background image

PROLIGHTS - StudioCob  

PFC2

21

Problems

Possible causes

Checks and remedies

Product doesn’t power ON •  No power to the 

product.

•  Check that power is switched ON and cables are 

plugged in.

•  Fuse blown or internal 

fault.

•  Check if the Fuse is intact and eventually replace it if 

necessary.

• 

Contact the PROLIGHTS Service or authorized service 

partner. Do not remove parts and/or covers, or carry 

out any repairs or service that are not described in 

this  Safety  and  User  Manual  unless  you  have  both 

authorization  from  PROLIGHTS  and  the  service 

documentation.

Product reset correctly but 

does not respond correctly 

to the contoller.

• 

Bad signal connection.

•  Inspect connections and cables. Fix eventual bad 

connections. Repair or replace damaged cables.

•  Signal connection not 

terminated.

• 

Insert DMX termination plug in signal output socket of 

the last product on the signal line.

•  Incorrect addressing of 

the product.

•  Check the product address and control settings.

•  One of the product is 

defective and is corrupt

-

ing the signal transmis

-

sion on the signal line.

• 

Unplug  the  XLR  in  and  out  connectors  and  connect 

them directly together to bypass one product at a 

time until normal operation is regained. Once found 

the  error,  have  that  fixture  serviced  by  a  qualified 

technician.

Timeout error after fixture 

reset.

•  One or more hardware 

components requires 

mechanical adjustments

•  Check product stored error messages for more 

information. Contact PROLIGHTS Service or an 

authorized service partner.

Mechanical effect loses 

position

• 

Mechanical 

hardware 

require cleaning, adjust

-

ment or lubrification.

•  Check product stored error messages for more 

information. Contact PROLIGHTS Service or an 

authorized service partner.

Light output turn OFF 

Intermittently

•  Fixture is too hot.

•  Check product stored error messages.

•  Allow product to cool.

• 

Clean the product and airflow filters.

•  Reduce ambient temperature.

•  Hardware failure (tem

-

perature sensor, fans, 

Light source...).

•  Check product stored error messages for more 

information. Contact. PROLIGHTS Service or an 

authorized service partner.

General low light intensity

•  Dirty lens assembly.

• 

Dirty or damaged filters.

• 

Clean the fixture regularly.

•  Install lens assembly properly.

Contact an authorized service center in case of technical problems or not reported in the table can not 

be resolved by the procedure given in the table.

TROUBLESHOOTING

Содержание StudioCob PFC2

Страница 1: ...USER MANUAL English version StudioCob PFC2 150W IP65 rated full colour COB LED Par REV 01 09 21...

Страница 2: ...conomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights...

Страница 3: ...LINE 09 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 09 CONNECTION DAISY CHAIN 09 CONNECTION OF THE DMX LINE 09 CONSTRUCTION OF THE DMX TERMINATION 10 DMX ADDRESSING 10 8 CONTROL PANEL 11 DISPLAY AND B...

Страница 4: ...ments of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover cable or other components are damaged defective deformed or showing signs of overheating D...

Страница 5: ...ace of the fixture can reach up to 60 C 140 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10...

Страница 6: ...electrical equipment supplied at low voltage LVD 2014 30 EU Electromagnetic Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS Other approvals The product meets...

Страница 7: ...ocket L 3m C6002 slim aluminium clamp 200 kg loading 48 51 mm tubes M10 bolt RSR0630A B steel security cable for hanging bodies inox steel shackle L 60 cm silver black STUDIOCOBPLUSL18 optics for STUD...

Страница 8: ...imary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak ancho...

Страница 9: ...er from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switc...

Страница 10: ...t 4 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 5 POWER IN for connection to the Mains 100 240V 50 60Hz 6 USER INTERFACE with display and buttons for access to the control panel functions 7 DMX OUT...

Страница 11: ...e connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male conne...

Страница 12: ...be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the...

Страница 13: ...r access to the control panel functions MENU used to access the menu tree or to return a previous menu window UP browse upwards through the menu list and increases the numeric value displayed DOWN bro...

Страница 14: ...0 255 4 Auto Show Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Speed 0 100 Speed 0 100 Speed 0 100 Speed 0 100 Speed 0 100 5 Master Slave Master Slave Allow you to link and operating in synk multiple units wit...

Страница 15: ...ctive 11 Key Lock On Of Allows you lock the buttons on the control panel by a password Press following com binations password in order to access to the user menu UP DOWN UP DOWN ENTER 12 Information F...

Страница 16: ...1 x x Power Lamp Settings DEVICE_HOURS 0x0400 x x LAMP_HOURS 0x0401 x x LAMP_STRIKES 0x0402 x x Display Settings DISPLAY_INVERT 0x0500 x x Control IDENTIFY_DEVICE 0x1000 x x 10 RDM FUNCTIONS The produ...

Страница 17: ...h 4 Ch 6 Ch 10 Ch 1 RED DIMMER DIMMER 2 GREEN RED RED 3 BLUE GREEN GREEN 4 WHITE BLUE BLUE 5 WHITE WHITE 6 STROBE STROBE 7 COLOR FUNCTION 8 COLOR PRESETS WHITE PRESETS COLOR MACRO 9 COLOR MACRO SPEED...

Страница 18: ...100 100 RGB 0 100 0 100 RGB 100 0 0 100 RGB 100 0 100 0 100 RGB 0 100 0 100 100 RGBW 100 100 100 100 WHITE PRESETS active when Color function is on White presets RGBW 2000K 3000K RGBW 3000K 4000K RGBW...

Страница 19: ...er using the four screws to the four holes on the front cover of the unit 2 C A B DETAIL Push the pin A and open upward the gel frame lock B Insert the filter frame C from above into the guides DETAIL...

Страница 20: ...ur holes on the front cover of the unit 2 C A B DETAIL Push the pin A and open upward the frame lock gel B Insert the barn doors C into from above by inserting the linking holders into the guides DETA...

Страница 21: ...A washer B front cover C glass lens D filter E Insert the optic by replacing the one already present and follow the reverse procedure to reassemble the parts NOTE To remove the accessory reverse the p...

Страница 22: ...other service operations on the product must be carried out by PROLIGHTS its approved service agents or trained and qualified personnel It is PROLIGHTS policy to apply the strictest possible calibrat...

Страница 23: ...ctors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error afte...

Страница 24: ...Note...

Страница 25: ...Note...

Страница 26: ...Note...

Страница 27: ......

Страница 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: