e.  Please move clockwise all the volume knobs to increase output levels,  

counter-clockwise to reduce output levels.   

 

 

Warning: 

before connecting and/or disconnecting any sound source to 

this unit, in order to avoid forthcoming units damages please make sure 
that the output knobs are set totally counter-clockwise.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical Specifications  

 

Model 

ADIS5 

Input connectors  

2 balanced line level female XLR  

Input sensitivity/impedance

0,775V/15K

  

Output connectors  

10 balanced line level male XLR  

Output level/impedance 

0,775V/600K

  

Frequency response  

50Hz~20KHz > -0,5dB 

Signal-to-noise ratio 

< 90dB 

AC power supply  

115-120 / 220-230V  60 / 50Hz  

Power consumption  

6W 

Dimensions  

1U standard 19” 

Dimensions (WxHxD) 

483x44x213 (mm) 19 in x1.75 in x 8.4 in

Weight 

3  Kg. – 6.6<gd lbs 

 

Содержание ADIS5

Страница 1: ...USER S MANUAL AUDIO DISTRIBUTOR ADIS5...

Страница 2: ...ting and maintenance servicing instruction in the literature accompanying the appliance Please carefully read the owner s manual INSTRUCTIONS All safety and operating instructions should be read befor...

Страница 3: ...ower source type specified in this owner s manual or on the unit If the supplied AC power cable plug is different from wall socket please contact an electrician to change the AC power plug Grounding o...

Страница 4: ...in fire or electric shock Damages requiring services Don t attempt to do operations not described in this user s manual In the following cases please refer to an authorized maintenance center or skill...

Страница 5: ...s over the unit In case of interferences from source signal THD value will raise over 10 Don t place this unit in a bookshelf o in other places with small room PROEL S P A is not responsible for any d...

Страница 6: ...t level controls for CH1 and CH2 sections Rear panel description 1 IEC standard AC power supply socket 2 Fuse holder 3 AC power selector 4 Section CH1 and CH2 output connections 5 CH1 and CH2 input co...

Страница 7: ...ition the unit distributes CH1 input signal to 5 CH1 section outputs and CH2 to 5 CH2 section outputs With this selector fig 1 ref 3 in MONO position the unit distributes CH1 signal only to 10 outputs...

Страница 8: ...are set totally counter clockwise Technical Specifications Model ADIS5 Input connectors 2 balanced line level female XLR Input sensitivity impedance 0 775V 15K Output connectors 10 balanced line level...

Страница 9: ...ards EN 50082 1 1997 EN 55013 1990 EN 55020 1994 it is also in compliance with Directive 73 23 EEC Low Voltage and following modifications 93 68 EEC as the following standard EN 60065 1998 Proel SpA p...

Страница 10: ...PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 811241 Fax 39 0861 887862 E mail info proelgroup com installation proelgroup com...

Отзывы: