Promax PROLITE-20 Скачать руководство пользователя страница 1

INSTRUCTION MANUAL. PROLITE-20/21 

E

nglish

TABLE OF CONTENTS

1

GENERAL .................................................................................................................... 1

1.1

Description.............................................................................................................. 1

1.2

Specifications.......................................................................................................... 1

2

SAFETY RULES .......................................................................................................... 5

2.1

General ................................................................................................................... 5

3

INSTALLATION............................................................................................................ 7

3.1

Power supply .......................................................................................................... 7

3.1.1

Operation using the external DC adapter ........................................................ 7

3.1.2

Operation using the battery.............................................................................. 7

3.1.3

Battery charging ............................................................................................... 8

3.2

Battery installation .................................................................................................. 8

3.3

Installation and start up........................................................................................... 9

4

OPERATING INSTRUCTIONS ................................................................................. 11

4.1

Description of the controls and components ........................................................ 11

4.2

Instrument configuration ....................................................................................... 12

4.2.1

Meter mode .................................................................................................... 14

4.2.2

Acquiring the reference power. (

Set Ref.Level

)............................................. 14

4.2.3

Selecting the wavelength state (

Set WaveLength

) ........................................ 14

4.2.4

Selecting reading display ............................................................................... 15

4.2.5

Speaker configuration (

Speaker

) ................................................................... 15

4.2.6

Display backlight (

BackLight

)......................................................................... 16

4.3

Taking readings .................................................................................................... 16

4.3.1

Measuring Absolute Power ............................................................................ 16

4.3.2

Measuring Relative Power ............................................................................. 17

5

MAINTENANCE ......................................................................................................... 19

5.1

Cleaning Recomendations.................................................................................... 19

5.2

Battery replacement.............................................................................................. 19

Содержание PROLITE-20

Страница 1: ...and start up 9 4 OPERATING INSTRUCTIONS 11 4 1 Description of the controls and components 11 4 2 Instrument configuration 12 4 2 1 Meter mode 14 4 2 2 Acquiring the reference power Set Ref Level 14 4...

Страница 2: ...INSTRUCTION MANUAL PROLITE 20 21...

Страница 3: ...ke them ideal tools for field work The basic difference between the PROLITE 20 and the PROLITE 21 is their measuring range Whereas the PROLITE 20 measures power between 50 dBm and 25 dBm for the diffe...

Страница 4: ...E 20 from 30 dBm to 25 dBm PROLITE 21 from 50 dBm to 5 dBm POWER SUPPLY Battery 7 2 V 950 mAh Ni Cd battery Low battery indication LB flashes at the far right of the display Autonomy Typically 30 h wi...

Страница 5: ...2 Car lighter adapter cable 1x AL 013 EUROPE and other countries 230 V 50 60 Hz mains power adapter 1x AL 023 USA and CANADA 120 V 50 60 H mains power adapter only with the OPT 01 1x CB 038 Rechargeab...

Страница 6: ...INSTRUCTION MANUAL PROLITE 20 21 Page 4 February 2001...

Страница 7: ...and measurement Remember that voltages higher than 60 V DC or 30 V AC rms are dangerous Use this instrument under the specified environmental conditions The user is only authorised to carry out the fo...

Страница 8: ...lated with safety DIRECT CURRENT ALTERNATING CURRENT DIRECT AND ALTERNATING GROUND TERMINAL PROTECTIVE CONDUCTOR FRAME TERMINAL EQUIPOTENTIALITY ON Supply OFF Supply DOUBLE INSULATION CLASS II protect...

Страница 9: ...nnect the DC adapter to the mains thereby starting the battery charging process Next press the start stop button 4 on the PROLITE 20 21 Under these conditions the instrument starts to function Battery...

Страница 10: ...tery installation Only use CB 038 batteries To install the battery place it on the base of the arrows at the rear of the instrument Slide it in until you hear a click and the battery is secured as sho...

Страница 11: ...nstrument and the software version E g in the case of the PROLITE 21 Figure 3 A fully charged battery will power the instrument for some thirty hours if the display is not illuminated The battery shou...

Страница 12: ...INSTRUCTION MANUAL PROLITE 20 21 Page 10 February 2001...

Страница 13: ...February 2001 INSTRUCTION MANUAL PROLITE 20 21 Page 11 English 4 OPERATING INSTRUCTIONS 4 1 Description of the controls and components Front panel Figure 4 Front View...

Страница 14: ...peaker 7 Display contrast control 8 Exterior power supply and charging input 4 2 Instrument configuration The configuration screen enables the following parameters to be modified Selects the active me...

Страница 15: ...on menu when the instrument is on keep the rotary selector pressed down a few seconds until the configuration menu appears you will hear a second beep To leave the configuration screen turn the rotary...

Страница 16: ...ow the acquisition is proceeding If you stop pressing the rotary selector during the measurement process the process halts and the instrument continues to use the previous reference value 4 2 3 Select...

Страница 17: ...wavelength or the meter mode Only the configuration menu options corresponding to the graphic display and the backlight can be changed The configuration menu options available in this display mode ca...

Страница 18: ...he PROLITE 20 21 has two meter modes the Absolute Power Meter mode and the Relative Power Meter mode 4 3 1 Measuring Absolute Power In this meter mode the instrument measures absolute power in dBm at...

Страница 19: ...Power Meter Mode or Relative Mode in the case of Relative Power Meter Mode Select the relative mode by pressing the rotary selector Relative Mode will appear on the display and proceed to obtaining t...

Страница 20: ...INSTRUCTION MANUAL PROLITE 20 21 Page 18 February 2001...

Страница 21: ...d in the constructions of the cover The cover should be cleaned by means of a light solution of detergent and water applied with a soft cloth Dry thoroughly before using the system again CAUTION The c...

Страница 22: ...INSTRUCTION MANUAL PROLITE 20 21 Page 20 February 2001...

Отзывы: