About limit values
B0231
calibration
stroke feedback
volume (stroke)
0.347 mL
stroke feedback
set-point
P
P
P
P
volume (stroke)
0.347 mL
tolerance
tolerance (%)
P
lower limit
0.312 mL
tolerance
limits
P
P
P
upper limit
0.416 mL
Alternatively, the required limits for the permitted range of the stroke volume can be entered under
‘lower limit’ and ‘upper limit’ :
1.
Follow the
‘calibration
è
stroke feedback
è
setpoint’ menu path and press [P].
ð
The
‘volume (stroke)’ menu item displays the setpoint currently saved.
2.
Start the metering pump.
ð
The current measured value is displayed.
3.
Turn the stroke length adjustment knob until the required setpoint is displayed.
4.
Press
[P].
ð
The measured value displayed is saved as a setpoint and the
‘tolerance tolerances’
menu item appears.
The setpoint is valid as 100 %.
5.
Use the
[arrow keys] to move to the ‘tolerance limits’ menu item and press [P].
6.
Turn down the stroke length adjustment dial until the required lower limit is reached and
press
[P].
7.
Proceed in the same way for the upper limit.
ð
The continuous display appears again.
8.
Stop the metering pump.
Set up
44