokes h Stop Frequency Strokes h Contact Batch input Batch time hh mm 9 4 2 5 Checking the finished command The pump displays the finished command program line as soon as you have...

Страница 59: ...10 40 Stop Stop Explanation At a capacity of 12 l h the pump has to work for 10 minutes to meter 2 litres Example of Weekday metering 9 5 Service Menu Information Service 9 5 1 Password Menu Informati...

Страница 60: ...n page 78 Tab 8 Input information Line Information 1 Line number 2 Date time 3 Type of entry fault warning 4 Input number 5 Explanation of the input 9 5 4 Display Menu Information Service Display You...

Страница 61: ...ation Service Spare parts kit part number XXXXXXX You can read off the part number order number of the correct spare parts kit here 9 6 Language Menu Information Language You can select the desired op...

Страница 62: ...sonnel The operator is responsible for ensuring that under the given operating conditions pressure tempera ture corrosiveness etc danger to the operating per sonnel is avoided by use of appropriate ac...

Страница 63: ...phragm rupture sensor with back pressures of greater than 2 bar Or install a back pressure valve and set it to a min imum of 2 bar if the installation permits this The valves may no longer close prope...

Страница 64: ...ted When operating the integral relief valve close to the opening pressure a minimal overflow into the overflow line can occur Only adjust the stroke length when the pump is running This is easier and...

Страница 65: ...p Press STOP START again Press Priming In Batch operating mode Turn the Clickwheel in a continuous display until the Push continuous display appears and then press the Clickwheel Press the Clickwheel...

Страница 66: ...tting mode Continuous display Stop start pump Priming Start batch only in Batch mode Acknowledge errors Check adjustable variables 2 Change directly adjustable variables B1059 Fig 35 Control options u...

Страница 67: ...unauthorised persons Depressurise the system before commencing any work on hydraulic parts WARNING Warning of hazardous feed chemical Should a dangerous feed chemical be used it may escape from the h...

Страница 68: ...that the electrical connections are intact Technical personnel Under normal loading approx 30 of continuous operation Under heavy loading e g continuous operation aggressive feed chemi cals etc short...

Страница 69: ...e switched on again by unauthorised persons Depressurise the system before commencing any work on hydraulic parts WARNING Warning of hazardous feed chemical Should a dangerous feed chemical be used it...

Страница 70: ...use new components which fit your valve both in terms of shape and chemical resistance Note the flow direction of the discharge and suction connectors when fitting the valve CAUTION Warning of feed c...

Страница 71: ...he stop at 0 stroke length The drive axle is now difficult to turn 3 Switch off the pump 4 Unscrew the hydraulic connectors on the discharge and suction side 5 Unscrew the diaphragm rupture sensor fro...

Страница 72: ...N Warning of escaping feed chemical The liquid end may leak should it not be possible to check the tightening torque of the screws Check the tightening torque of the screws after 24 hours of operation...

Страница 73: ...s the red cylinder into the diaphragm rupture sensor again and repeat the test 5 If it does not trigger both times replace the membrane rupture sensor 6 After a successful test screw the transparent c...

Страница 74: ...section through the liquid end 1 Suction valve 2 Diaphragm 3 Discharge valve 4 Dosing head 5 Backplate 13 Safety diaphragm Data Value Unit Tightening torques for dosing head screws 4 5 5 0 Nm Tighten...

Страница 75: ...working on the pump material failure or incorrect handling of the pump Take appropriate protective measures before working on the pump e g safety glasses safety gloves Adhere to the material safety d...

Страница 76: ...w 2nd stage Top up the storage tank Technical personnel The External MEM symbol appears flashing on the LCD screen plus the Memory overflow 34 error message and the pump stops The stroke tank has over...

Страница 77: ...t off valve or clear the constriction then Press P OK think through the consequences for the process Technical personnel 14 3 Warning messages Yellow LED Warning indicator display lights up Fault desc...

Страница 78: ...hink through the consequences for the process Technical per sonnel The temperature is too high Rectify the cause then Press P OK think through the consequences for the process Technical per sonnel The...

Страница 79: ...length has been modified beyond the tolerance limit with the pump locked 40 Different version statuses of the CTRL PFC and FC communication software 41 The HMI version is not compatible 42 System EEPR...

Страница 80: ...n in the event of overpressure fast Missing data stored in the CTRL in the HMI The data coming from the CTRL is faulty 14 5 3 Events in the log book Message no Description 4 The stroke length was adju...

Страница 81: ...mical residues There is normally chemical residue in the liquid end and on the housing after operation This chemical residue could be hazardous to people It is mandatory that the safety note relating...

Страница 82: ...torage and transport Take into account the information in the Storage Transport and Unpacking chapter if the system is decommissioned for a temporary period 1 Disconnect the pump from the mains power...

Страница 83: ...is device features the symbol showing a waste bin with a line through it The device must not be disposed of along with domestic waste To return the device use the return and collection systems availab...

Страница 84: ...022 SST 10 145 27 7 90 5 0 6 1 3 4 10 10044 PVT 10 145 53 14 170 5 1 6 1 3 4 10 10044 SST 10 145 53 14 170 5 1 6 1 3 4 10 07065 PVT 7 102 63 16 200 5 2 6 1 3 4 10 07065 SST 7 102 63 16 200 5 2 6 1 3 4...

Страница 85: ...07065 PVT 9 8 SST 11 7 07042 04084 04120 PVT 10 0 SST 13 2 16 4 Wetted materials Material ver sion Liquid end Suction pres sure connector Seals ball seat Balls Springs Integral relief valve PVT PVDF...

Страница 86: ...nts Protection against contact and humidity IP 65 in accordance with IEC 529 EN 60529 DIN VDE 0470 Part 1 A CAN plug or the supplied sealing cap must always be plugged into the CAN port for the HMI De...

Страница 87: ...fective current 1 5 A Switch on peak current for approx 100 ms 4 A Electrical data at 230 VAC Data Value Unit Effective current 0 6 A Switch on peak current for approx 100 ms 8 A Tab 11 Fuses Fuse Val...

Страница 88: ...ve surface uncovered 3 mA Power consumption active surface cov ered 1 mA Rated switching distance 1 5 mm Ri 1 k Cable colour Polarity blue brown 16 9 Relay The technical data for the relay are contain...

Страница 89: ...ings Compare the dimensions on the dimension sheet and pump All dimensions are in mm HMI and wall bracket 2 105 1 105 1 72 5 156 7 160 121 48 21 5 6 5 4 5 4 5 P_SI_0192_SW Fig 40 Dimensions in mm Dime...

Страница 90: ...12017 12035 10050 SST DN 10 231 89 G1 3 4 M 92 108 88 108 100 45 10022 10044 07065 PVT DN 10 234 87 G1 3 4 M 93 112 109 84 96 131 62 10022 10044 07065 SST DN 10 231 89 G1 3 4 M 92 108 88 108 100 45 07...

Страница 91: ...88 108 100 45 10022 10044 07065 PVT DN 10 234 87 G1 3 4 M 63 82 79 84 96 131 62 10022 10044 07065 SST DN 10 231 89 G1 3 4 M 62 78 88 108 100 45 07042 04084 04120 SST DN 15 243 78 G1 M 68 99 89 74 122...

Страница 92: ...P_SI_0185_SW Fig 43 Representation is not strictly binding dimensions in mm Dimensional drawings 92...

Страница 93: ...tur ambient temperature temp rature ambiante temperatura ambiente Ex Schutzklasse Schaltung ex protective system connection class de protection Ex branchement clase de protecci n Ex conexi n Drehzahlr...

Страница 94: ...ription 1 Spring 2 Ball 3 Ball seat 4 Diaphragm rupture sensor optical 5 Valve 6 Multi layer diaphragm The items listed are included in the spare parts kit Special accessories not included in the spar...

Страница 95: ...23 1033323 Valve 1002267 1002267 1002267 Multi layer diaphragm 1030114 1030114 1030114 Tab 15 Order no for liquid end for Sigma 1 065 DN 10 PVT Spare part 10022 10044 07065 Liquid end 1030105 1030105...

Страница 96: ...iaphragm The items listed are included in the spare parts kit Special accessories not included in the spare parts kit Technical changes reserved Tab 16 Order no for liquid end for Sigma 1 120 DN 15 PV...

Страница 97: ...egrated bleed valve complete DN10 PVE 1041068 The items listed are included in the spare parts kit Springs made from Hastelloy C O rings from FPM A and EPDM Technical changes reserved P_SI_0086_SW 10...

Страница 98: ...042 Type 04084 04120 10 Relief valve complete 7 bar PVA 740811 10 Relief valve complete 4 bar PVA 740812 The items listed are included in the spare parts kit Springs made from Hastelloy C O rings from...

Страница 99: ...diaphragm The items listed are included in the spare parts kit Special accessories not included in the spare parts kit Technical changes reserved Tab 17 Order no for liquid end for Sigma 1 50 DN 10 S...

Страница 100: ...0114 1030114 1030114 Tab 18 Order no for liquid end for Sigma 1 65 DN 10 SST Spare part 10022 10044 07065 Liquid end 1030107 1030107 1030107 Spare parts kit 1035966 1035966 1035966 Spare parts kit wit...

Страница 101: ...diaphragm The items listed are included in the spare parts kit Special accessories not included in the spare parts kit Technical changes reserved Tab 19 Order no for liquid end for Sigma 1 120 DN 15 S...

Страница 102: ...13 10 Fig 50 Sigma 1 SST bleed valve Pos Description Order no 10 Integrated bleed valve complete DN10 SSA 1041071 10 Integrated bleed valve complete DN10 SSE 1041072 The items listed are included in t...

Страница 103: ...12 bar SSA 1005625 10 Relief valve complete 10 bar SSA 1018573 10 Relief valve complete 7 bar SSA 740815 10 Relief valve complete 4 bar SSA 740814 The items listed are included in the spare parts kit...

Страница 104: ...ion 1 x diaphragm 2 x valve balls 2 x cover rings 4 x composite seals 1x sealing washer for bleed valve or relief valve Tab 22 Spare parts kits PVT liquid ends Liquid end Types 12017 12035 10050 Types...

Страница 105: ...amic PVDF EPDM SST Stainless steel 1 4404 Stainless steel 1 4581 PTFE PVDF Stainless steel 1 4404 Stainless steel EPDM Metering diaphragm is PTFE coated seals are PTFE composite seals PTFE FDA No 21 C...

Страница 106: ...120 0 140 0 20 0 40 0 60 0 80 0 100 0 120 0 140 0 160 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 04120 04084 07042 0 0 160 0 04120 04084 07042 12 0 p bar S C l h C l h A B 0 10 20 30 40 50 60 70 80 90 100 0 0...

Страница 107: ...duct not approved by us will invalidate this dec laration Tab 24 Excerpt from the Declaration of Conformity Designation of the product Metering pump Sigma product range Product type S1Cb Serial number...

Страница 108: ...isplay Stop start pump Priming Start batch only in Batch operating mode Acknowledge errors Check adjustable variables Change directly adjustable variables Settings Batch Contact Analogue Metering Cali...

Страница 109: ...ng mode Manual Contact Memory On Off Factor Batch Memory On Off Factor Analogue Standard 0 20 mA 4 20 mA Extended Curve Curve points Error message I 4 mA Metering Metering profile Standard Metering op...

Страница 110: ...rate Pump inactive Relay 2 polarity normally open NO normally closed NC mA output Range 0 20 mA 4 20 mA Function Strokes minute Capacity Capacity at 20 mA Flow monitor Activation Off On Tolerance str...

Страница 111: ...ivation Active Inactive Setting the timer Displays Change Clear New Command 01 Anweisung2 Hourly Daily Mon Sun Weekdays1 Mo Fr Weekdays2 Mo Sa Weekend Sa Su Weekly Monthly Init Clear all No Yes Servic...

Страница 112: ...gm part number XXXXXXX Spare parts kit part number XXXXXXX Language English German French Spanish Italian Menus may be missing or added depending on the design and equipment on the pump Operating menu...

Страница 113: ...factor 5 mode Batch with transfer factor 5 mode Analogue Analogue Stroke rate h Stroke rate min Capacity Trigger batch Factor Contact volume Time 7200 h 120 min 350 l h 17 12 21 17 12 21 5 1 250 L 720...

Страница 114: ...city Factor Stroke length Signal current at the input Dosing mode Time Total number of strokes Remaining litres Date Remaining strokes 1 only with Storage tank function extension 2 only with current o...

Страница 115: ...lves 69 Clear 57 Clear all 58 Clear counter 59 Clear all 58 Clearing the program 58 Climate 86 Code 59 Connector size 84 Contact 21 23 46 87 Contact memory 59 Continuous display 15 Continuous displays...

Страница 116: ...puts outputs 53 Installation 26 Installation height 86 Integral bleeder valve 29 Integral relief valve 29 Intended use 8 IP 86 K Keys 13 17 L Language 61 Leakage hole 68 LED 13 LED displays 23 Level s...

Страница 117: ...Requirements 86 Scope of delivery 12 Secondary display 15 Secondary displays 44 114 Semiconductor relay 22 34 35 Serial number 45 107 Service 59 Set time 56 Set up chapter 45 Set up overview 108 Sett...

Страница 118: ...51 85 Volume counter 59 Volume unit 56 W Wall bracket 89 Warning 54 Warning indicator 13 23 Warning messages 15 Warning messages log book 78 Warning sign 8 Wear parts 104 Weight 85 Wetted materials 85...

Страница 119: ...119...

Страница 120: ...982568 2 en_GB 2018 ProMinent GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany Telephone 49 6221 842 0 Fax 49 6221 842 419 Email info prominent com Internet www prominent com...

Отзывы: