ProLights EclProfile FW Скачать руководство пользователя страница 16

PROLIGHTS - Ecl 

FW

14

9 - MENU STRUCTURE 

The following chart describes the MENU tree of the product, the terms shown in 

BOLD

 indicates the 

default settings.

MENU

1 Connect

DMX Address

Value (001-

512)

DMX Mode

UNO
Basic

Standard

Extended

2 Setup

Backlight

On

10 s

20 s

30 s

Allows  you  to  select  the  timing  after  that 

display will switch automatically off when 

unactive.

Flip Display

On

Off

Allows you to rotate the display by 180°.

Disp. Lock

On

Off

Allows you lock the buttons on the control 

panel  by  a  password.  Press  following 

combinations (password) in order to access 

to the user menu : UP, DOWN, UP, DOWN, 

ENTER,

Transfer

Configuration

No DMX Add.

DMX Add.

To transfer the same menu settings of one 

fixtures to all the other in the daisy chain, 

including or not the dmx address.

Temperature 

Unit

°C

°F

To choose the desired unit of temperature 

measurement.

3 Advanced

Dimmer Curve Linear

S-Curve

Sqr Law

Inv. Sqr Law

To choose the dimmer curve.

Dimmer 

Speed

Auto

Fast

Medium

Slow

To choose the dimmer speed.

Led Frequency

600 Hz

1200 Hz

2000 Hz

4000 Hz

6000 Hz

25 KHz

Select PWM frequency.

Fan Mode

Auto

Silent

Full

Off

Select the product Fan mode.

DMX Lost

Blackout

Hold

Stand Alone

To choose the behaviour of fixture in case 

of dmx signal lost.

4 Stand Alone

Master / Slave Master

Slave

Allow  you  to  link  and  operating  in  sync 

multiple units without a DMX console. 

Choose  a  unit  to  perform  as  the  Master. 

This unit must be the first unit in line; Set

the successive units to be slave.

Preset

Dimmer

Dimmer Fine

Dimmer 

Speed

Strobe

To adjust the preset values for the unit.

Содержание EclProfile FW

Страница 1: ...USER MANUAL REV 02 12 20 English version EclProfile FW High quality Full White LED ellipsoidal available in Tungsten and Daylight versions...

Страница 2: ...economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolight...

Страница 3: ...ON OF THE DMX TERMINATION 12 DMX ADDRESSING 12 8 CONTROL PANEL 13 DISPLAY AND BUTTONS LAYOUT 13 9 MENU STRUCTURE 14 10 RDM FUNCTIONS 16 11 SHORTCUTS 17 12 ERROR MESSAGES 17 13 DMX CHARTS 18 14 ACCESSO...

Страница 4: ...e in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components are dam...

Страница 5: ...id and particle build up degrades performance causes overheating and will damage the fixture Damages caused by inadequate cleaning or maintenance are not covered by the product warranty T 70 C c Tempe...

Страница 6: ...luminaire at a distance closer than 3 72 m is not expected Disposal This product is supplied in compliance with European Directive 2012 19 EU Waste Electrical and Electronic Equipment WEEE To preserv...

Страница 7: ...15 30 PRL lens barrel for EclProfile fixtures black housing ECLPRLZ2550BK zoom 25 50 PRL lens barrel for Ecl Profile fixtures black housing ECLLZ1530 optics for ECLFC HD ECLFS ECLFW ECLCTPLUS profile...

Страница 8: ...Ecl FW 06 2 TECHNICAL DRAWING Weight 7 3 kg 16 09 lbs ECLFW without optic Weight 10 2 kg 22 48 lbs ECLFW with ECLPRL05 Weight 9 2 kg 20 28 lbs ECLFW with ECLPRL10 Weight 10 6 kg 23 37 lbs ECLFW with...

Страница 9: ...lbs ECLPRL26 9 7 21 38 lbs ECLPRL36 9 4 20 72 lbs ECLPRL50 9 1 20 06 lbs ECLFW with ECLPRL19 26 36 50 Weight 9 1 kg 21 06 lbs ECLFW with ECLPRL70 Weight 11 3 kg 24 91 lbs ECLFW with ECLPRLZ1530 Weigh...

Страница 10: ...re it against failure of primary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use re...

Страница 11: ...rom the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switching...

