Protective equipment
May only be removed by*:
Motor terminal box cover
Electrical technician, ATEX elec‐
trical technician, Service
Protective cowling over the motor
fan
Service
Power end front cover
Service
* Only if required by the operating instructions and if the mains cable
remains disconnected from the mains voltage.
The operator must be able to:
n
Perform a risk assessment
n
Produce and attach a nameplate
n
Issue a Declaration of Conformity
n
Adapt the operating instructions, if necessary
n
Install the motor correctly
1.
Select a suitable motor - it must correspond to the data for one of
the motors from the "Motor data" table - see Chapter "Technical
data"
2.
Fit the motor correctly on the flange (qualified personnel).
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, create a Declaration of Conformity, fit a company name‐
plate, ... .
4.
Complete the pump documentation / operating instructions.
Sound pressure level LpA < 70 dB according to EN ISO 20361
at maximum stroke length, maximum stroke rate, maximum back pressure
(water)
2.1 Safety information for ATEX designs
This chapter lists all safety information for ATEX designs. Safety informa‐
tion is listed again at the relevant points in these operating instructions.
This safety information is supplementary to or replaces the safety informa‐
tion for non-ATEX designs. If the safety information for ATEX designs con‐
tradicts the other safety information, then the safety information in this
chapter applies to ATEX designs.
n
Only operate the pump in premises at risk from explosion in an ATEX
designs in accordance with the applicable guidelines.
n
Do not expose the ATEX design to any sources of ionising radiation or
electromagnetic high frequency radiation in the range 10
4
... 3x10
15
Hz
or ultrasound or lightning without putting in place measures in line with
EN 1127-1.
n
The ATEX design may not meter media, which tend to produce exo‐
thermic reactions or self-ignite (examples of exothermic reactions:
pyrophoric substances with air, alkali metal with water, decomposition
of organic peroxides, polymerisation reactions), without taking effec‐
tive measures in accordance with EN 1127-1.
Requirements if the motor is being
installed independently
Install the motor - with designs without
motor
Sound pressure level
Intended use
Safety chapter
11