12 VOLT 30 AMP AUTOMATIC

P/No. SC030

SOLAR CHARGE CONTROLLER

Содержание SC030

Страница 1: ...12 VOLT 30 AMP AUTOMATIC P No SC030 SOLAR CHARGE CONTROLLER ...

Страница 2: ...o cover the front face of the panel s with a soft cloth to block incoming light during installation For use with 12V nominal solar panels For indoor out of weather use only Do not exceed the total limit of the solar controller 360W 30A FEATURES 3 STAGE CHARGING Ideal for deep cycle batteries the SC030 delivers 3 stage charging maximising battery life and performance Maintains your battery ready fo...

Страница 3: ...olt battery array not present BATTERY CONDITION DISPLAY LED light indicated range LOW red 11 5 0 4 FAIR yellow 11 5 to 12 5 0 4 GOOD green 12 5 0 4 LCD Meter Accuracy DC voltage 1 25 LCD Meter Accuracy DC current 3 PROTECTION Over temperature protection engages at 80 C 176 F stop charging Over temperature protection resets at 65 C 149 F restart charging Operation Temperature from 5 to 50 C 23 to 1...

Страница 4: ...ING DIAGRAM Connection Procedures please refer to the connection diagram above 1 Once the controller has been properly mounted select either Gel or Wet modes on the unit 2 Connect the solar panel positive side to the charge controller ARRAY positive with a suitable wire Be careful not to short circuit the solar array 3 Connect the solar panel negative side to the charge controller ARRAY negative w...

Страница 5: ...ll indicate the battery condition in three states GOOD green FAIR yellow LOW red Please refer to label Please note the charge controller is not able to start the charging process if the initial battery voltage is less than 3 volts 0 3 CHARGING STATUS INDICATOR L E Ds The top 3 LED indicator lights show the charging status of the charge controller The red LED indicates solar power available ON indi...

Страница 6: ... indicates the battery voltage is less than 11 5V The red LED will blink if battery is disconnected from the unit The charge controller will not function if not connected to both the battery as well as the solar array Testing may not be performed while the charge connector is unhooked from one or both of the batteries or solar array When Solar Power is weak as well as during the night the charger ...

Страница 7: ...nd battery may also be added to the existing battery by wiring the additional battery in parallel to the existing battery The charge controller only needs to be connected to one of the batteries in this case The battery may be bad Small level of charge or discharge will greatly affect the battery voltage Battery needs replacing Wires may be incorrectly hooked to the charge controller Ensure the wi...

Страница 8: ...urchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion In the event that a major failure is determined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable l...