Страница 12: ...to attach safety cable 8 HANDLE 9 USER INTERFACE with display and buttons for access to the control panel functions 10 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 11 DMX OUT 5 p XLR 1 GND 2 sign 3...

Страница 13: ...onnection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male connecto...

Страница 14: ...xecuting the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the DMX...

Страница 15: ...ns for access to the control panel functions MENU Used to access the menu tree or to return a previous menu window UP Browse upwards through the menu list and increases the numeric value displayed DOW...

Страница 16: ...ngs of one fixtures to all the other in the daisy chain including or not the dmx address Temperature Unit C F To choose the desired unit of temperature measurement 3 Advanced Dimmer Curve Linear S Cur...

Страница 17: ...is chase into play by putting the switch on For each scene you can set fade time and hold time Mix 16 Switch Hold Time Fade Time Dimmer On Off On 5 Information Fixture H To view infromation about the...

Страница 18: ...ESPONSE_TIME 0x0345 x x OUTPUT_RESPONSE_TIME_ DESCRIPTION 0x0346 x MODULATION_FREQUENCY 0x0347 x x MODULATION_FREQUENCY_ DESCRIPTION 0x0348 x Sensors SENSOR_DEFINITION 0x0200 x SENSOR_VALUE 0x0201 x x...

Страница 19: ...12 ERROR MESSAGES 11 SHORTCUTS LAMP_STATE 0x0403 x x LAMP_ON_MODE 0x0404 x x DEVICE_POWER_CYCLES 0x0405 x x Display Settings DISPLAY_INVERT 0x0500 x x DISPLAY_LEVEL 0x0501 x x Configuration LOCK_PIN 0...

Страница 20: ...Y 20S DISPLAY 30S FLIP DISPLAY ON FLIP DISPLAY OFF KEY LOCK ON KEY LOCK OFF DIMMER CURVE LINEAR DIMMER CURVE S CURVE DIMMER CURVE SQUARE LAW DIMMER CURVE INVERSE SQUARE LAW DIMMER SPEED AUTO DIMMER SP...

Страница 21: ...PROLIGHTS Ecl FW 19 14 ACCESSORIES INSTALLATION OPTIC CODE ECLPRL OPTIONAL 1 Loosen and remove the two marked knobs 2 Mount the desired optic 3 Insert and tighten the knobs Fig 8...

Страница 22: ...ONAL 1 2 1 Push the clip located at the top of the optics body outwards 1 and lift it 2 1 2 3 2 Then insert the filter 1 into the marked track 2 and close the clip 3 always applying an outward push NO...

Страница 23: ...PROLIGHTS Ecl FW 21 GOBO HOLDER CODE ECLPRGH OPTIONAL Gobo dimensions Type B external 86 mm of image 64 5 mm Thinckness 1 1 mm 86 3 4 65 2 5 1 1 0 04 Put in place the Gobo Fig 10...

Страница 24: ...2 1 1 Loosen the marked screws 1 Then open the slot of the middle part 2 1 2 2 Insert the gobo holder 1 into the slot The flaps will go into the appropriate size 2 NOTE To remove the accessory reverse...

Страница 25: ...PRIRIS OPTIONAL 1 2 1 1 Loosen the marked screws 1 Then open the slot of the middle part 2 1 2 2 Insert the steel iris diaphram 1 into the slot The flaps will go into the appropriate size 2 NOTE To re...

Страница 26: ...OFT EDGE FILTER CODE ECLPRSEF1 OPTIONAL 1 2 1 1 Loosen the marked screws 1 Then open the slot of the middle part 2 1 2 Insert the Soft edge filter into the slot 1 NOTE To remove the accessory reverse...

Страница 27: ...4 3 1 Loosen the marked knob 1 and screw 2 Then rotate 3 the middle part and remove it 4 1 2 3 2 Insert the soft focus diffusion kit by placing the magnets 1 on the back of the framing system 2 of th...

Страница 28: ...E POLE OPERATED YOKE CODE ECLPRPOYO OPTIONAL 1 Loosen and remove the marked screws 2 Remove the bracket 3 Mount the Pole Operated Yoke bracket 4 Tighten the screws NOTE To remove the accessory reverse...

Страница 29: ...personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component li...

Страница 30: ...s and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fi...

Страница 31: ...Note...

Страница 32: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: