Digital Safe Lock
PLS-2.2
USER MANUAL
www.safe.ru
Ver.1/1 02.02.2022
D
IGITAL
S
AFE
L
OCK
PLS-2.2
USER
MANUAL
1
Main Components
Fig. 1.1
1
– Keypad, 2 – Display, 3 – Cover for emergency
opening, 4
– Turning handle, 5 – Backup power contacts
2
Definitions
2.1
Master Code [PIN1]
A set of 6 numbers which opens and closes the
lock and allows to operate the settings.
Before using the safe, please change the
factory Master code (see par.4). It is strongly
recommended to keep the master code safe
from unauthorized people.
Factory Master Code:
1
–2–3–4–5–6
2.2
User Code [PIN2]
A set of numbers from 4 to 6 digits which
opens/closes the lock and has limited functions to
change the settings. Assigned by the user when the
safe is closed.
A new user code is assigned by the user each time
the safe is closed.
2.3
Signals
[
D]
1
Short single acoustic signal with indication
of the entered character on the display (2)
–
confirmation of the button pressing on the keypad.
You can delete an incorrectly entered character
using the key
«
*
».
[
D]
2
Short double acoustic signal with indication
of the entered character on the display (2)
–
confirmation of successfully finished operation.
[
D]
3
Short triple acoustic signal with indication
«ERROR»
on the display (2)
– error message on the
user’s actions
[
D] Indication
«BA-LO»
on the display (2)
– low
battery message. Please see par.5.2 how to change the
battery
.
3
Main Functions
3.1
Opening the Lock
3.1.1
Opening the New Lock
[#][1][2][3][4][5][6][#]
3.1.2
Opening with Master Code
[#][PIN1][#]
3.1.3
Opening with User Code
[PIN2][#]
If the code is right, there will be indication
«OPEN»
on the display (2) and it will be possible to
open the door within 5 seconds by turning the handle
(4) clockwise.
If you enter a wrong code three times in a row,
the lock will be blocked for 5 minutes. This will
be indicated via
«BLOC»
indication
on the
display (2)
3.2
Closing the Lock
Closing the Lock:
[PIN2][#]
Close the door and turn the handle (4) anti-
clockwise until it stops. There will be
«CLOSED»
indication on the display (2)
If within 5 seconds after entering the code the
mechanism of the locking bolts of the safe is not
activated, the lock will remain open, the code will not
be stored and the closing procedure must be
restarted.
4
Service Functions
It is strongly recommended to change the
settings of the lock with the door opened.
After code changing, the lock shall be tested
several times with the secure stor
age unit’s
door in open state.
The service functions will be unavailable in
case of low power supply which is indicated by
the signals, please refer to par.2.2,
[
D]
.
4.1
Changing the Master Code [PIN1]
[#][#][PIN1][#][new PIN1][#]
[repeat new PIN1][#]
Checking the New Master Code:
[#][new PIN1][#]