Check the operating instructions in order to ensure that the
flow values, pressures and power consumption of the motor do
not exceed the rated values
n
Install a pressure relief valve in the pressure line in order to
protect the pump in the event that a valve is unintentionally
closed off or the line is blocked in another way.
4.3.6.2 Filling level for pump housing
WARNING!
Danger from hazardous substances!
Possible consequence: Fatal or very serious inju‐
ries.
Please ensure when handling hazardous sub‐
stances that you have read the latest safety data
sheets provided by the manufacture of the haz‐
ardous substance. The actions required are
described in the safety data sheet. Check the
safety data sheet regularly and replace, if neces‐
sary, as the hazard potential of a substance can be
re-evaluated at any time based on new findings.
The system operator is responsible for ensuring
that these safety data sheets are available and that
they are kept up to date, as well as for producing
an associated hazard assessment for the worksta‐
tions affected.
Check the lubricant level in the pump housing
Before commissioning, check that there is suffi‐
cient lubricant in the pump housing.
DULCO
®
flex Lubricant
®
, 5 litres, order number
1037254.
Pump
Filling level in litres
DFDa 025
2
DFDa 032
3
DFDa 040
5
DFDa 060
10
DFDa 070
30
DFDa 080
50
DFDa 100
70
DULCO
®
flex Lubricant
®
, 5 litres, order number 1037254
Transport, storage, assembly and Installation