background image

P/No. PM200-BTJ & PM235J-NODE

PM235J Transformer Unit

Phone App

PMBTJ-02 Bluetooth Node  
(PM235J-NODE system only)

PMLCD-BTJ LCD Screen  
(PM200-BTJ system only)

Need technical help? 
Contact Projecta on 1800 294 294

12V POWER MANAGEMENT SYSTEM

INTELLI

Содержание IntelliJay PM200-BTJ

Страница 1: ...J NODE PM235J Transformer Unit Phone App PMBTJ 02 Bluetooth Node PM235J NODE system only PMLCD BTJ LCD Screen PM200 BTJ system only Need technical help Contact Projecta on 1800 294 294 12V POWER MANAG...

Страница 2: ...ional wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If theAC cord is damaged do not attempt to use It must be replaced or repaired by a qualified techn...

Страница 3: ...robe 11 3 3 2 PMWS200 water tank probe 11 4 WIRING 12 4 1 Material 12 4 2 System schematic 13 4 3 Preparation 14 4 4 Connection 14 5 DISPLAY 15 5 1 PM235JTransformer Unit 16 5 2 LCD monitor PM200 BTJ...

Страница 4: ...th an Bluetooth enabled LCD screen PMLCD BTJ allowing a user to monitor and control the system via the LCD or the Bluetooth app PM235J NODE does not come with an LCD screen instead utilising a separat...

Страница 5: ...surement 1 water pump control with up to 4 connections for water sensors Thermal control fan Spring terminal and screw terminal T bus compatible Figure 2 System Schematic LOAD14 for Compressor Fridge...

Страница 6: ...tures a Microprocessor controlled charging algorithm The Float and Recycle charging programs guarantees that the battery condition does not change despite being connected for a longer period 1 2 LCD M...

Страница 7: ...e s power plug from the caravan If the VCR is still engaged press the PWR button on the LCD or app ON OFF ON LEADACID BATTERY When the vehicle battery reaches 13 4VDC with threshold time delay theVCR...

Страница 8: ...nt can be measured and read accurately with this device With this feature it highlights faults alarms and installation errors NOTE If you have loads connected directly to the battery instead of throug...

Страница 9: ...attery 10 Solar Solar input Connect to solar panel terminal 11 Solar Solar input Connect to solar panel terminal 12 Vehicle Bat Vehicle battery Connect to vehicle battery 20Vdc 13 House Bat House batt...

Страница 10: ...be installed on a horizontal surface or vertically on a wall Please see following instructions Figure 10 Installation of PM235J Unit mm Ensure clearance on both sides of PM235J unit upon installation...

Страница 11: ...mm 3 3WaterTank Probes 3 3 1 PMWS400WaterTank Probe Figure 13 Dimension of PMWS400 Unit mm Figure 14 Installation of PMWS400 3 3 2 PMWS200WaterTank Probe Installation Figure 15 Dimension of PMWS200 Un...

Страница 12: ...7 7 Solar 0 9 10 Communication line RS485 10m 1 PMLCDC 10 11 Temperature line 5m 1 PMTS 12 Battery sensor line 3m 1 PMBS 13 Water tank probe line Not included 0 PMWS200 PMWS400 14 Water tank probe lin...

Страница 13: ...r Waste Water Tank Level Sensor N L AC IN Monitor Switch Panel Battery Sensor Waste Water Tank Tap Water Tank Fresh Water Tank 2 Fresh Water Tank 1 L12 L13 L14 L14 L13 L12 L11 L10 L9 L8 L7 L6 L5 L4 L3...

Страница 14: ...5 10A 2 0mm2 or 14AWG 10 15A 3 0mm2 or 13AWG 15 20A 4 0mm2 or 11AWG 20 25A 5 0mm2 or 10AWG 25 30A 6 0mm2 or 9AWG Table 5 Minimum cable size Table 6 Recommended terminal and cable gauge Figure 18 PM23...

Страница 15: ...mal but it is charged by theAC or vehicle battery Quick flashing flash twice every second Solar input voltage error Solar voltage 25Vdc OFF Solar disconnected 4 CHG GREEN ON Battery charged Slow flash...

Страница 16: ...charging relay VCR is connected Voltage charging relay VCR is disconnected 7 Output power Voltage of system output Current of system output Table 8 Symbol Explanation Charging state Pump Up switch Hot...

Страница 17: ...n for 10 seconds PUMP To switch on off pump Refer Figure 24 PWR To switch off all the loads connected on DC charger Refer Figure 25 DIM To adjust the brightness and switch off the backlight of he moni...

Страница 18: ...ine Press the DIM button until the setting code is showing on the date time area which means the monitor is ready for configuration The PUMP button and PWR button can be used to scroll through the con...

Страница 19: ...e and Time setting Figure 33 Check firmware version Setyear Setmonth Setdate Set12 houror24 hour Sethour Setminute SelectAGMbattery SelectGELbattery SelectLFPbattery SelectWETbattery Disabletoupdatefi...

Страница 20: ...on To do this tap the white settings cog gear down the bottom of the screen Note depending on your device you may need to scroll to reveal this menu Tap the down arrow under Type Choose your battery t...

Страница 21: ...ERROR CODE DESCRIPTION 8001 Lose communication 8003 Loss of communication 8004 Battery voltage high 8005 Solar voltage low 8006 Solar voltage high 8010 Battery temperature high 8011 Battery temperatur...

Страница 22: ...output current 35A Continuous Efficiency 88 Working temperature 40 C 65 C 50 C full load 60 C 20A 65 C shutdown the output MODEL PM235J ELECTRICAL SPECIFICATIONS Battery Disconnect LVD Disconnect volt...

Страница 23: ...23 Notes...

Страница 24: ...of purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to rep...

Отзывы: